34th Annual International Conference of the IEEE EMBS

Slides:



Advertisements
Similar presentations
Estimation of TLD dose measurement uncertainties and thresholds at the Radiation Protection Service Du Toit Volschenk SABS.
Advertisements

Slide Ruler. ? X 5" On today’s menu...  What happened with Gravity  Noise  The tool today  Fundamental Limitations  Magical Christmas Land  (Where.
Instructor Terry Wiseth
Robust Object Segmentation Using Adaptive Thresholding Xiaxi Huang and Nikolaos V. Boulgouris International Conference on Image Processing 2007.
Monitoring of Activity Levels of the Elderly in Home and Community Environments using Off the Shelf Cellular Handsets Initial Presentation by Martin Newell.
T T18-05 Trend Adjusted Exponential Smoothing Forecast Purpose Allows the analyst to create and analyze the "Trend Adjusted Exponential Smoothing"
Department of Computer Science and Engineering (CSE), BUET
Effects of exercise on the cardiovascular system 1 Effects of exercise on the cardiovascular system.
Energy-efficient Self-adapting Online Linear Forecasting for Wireless Sensor Network Applications Jai-Jin Lim and Kang G. Shin Real-Time Computing Laboratory,
Reliability of Selection Measures. Reliability Defined The degree of dependability, consistency, or stability of scores on measures used in selection.
Design and Development of an Accelerometer based Personal Trainer System By Emer Bussmann B.E. Electronic Engineering April 2008.
1 QRS Detection Section Linda Henriksson BRU/LTL.
FDR Presentation Personal Health Monitoring Device Bassam Noaman Dina El-Eissa Mentor: Prof Zhenyu Guo Instructor: Prof J Silverman 4/12/00.
Exercise & Heart Rates Parts of a Workout & THR. Exercise & Heart Rates ▪ Parts of a Workout (review) ▪ Heart Rates and Beats per Minute.
Presenter : Chung-Yi Chiu Date : April 23th An Overview of Technologies Related to Care for Venous Leg Ulcers Meghan Sarah Hegarty, Student Member, IEEE,
Artifacts In Wearable Photoplethysmographs During Daily Life Motions and Their Reduction With Least Mean Square Based Active Noise Cancellation Method.
Motion-Tolerant Magnetic Earring Sensor and Wireless Earpiece for Wearable Photoplethysmography Ming-Zher Poh, Student Member, IEEE, Nicholas C. Swenson,
南台科技大學 資訊工程系 Posture Monitoring System for Context Awareness in Mobile Computing Authors: Jonghun Baek and Byoung-Ju Yun Adviser: Yu-Chiang Li Speaker:
TIME SERIES by H.V.S. DE SILVA DEPARTMENT OF MATHEMATICS
Real-Time Phase-Stamp Range Finder with Improved Accuracy Akira Kimachi Osaka Electro-Communication University Neyagawa, Osaka , Japan 1August.
1 A Portable Tele-Emergent System With ECG Discrimination in SCAN Devices Speaker : Ren-Guey Lee Date : 2004 Auguest 25 B.E. LAB National Taipei University.
Estimate of Swimming Energy Expenditure Utilizing an Omnidirectional Accelerometer and Swim Performance Measures Jeanne D. Johnston and Joel M. Stager,
Analysis of Photoplethysmographic Signals Modified by Reversible Watermarking Technique using Prediction-Error in Wireless Telecardiology Presented by.
Extracting Barcodes from a Camera-Shaken Image on Camera Phones Graduate Institute of Communication Engineering National Taiwan University Chung-Hua Chu,
Automatic Ballistocardiogram (BCG) Beat Detection Using a Template Matching Approach Adviser: Ji-Jer Huang Presenter: Zhe-Lin Cai Date:2014/12/24 30th.
An Information Fusion Approach for Multiview Feature Tracking Esra Ataer-Cansizoglu and Margrit Betke ) Image and.
Department of Computer and Electrical Engineering A Study of Time-based Features and Regularity of Manipulation to Improve the Detection of Eating Activity.
Scientific Method A systematic approach to problem solving.
Doppler Ultrasound Dr Mohamed El Safwany, MD.. Introduction The Doppler Effect refers to the change in frequency that results when either the detector/observer.
The Doppler Effect.
Linear Kinematics of Human Movement
Waves How do we see color?
1.4 Wrist-Worn Wellness Watch Tom Honeywill Vadim Melnikov Grace Fuller.
Halftoning With Pre- Computed Maps Objective Image Quality Measures Halftoning and Objective Quality Measures for Halftoned Images.
IEEE JOURNAL OF SOLID-STATE CIRCUITS, VOL. 50, NO. 3, MARCH 2015 Woojae Lee, Member, IEEE, and SeongHwan Cho, Senior Member, IEEE Chairman: Dr.Shih-Chung.
Quality Control: Analysis Of Data Pawan Angra MS Division of Laboratory Systems Public Health Practice Program Office Centers for Disease Control and.
Exercise & Heart Rates Parts of a Workout, FITT Principle & THR.
Turning a Mobile Device into a Mouse in the Air
Speaker: Sun Peng Identifying Drug (Cocaine) Intake Events from Acute Physiological Response in the Presence of Free-living Physical Activity.
Statistics: Unlocking the Power of Data Lock 5 Inference for Means STAT 250 Dr. Kari Lock Morgan Sections 6.4, 6.5, 6.6, 6.10, 6.11, 6.12, 6.13 t-distribution.
Copyright © 2009 Pearson Education, Inc., publishing as Benjamin Cummings Blood Vessels: The Vascular System  Transport blood to the tissues and back.
Contents Introduction Requirements Design Technology Working Interaction.
Lecture 9 Forecasting. Introduction to Forecasting * * * * * * * * o o o o o o o o Model 1Model 2 Which model performs better? There are many forecasting.
Assessment of data acquisition parameters, and analysis techniques for noise reduction in spinal cord fMRI data  R.L. Bosma, P.W. Stroman  Magnetic Resonance.
1 Figure 1: Patient Setup and Sample VENDYS DTM Report
Heart Rate.
Comparison of Sensor Analysis for Swimming in Different Positions
Heart Rate Blood Pressure
QRS Detection Linda Henriksson 1.
Linear Kinematics of Human Movement
Andrew mortallero, Irene ng January 23, 2014
Posture Monitoring System for Context Awareness in Mobile Computing
Sample Size Estimation
Linear Kinematics of Human Movement
Hyonyoung Han, Min-Joon Kim, and Jung Kim
Choice of Methods and Instruments
The Coefficient of Determination (R2) vs Relative Standard Error (RSE)
T18-08 Calculate MAD, MSE Purpose Allows the analyst to create and analyze the MAD and MSE for a forecast. A graphical representation of history and.
Inferential Statistics
Chapter 7: Statistical Issues in Research planning and Evaluation
Volume 4, Issue 2, (February 2007)
Diagnostics and Remedial Measures
A prospective comparison of bilateral photoplethysmography versus the ankle-brachial pressure index for detecting and quantifying lower limb peripheral.
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Motion Measuring Motion Motion Speed & Velocity Acceleration
Effect of Sample size on Research Outcomes
Application of Optical Heart Rate Monitoring
BATCH ANALYSIS TOOL FOR E4 DATA
Mole: Motion Leaks through Smartwatch Sensors
Presentation transcript:

Estimating Heart Rate using Wrist-Type Photoplethysmography and Acceleration Sensor while Running 34th Annual International Conference of the IEEE EMBS San Diego, California USA, 28 August - 1 September, 2012 Hayato Fukushima, Haruki Kawanaka, Md. Shoaib Bhuiyan and Koji Oguri

Introduction Monitoring heart rate during movement is important for preventing accidents caused by heart troubles. This paper’s purpose is estimating heart rate while actual running is being occurred, using Photoplethysmography (PPG) wrist-type sensor. The arm portion is greatly affected by movement artifacts, and the waveform of PPG is easy to be distorted by body motion artifacts. Estimation heart rate in this paper is using accelerometer to improve the accuracy of heart rate measurement.

Photoplethysmography PPG is the change of blood’s volume in the capillary vessel. PPG can observed noninvasively with irradiating LED toward the capillary vessel in the skin, and receiving the reflected light at PD.

PPG is greatly affected by movement artifacts, the artifact caused by the runner shaking arm convolutes into PPG. Such artifact is periodic, and the frequency of the artifact is close to that of heart rate.

Outline of Heart Rate Estimation Algorithm In this study, defined the following three states (resting, warming up, running) from the magnitude of the measured acceleration amount. In each of these three states, the time and force of arm movement is different, so the estimation method can use the acceleration’s integral absolute value (it has both positive and negative values) as a threshold to determine each of the above three states.

Estimation using Frequency Analysis Accelerometer used to reject the artifact of shaking arm. The artifact caused by motion appears in acceleration as well as in PPG. Frequency sequences Xppg (f), Xacc(f) are calculated by frequency analysis from PPG and acceleration respectively

The frequency of heart rate detected in the frequency sequence D(f) The frequency of heart rate detected in the frequency sequence D(f). D(f) is the difference of spectrum between PPG to Acceleration, defined as The frequency whose spectrum is maximum in D(f) is accepted as heart rate. With this method, heart rate frequency fHR can be detected, and the artifact of shaking arms can also be rejected.

Method for Aperiodic Motion While in aperiodic movement such as warming up, artifacts can’t be detected in frequency sequences Xppg (f), Xacc(f) as clear peaks. The relative reliability to estimate is defined by measured acceleration. The reliability as coefficient is calculated by acceleration (i) which is acceleration at i, in seconds. Reliability (i) is defined as

Heart rate frequency fHR estimated with weighted smoothing the instantaneous heart rate frequency fpeaks (i) The instantaneous heart rate frequency fpeaks (i) is calculated by the difference of the time PPG’s peaks happen.

Post-Processing Smoothing filter at the postprocessing used to reject outliers, caused by motion artifacts having huge magnitude. n = 120 second used to calculate σ(i) and fav(i) at the time i, in seconds. σ(i) is defined as fav(i) is the average of heart rate frequency, and the standard deviation is σ(i). Heart rate frequency is f(i).

If the difference between f(i) to fav(i) is greater than σ(i), such f(i) is determined to be an outlier. Then, the frequency is updated to fav(i). This filter is non-linear. The updated frequency fnew(i) through the filter which rejects the outliers is defined as Finally, the ultimate frequency ffinal is defined as ffinal is calculated from smoothing fnew (i).

EXPERIMENT The wrist-type PPG sensor weared in left wrist. LED to measure PPG is built on the back of the wrist-type sensor, and the accelerometer is built-in. Heart rate is defined as the number of times the heart beats in one minute. In practice, instantaneous heart rate calculated from the difference of time of beats is evaluated. For comparison, test subjects also wore holter ECG sensor which is medical equipment.This holter ECG is able to detect R wave even during movement.

Result The blue line shows the correct value calculated from holter ECG. The method using acceleration (red line) in this paper has higher accuracy than the comparison value affected by artifacts (green line). The result of all subjects is that correlation coefficient r = 0.98, and the standard deviation of error SD = 8.7 bpm.

CONCLUSION This paper reports estimating heart rate using wrist- type PPG sensor while the test subject is actually running. The proposed method has a higher degree of usability compared to existing methods using ECG. As of the experiment, the results were closer to holter ECG in high accuracy (r = 0.98, SD = 8.7 bpm).