HOW NAD - RDD duct diffuser

Slides:



Advertisements
Similar presentations
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Advertisements

AIR CONDITIONING ACCESSORIES
BASICS OF HVAC Ivy Tech Community College. Definitions – Page 862 HVAC systems are made up of the mechanical equipment such as the furnace, air conditioner,
Chilled Beam Presentation
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Design a Room Project. Design a Room You will need – 1 cm Graph Paper to draw your map – Graph paper to complete your calculations. Keep it neat and organized!
Airflow Properties & Measurement
1 Meeting ASHRAE Fundamentals, Standard 55 & 62.1 with Chilled Beams Displacement Ventilation.
The House as a System 1. Air Temperature and Water Vapor.
Trevor Thompson Senior Project II Vermont Technical College Spring 2011.
Lindab Pascal - Simplified VAV solution with full potential...
“Design of Water Supply and Sewer Systems” IV. Water Tank (Service Reservoir). Dimensioning and Constructing (Drawing 4) Main Procedures 1. Determination.
The International Authority on Air System Components Fan Performance Mark Stevens Director of Laboratory Services AMCA International.
Ventilation of the LH2 Target GHS In MPF-35: The target gas handling system (GHS), target cryostat, and part of the vent stack are covered by a tent that.
Plenum Runs Plenum Runs. Plenum Run Usually located in the attic or basement. Run in any location accessible for attachment of supply tubing. More economical.
© Irrigation Association Effect of Irrigation. © Irrigation Association Calculate Hydraulic Requirements Chapter 4:
Heat Exchange Ventilation Heat Exchange Ventilation.
MECHANICAL ENGINEERING FOR SYSTEM BALANCE ASHRAE MEETING 2/15/2007 NORTHERN NEVADA CHAPTER 126 MATT BRENNAN, TBE.
Modu-lab Low Cost Tools for High Tech Learning Electro-Mechanical Services, Inc. 109 Hermosa Dr. SE Albuquerque, NM Ph: Fx:
A Damper for every Duct! Young Regulator Product Line Think Young!
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
ADS / PHX SERIES SYSTEMS DESIGN
Lindab | we simplify construction - Flexibility when it is needed... Premum & Premax With unique JetCone and Angled Nozzles Patent pending solution.
Testing Fan Filter Units
1 System Design. 2 Primary Detection Secondary Detection Standards Pipe Design.
Residential Floor Plans
Are you sitting… well? About comfort,. As a responsible of occupant comfort, we all have a duty to make a careful selection of appropriate diffusers and.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
Objectives Describe room distribution basics Select diffusers
Chapter 3: Solving Equations 3.7 Percent of Change.
Plenum Plenum design is based on Equal Static Pressure using Static Regain Most duct systems are designed to maintain Equal Friction or Equal Velocity.
What makes up a Unico System
Objectives Air Distribution Systems -Diffuser selection -Duct design.
Duct Design Basics Lesson 4 Manual D Primer. Available Static Pressure 4.4.
Lesson 1 Friction Chart Primer 1.3 Friction Chart.
Objectives Finish heat exchangers Air Distribution Systems
Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Learning, our way DUCT DESIGN (material to be checked with local legislation) Daikin Europe, Consulting sales section.
Under floor heating Designing underfloor heating (UFH) system must always comply with the system suppliers instructions.
HVAC DUCT CONSTRCTION EXAMPLES
Revoir titre.
Wega & Wega Power chilled beams
Maria’s Restaurant Chapter 3 Section 13
HOW SAL 35 - Linear diffuser
CHAPTER 11 -Hangers & Supports -Outside ducts
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Objectives Finish with Exchangers - Start Air Distribution Systems
MECH 8250 – Building Systems Winter 2015
Maria’s Restaurant Chapter 3 Section 12
Introduction – Who am I? Environmental Project Manager – Trident Technical College Mechanical Engineer Licensed Builder South Carolina Accredited Commercial.
Maria’s Restaurant Chapter 4 Section 14
Unico Installation Rules
ICE 101 APPLICATION GUIDE INTALLATION AND OPERATIONAL CONSIDERATIONS.
MDS Selection.
2 Days National Workshop on “National Building Code of India 2016 ”
Technician’s Guide and Workbook for Zoning Section 3: Single Zone Airflow Balancing and Thermostat Location.
Objectives Finish with Duct Design Diffuser Selection
Technician’s Guide and Workbook for Zoning Section 1: Introduction
TECHNICAL TRAINING 2007.
HOW NAD - RRA duct diffuser
Temperature and Comfort Complaints
Zoning Load Calculations
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Mandatory Design Requirements
Calcul réfléchi 2 Multiplier par 5.
To be able to calculate the surface area of cubes and cuboids
Objectives Duct Design AND Diffuser Selection.
Follow-ups from Classes 8 and 9
Maria’s Restaurant Chapter 3 Section 12
Presentation transcript:

HOW NAD - RDD duct diffuser

What you need to know before you start? HOW NAD - RDD duct diffuser What you need to know before you start? What type of application? What is the usage ? (heating/air conditionning/Ventilation) What is the installation height? Are there any obstacles? What is the total airflow rate?

RDD Perforated duct diffuser HOW NAD - RDD duct diffuser RDD Perforated duct diffuser Perforation adapted to the configuration of the room Ideal for open ceiling applications Maximum installation height 60ft (18 m ) Minimum installation height 13ft (4.0 m)

Adaptive perforations HOW NAD - RDD duct diffuser Adaptive perforations

HOW NAD - RDD duct diffuser Large scale results

Selection steps Determine location of ducts Determine the Ø Diameter HOW NAD - RDD duct diffuser Selection steps Determine location of ducts Determine the Ø Diameter Balance the air flow Provide construction drawings

Sample of calculation Zone 1 : 4160 m3/h (2450 cfm) HOW NAD - RDD duct diffuser Sample of calculation Zone 1 : 4160 m3/h (2450 cfm) Zone 2 : 1232 m3/h (725 cfm) Height of underside duct: 13ft (4 m)

Example of layout Determine placement of ducts Determine the Ø HOW NAD - RDD duct diffuser Example of layout Determine placement of ducts Determine the Ø Balance air flow

Recommendations for direct connection HOW NAD - RDD duct diffuser Recommendations for direct connection Determine placement of ducts Determine the Ø Balance air flow

Recommendation for the connection between NAD and spiral duct HOW NAD - RDD duct diffuser Recommendation for the connection between NAD and spiral duct Determine placement of ducts Determine the Ø Balance air flow The supply duct exceed the wall an exact length of 2’’1/4 (58 mm)

Optimal layout The RDD covers the entire zone 5m HOW NAD - RDD duct diffuser Optimal layout Determine placement of ducts Determine the Ø Balance air flow The RDD covers the entire zone 5m

Selection of diameter Determine placement of ducts Determine the Ø HOW NAD - RDD duct diffuser Selection of diameter Determine placement of ducts Determine the Ø Balance air flow  

Diameter selection Zone 1 : Composed of 2 sections Section n° 1 : HOW NAD - RDD duct diffuser Diameter selection Determine placement of ducts Determine the Ø Balance air flow Zone 1 : Composed of 2 sections Section n° 1 : - 4 x Ø 556 mm Zone 2 : Composed of 1 section - 4 x Ø 353 mm

RDD Rules Install 1 Reducer or Damper every 50 ft HOW NAD - RDD duct diffuser RDD Rules Determine placement of ducts Determine the Ø Balance air flow Install 1 Reducer or Damper every 50 ft or every 10 active sections Prévoir un réduit ou clé de balancement tous les 25’ max

NAD Spec Chart Tableau NAD_Specifications RDD Identification Brand HOW NAD - RDD duct diffuser NAD Spec Chart Tableau NAD_Specifications RDD Identification Brand Model Airflow Ceiling height Height below the duct Room Temp in winter Room R.H. % in winter Temp. in duct In summer Tempin duct in summer Notes RDD-A NAD Klima RDD 1, 2, 3,4,5,6,7 RDD-B RDD-C 1, 2, 3,4,5,6, 7 RDD-D 1, 2, 3,4,5, 6,7 Note : 1 – 3/8 threated rod will be supplied by contractor. 2 – The color of the diffuser must be selected from the RAL chart 3 – The diffusers perforations are made with a software to meet the performance needs 4- The aluminium suspension rails will be painted the RAL color chosen and supplied by the manufacturer. 5- The rod covers will be painted the RAL color chosen and supplied by the manufactuer. 6- The ducts will be acoustically insolated by the manufacturer. 7- Starter flange included Cliquer sur image pour agrandir

Codification of RDD on plans HOW NAD - RDD duct diffuser Codification of RDD on plans Air flow TAG DIFFUSER RDD-A 85 l/s per section Ø 400 1500 Ø of the duct Length of the duct A- Ø550 85 l/s par section Ø 500 1500 RDD-A 85 l/s par section Ø 400 1500

Codification HOW NAD - RDD duct diffuser Cliquer sur image pour agrandir

Specification Available online in word format www.nadklima.com HOW NAD - RDD duct diffuser Specification Available online in word format www.nadklima.com