BMC Medical Co., Ltd. Nov. 2011 Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.

Slides:



Advertisements
Similar presentations
Using the SASS 3010 Particle Extractor
Advertisements

SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Training Presentation
Welcome to your Phaser 4600 printer
Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
Responder FW-60 Operation of the FW-60 Unit. Components 2 Solar Panel Spare Filters Power Supply Spare UV and Quartz Sleeve 12 Volt Pig-tail Hoses Strainer.
ELITE XR THERMAL IMAGER
Ice. Pure and Simple ™ Welcome to the Ice-O-Matic ® on-line training modules.
CLINITEK Status® Plus UACR Operator Training Program
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
The pumps should be tightened about once a month. If a new pump is installed, the pump should be initially tightened and then re-torqued one week later.
Working together to elevate the well-being of Tairawhiti Mahia nga mahi I roto I te kotahitanga kia piki ake te orange o te Tairawhiti SLEEP SERVICE Gisborne.
How to Clean the NEC VT676/67/575/470 Projector Filter
PN: TM rev:3 Preventive Maintenance Course.
Tracheostomy Cleaning Guidelines (All Information taken from individual manufacturer’s guidelines) Arcadia Cleaning Soak the tube for 60 minutes in warm.
1 USDOC41 Rev 0 1/04 Training and Education Program ©2004 HemoCue, Inc. HemoCue ® Training and Education Program The HemoCue Hb System.
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
FACSAria The basic parts
This is OK! The Clicker is in “Power Save” Also called “Sleep Mode”
Abaxis Piccolo xpress The piccolo xpress™ chemistry system is compact and easy to transport. The system consists of a portable analyzer and single-use.
Level 1 Rapid Infuser.
SUPER PASS II Personal Alert Safety System Charles Montgomery Fire Chief Course Developed by Lt. Ricky Phillips Sam Johnson Assistant Chief.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Slide 1UCSB CMS Weekly Status MeetingCMS 4-Hybrid Test System Sam Burke EE UCSB 4-Hybrid Thermal Test System Status 28 July 2003 Sam Burke UCSB HEP Group.
AccuMax Multi-Point Injection Mechanics
SCBA CLEANING Monthly and after use. Use mild detergent (dish soap) or Confidence Plus mixed at ½ ounce per gallon of water. Use a brush if necessary.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Accessories Planned Maintenance. Types l Humidifiers l Air Cleaners l Heat Recovery Ventilators l Condensate Pumps.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
Maintenance Course Preventive Maintenance Course.
CLINITEK Status® Plus UACR Operator Training Program
FROST I Site Initiation Visit version 1.4. IVTM System.
Balancer Operation Intelift Operation Installation Troubleshooting Preventive Maintenance Preventive Maintenance OVERVIEW.
TrueSTEAM™ Humidification Systems Module 7: Maintenance and Service.
Topic 7. What is atmospheric moisture? Atmospheric moisture refers to the amount of water in the air All 3 phases are included: solid, liquid and gas.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
Engineer Training Ink Insertion TJ8300 / TJ8500 Ink Insertion.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
Presented by: Rick Kuemin, MSA Training Director
Programming the CD101. Push and hold the SET button for 3 seconds.
Inspection, Cleaning, and Storage. Inspection Before each routine use and during cleaning Emergency use –monthly –after each use Escape –inspected prior.
TrueSTEAM™ Humidification Systems Module 6: User Interface.
2.5 Mixing Problems.  In these problems we will start with a substance that is dissolved in a liquid. Liquid will be entering and leaving a holding tank.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Aquarium Set-Up 20 gallon Penguin Biowheel. Safety First Electrocution is real; use drip loops Wet floors are slippery- always walk with caution Place.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
IOPtiMate™ OT-135P2 Technical Training – Part I System Description, Installation & Operation IOP (07)
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
MAINTENANCE INTERVAL SCHEDULE D6R TRACK TYPE TRACTOR 7AR EVERY 10 SERVICE HOURS OR DAILY.
KIRBY MORGAN HELMET MODELS
Coffee Dispenser Set Up and Operation. Set up and Operation Start Up following installation Assuming all installation requirements have been met and the.
Manual Instructions Installation Cleaning Instructions
Freestyle Precision Pro
Quick Start Guide for Flex Flow Pump
Rain stick Time: 10 minutes MateriaLs STEPS
Separating a Soluble and Insoluble Substance
Downloading a Purchased App from the Anderson One App Store
7.5 Taking care of crop conserving machine
14 Refrigerant Recovery, Recycling, and Recharging.
Respiratory Protection Training
Hosted Fax Self-Paced User Training
Saeco Espresso Intuita Descaling
Troubleshooting 11/14/2018 Water King Service Seminar.
Be Your Own First Customer Coffee (THERMAL)
How to set up the Flexmort CuddleCot™
Clinician Setup Manual
PowerPoint Slide Shuffler
Concorp, Inc. - Respiratory Protection Training. Revision – B
SAVI SCOUT® System Setup
Presentation transcript:

BMC Medical Co., Ltd. Nov Training Course

1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP

2 1. CATAOLGUE

3 RESmart AutoCPAP (APAP)

4 2. INSTALL & DISASSEMBLE

Install Install Water tank

Component Water tank, Humidifier, Device.

Disconnect the tubing from the water chamber. Press down on the water chamber and slide it out of the humidifier platform. Open the silica gel cover of water chamber and discard any remaining water. Fill a solution of warm water and a mild dishwashing detergent into the chamber, cover the silica gel cover, rock the chamber a few minutes, then outflow the solution. Rinse the chamber several times with clean water and allow to air dry. Fill the water chamber and close the silica gel cover. Inspect the water chamber for any leaks or damage. Replace the water chamber if any damage is present. Clearing Water tank

DISASSEMBLE Open the cover of the filter carefully. And then take it out.

DISASSEMBLE Press the button at the bottom of the main machine, then pull the heated humidifier.

SET UP 3. SET UP A. USER SET UP B. MAINTENANCE SET UP

SET UP Control Button

AutoCPAP AutoCPAP USER SET UP.ENTER USER MENU

AutoCPAP SET UP Verify/Change the RESmart USER settings. To start the setup menu, press and hold the Ramp button until the setup menu appear (about 5 seconds) when system standby. IMPORTANT! Press the Ramp Button to enter change status and press +/- User Buttons to change the setting. Press Ramp Button again to confirm the setting. Press +/- User Buttons to access the next setting.

AutoCPAP SET UP Setting the Humidifier When the optional InH2 Heated Humidifier is used, this setting can change the temperature and humidity of airflow between level 0 to 5. Default setting is 3.

AutoCPAP SET UP Setting the Altitude The altitude setting can be changed between level 0 to 2. Default setting is 0. 0 = less than 2,460 ft. (<750 m) 1 = 2,460 to 4,921 ft. (750 m to 1500 m) 2 = 4,924 to 8,202 ft. (1501 m to 2500 m) *over 8,202 ft. = The airflow pressure may not be accurate. Contact your home care provider to have your pressure setting adjusted.

AutoCPAP SET UP Setting Auto ON When the RESmart Auto is standby and wearing mask, your deep breath will start airflow automatically. Default setting is Enable.

AutoCPAP SET UP Setting Auto Off When the mask is removed, the RESmart Auto will stop airflow automatically. Default setting is Disable. Note: We advice you can set Auto Off is Disable. Most machine may appear this kind of problem, because apnea and mask off is not to be judged at pressure lower than 7 hpa.

AutoCPAP SET UP Setting the LCD Light This setting allows you to adjust the LCD light among Auto, On and Off. Default setting is Auto. Auto: LCD light will be turned on when any button pressing and turned off after few seconds. On: LCD light will be turned ON always. Off: LCD light will be turned OFF always.

AutoCPAP SET UP Setting the Alert This setting allows you to turn on/off the patient disconnect alert. When a large, continuous air leak (such as mask removal) has been detected in the circuit, this setting enables/disables the audible alert (a beeping sound). This setting is only effective when the Auto Off setting is disabled. Default setting is Disable.

AutoCPAP SET UP Setting the Reslex The Reslex setting displays the Reslex level set by your home care provider. This setting allows you to adjust the level of air pressure relief that you feel when you exhale during therapy. Your home care provider may have already set a Reslex level. If this is not comfortable for you, you can increase or decrease the setting. The setting of 1 provides a small amount of pressure relief. To increase the pressure relief, change the setting to 2 or 3. Default setting is 0 (disable).

AutoCPAP SET UP Reslex working:

AutoCPAP SET UP Delay Off Setting When the optional InH2 Heated Humidifier is on, the machine will continue working for about 15 minutes at a very low pressure (about 2hPa) after RESmart Auto was turned off. This function will blow off the left vapor inside and protect the machine. Default setting is Enable.

AutoCPAP SET UP Sensitive Setting The Sensitive Setting is only available on Auto CPAP mode. This setting can be set from 1(At level 1, the treatment pressure will increase slowly) to 5(More faster than level 1). Default setting is level 3.

AutoCPAP SET UP Date Setting The current date is displayed and can be modified if needed. Note: Check and confirm this Date Setting frequently to ensure the usage blog is correct.

AutoCPAP SET UP Use Days The number of nights the RESmart Auto was used for therapy for more than 4 hours will appear. This screen is only for reference. Your home care provider may periodically ask you for this information.

AutoCPAP SET UP iCode It is an information code. Default setting is Disable. If you set enable. You will see using information with 1,7,30,90,182,365 day when you serially press Heated Humidifier Button on standby. The information include P95 pressure, AHI, SNI and mean pressure. iCode need to be translated by RESmart iCode software.

AutoCPAP SET UP Exit the Settings The settings are complete. Press the +/- user button to access the SAVE setting and Ramp Button to save all changes and exit the settings menu.

AutoCPAP SET UP AutoCPAP MAINTENANCE SETUP ENTER SETUP MENU

AutoCPAP SET UP Entering the Menu: Power off the machine Press and hold the Pressure Start/Stop Button and Ramp Button while connecting the power cord into the AC inlet. After several seconds the Maintenance Menu will appear on display screen as below.

AutoCPAP SET UP IMPORTANT!Press the Ramp Button to enter change status and press +/- User Buttons to change the setting. Press Ramp Button again to confirm the setting. Press +/- User Buttons to access the next setting as below.

AutoCPAP SET UP Auto mode: Treat P Max APAP Ramp Init P Unit Use Time Mask test Save Titrate mode: Treat P Max APAP Ramp Init P Unit Use Time Mask test Save CPAP mode: Treat P Manual P Ramp Init P Unit Use Time Mask test Save

AutoCPAP SET UP Treat Pressure: On Auto mode, this pressure is minimum pressure. On Titrate mode, this pressure is set as the prescription pressure or less. On CPAP mode, this pressure is the prescription pressure after ramp time. Setting range is 4-20hPa. Adjustment step is 0.5hPa. Default setting is 8hPa.

AutoCPAP SET UP AutoCPAPs operation on Auto mode The pressusre will change from Treat P to Max APAP

AutoCPAP SET UP AutoCPAPs operation on Titrate mode The pressusre change from Init P to Max APAP

AutoCPAP SETUP Max APAP: This setting is the maximal pressure which AutoCPAP system can reach. Default setting is 16hPa. Note: this setting is not effective on CPAP mode.

AutoCPAP SET UP Manual Pressure: This setting is only available on CPAP mode. This setting allows user to adjust APAP pressure by himself. Setting range is 0-2cm H2O. Adjustment step is 0.5cm H2O. Default setting is 0. For example: If this setting is 1cm H2O and Treatment Pressure setting is 8cm H2O, user may change the treatment pressure between 7-9cm H2O by pressing +/- User Button.

AutoCPAP SET UP Ramp Timer:The ramp time is from starting pressure to prescription pressure. Setting range is 0- 60mins. Adjustment step is 5mins. Default setting is 15mins. The pressure will not change during the ramp time (initial pressure).

AutoCPAP SET UP Ramp Starting Pressure: The starting pressure after blower is turned on. Setting range is 4hPa to Treatment Pressure. Adjustment step is 0.5cm H2O. Default setting is 4cm H2O.

AutoCPAP SET UP Unit: The unit of the output pressure, selectable between hpa and cmH2O.

AutoCPAP SETUP Use Time: Total hours this RESmart has been used will appear. This number is only for reference.

AutoPAP SETUP Mask Test This function is used to calibrate the exhaust flow of mask which is not provided by BMC. Connect the RESmart device to mask with tube and seal the cushion, which is the patient interface of mask by hand. Press the Ramp button to start the self-test. RESmart device will start the blower and calibrate the exhaust flow of the mask. The self-test lasts for about 1 minute. The blower will stop after the self-test is finished. During the self-test, make sure that there is no leak between the hand and the cushion.

AutoCPAP SETUP Save and Exit:The settings are complete. Press the +/- user button to access the SAVE setting and press Ramp Button to save all changes and exit the Maintenance Menu. IMPORTANT!To make all changes active, press the +/- User Button to access the SAVE setting and Ramp Button to save all changes and exit the Maintenance Menu.

Hide function The device can be read using information(AHI,SNI, compliance, P95 and Mean P )of last night, when you press Ramp button then press + or – button at the device standby mode.(1.79 version later) 43