Team A.W.E.S.O.M.-O 4000 February 20, 2007.

Slides:



Advertisements
Similar presentations
Instruction-Level Parallelism (ILP)
Advertisements

MIPS Pipelined Datapath
Review: MIPS Pipeline Data and Control Paths
ENEE350 Ankur Srivastava University of Maryland, College Park Based on Slides from Mary Jane Irwin ( )
ENEE350 Ankur Srivastava University of Maryland, College Park Based on Slides from Mary Jane Irwin ( )
1 Stalling  The easiest solution is to stall the pipeline  We could delay the AND instruction by introducing a one-cycle delay into the pipeline, sometimes.
Lec 8: Pipelining Kavita Bala CS 3410, Fall 2008 Computer Science Cornell University.
Computer Organization Lecture Set – 06 Chapter 6 Huei-Yung Lin.
Lecture 28: Chapter 4 Today’s topic –Data Hazards –Forwarding 1.
Computer Architecture - A Pipelined Datapath A Pipelined Datapath  Resisters are used to save data between stages. 1/14.
Supplementary notes for pipelining LW ____,____ SUB ____,____,____ BEQ ____,____,____ ; assume that, condition for branch is not satisfied OR ____,____,____.
Ceng 450 Project. Pinout of Processor Interrupt is optional Processor in_port[7:0] out_port[7:0] clock rst interrupt.
55:035 Computer Architecture and Organization Lecture 10.
Pipeline Data Hazards: Detection and Circumvention Adapted from Computer Organization and Design, Patterson & Hennessy, © 2005, and from slides kindly.
Pipelined Datapath and Control
CPE432 Chapter 4B.1Dr. W. Abu-Sufah, UJ Chapter 4B: The Processor, Part B-2 Read Section 4.7 Adapted from Slides by Prof. Mary Jane Irwin, Penn State University.
1 Designing a Pipelined Processor In this Chapter, we will study 1. Pipelined datapath 2. Pipelined control 3. Data Hazards 4. Forwarding 5. Branch Hazards.
CMPE 421 Parallel Computer Architecture Part 2: Hardware Solution: Forwarding.
TEAM FRONT END ECEN 4243 Digital Computer Design.
2/15/02CSE Data Hazzards Data Hazards in the Pipelined Implementation.
CSE431 L07 Overcoming Data Hazards.1Irwin, PSU, 2005 CSE 431 Computer Architecture Fall 2005 Lecture 07: Overcoming Data Hazards Mary Jane Irwin (
CSIE30300 Computer Architecture Unit 05: Overcoming Data Hazards Hsin-Chou Chi [Adapted from material by and
CPE432 Chapter 4B.1Dr. W. Abu-Sufah, UJ Chapter 4B: The Processor, Part B-1 Read Sections 4.7 Adapted from Slides by Prof. Mary Jane Irwin, Penn State.
Pipelining: Implementation CPSC 252 Computer Organization Ellen Walker, Hiram College.
CSE 340 Computer Architecture Spring 2016 Overcoming Data Hazards.
Interstage Buffers 1 Computer Organization II © McQuain Pipeline Timing Issues Consider executing: add $t2, $t1, $t0 sub $t3, $t1, $t0 or.
Pipeline Timing Issues
Computer Organization
Stalling delays the entire pipeline
Note how everything goes left to right, except …
ECS 154B Computer Architecture II Spring 2009
ECS 154B Computer Architecture II Spring 2009
ECE232: Hardware Organization and Design
Forwarding Now, we’ll introduce some problems that data hazards can cause for our pipelined processor, and show how to handle them with forwarding.
Chapter 4 The Processor Part 3
Review: MIPS Pipeline Data and Control Paths
Morgan Kaufmann Publishers The Processor
Csci 136 Computer Architecture II – Data Hazard, Forwarding, Stall
Morgan Kaufmann Publishers The Processor
Team A.W.E.S.O.M.-O 4000 February 27, 2007.
Pipelining review.
Single-cycle datapath, slightly rearranged
Pipelining Chapter 6.
Current Design.
Computer Organization CS224
Pipelining in more detail
Team Brian Leslie Tuesday, January 23, 2007.
Team A.W.E.S.O.M.- O 4000 February 13, 2007.
Data Hazards Data Hazard
Pipelined Control (Simplified)
Pipeline control unit (highly abstracted)
The Processor Lecture 3.6: Control Hazards
The Processor Lecture 3.4: Pipelining Datapath and Control
Control unit extension for data hazards
T.H.A.D.D. GROUP TOM DUAN HELEN YU ANDY LEE DANNY HUANG DAWEY HUANG
The Processor Lecture 3.5: Data Hazards
Instruction Execution Cycle
Pipeline control unit (highly abstracted)
Pipeline Hazards
pipelining: data hazards Prof. Eric Rotenberg
Pipeline Control unit (highly abstracted)
Pipelining (II).
Control unit extension for data hazards
Introduction to Computer Organization and Architecture
Control unit extension for data hazards
MIPS Pipelined Datapath
©2003 Craig Zilles (derived from slides by Howard Huang)
Pipelined datapath and control
Need to stall for one cycle.
ELEC / Computer Architecture and Design Spring 2015 Pipeline Control and Performance (Chapter 6) Vishwani D. Agrawal James J. Danaher.
Presentation transcript:

Team A.W.E.S.O.M.-O 4000 February 20, 2007

Progress Last Week Register file adjusted Working on datapath Pipeline registers are done Found an error in couple of our MUXs “My bad” – Brian

Registers Register File Pipeline Registers Updated inputs to work with pipeline processor Pipeline Registers Separate for data and control signals Data completed Control in progress

Datapath All components wired up Needs: Control signals Hazard detection Forwarding Unit

Datapath screenshots!

Close-Up: IF/ID, ID/EX, EX/MEM

ALU Currently fixing a couple errors w/ comparison operations “My bad” - Brian

Plan for this week We’re a little behind… But seriously: We are gonna catch up this week  But seriously: Finish control signals Start hazard detection & forwarding