WAYNE DALTON OF SYRACUSE PRESENTS:

Slides:



Advertisements
Similar presentations
October Module 5: Cleaning Activities and Checking Your Work Overview Interior cleaning techniques. Exterior cleaning techniques. How to check.
Advertisements

NFPA-101, LIFE SAFETY CODE, 2003 EDITION Chapter 15 Existing Schools
Annual Fire Door Inspection
Electronic Locking and Exemption Request Form Training
Fire and Life Safety Systems Confidence Testing Fire and Life Safety Systems.
Safety Training Safety First. EXITS All exit doors shall be maintained in operable condition. Exit doors shall not be locked, chained, bolted, barred,
East Carolina University Compressed Gas Safety Training Program
FIRE DOOR INSPECTIONS NFPA 80 STANDARDS THIS STANDARD REGULATES THE INSTALLATION AND MAINTENANCE OF ASSEMBLIES AND DEVICES USED TO PROTECT OPENINGS IN.
Nationally Recognized Testing Laboratories
ELEVATING WORK PLATFORMS By Richard Hadcroft. PARTIES INVOLVED.
Environmental Health and Safety Oklahoma State University Hazard Communication Your “Right to Know”
Frontline Fire Officer Training: Firestopping and Path of Travel Why it should matter to you Developed by the International Firestop Council
1. The student will be able to describe: ◦ the history of ASME and the National Board ◦ the history of the National Board Inspection Code ◦ how the NBIC.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Emergency Lighting Code Review Presented by Iota Engineering LLC.
Overview Cal/OSHA Section 4848, Title 8 NFPA 51B FM GLOBAL FM Approval
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
Designing and Installing Exterior Vapor Distribution Systems INTRODUCTION Course Overview and Objectives.
Building Codes Violation of building codes and regulations can cause injury to building users and expose architects to legal liability and the possible.
Fire.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
October Module 1: Regulations - The RRP Rule Addresses activities that disturb lead-based paint in target housing and child-occupied facilities.
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
Lumbermen’s Underwriting Alliance
FPF190: Fire Protection Fundamentals FPF190 Fire Protection Fundamentals 1 Code Consultant.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Telecom Cabling Fire Stopping.
Employee Emergency Action Plans and Exit Routes Training Program.
Health Facilities Planning Seminar Plan Review Division Irvin J. Poke, AIA, Chief Todd Y. Cordill, NCARB, Assistant Chief Providing for Michigan’s Safety.
Business Owners and Managers and the Fire Code
October Module 2: Regulations U.S. Environmental Protection Agency (EPA): Established accredited training and certification programs for workers,
CONTROL OF HAZARDOUS ENERGY LOCKOUT/ TAGOUT PROGRAM.
Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
Building Codes and Interior Design
International Fire Door Inspector Association Presents New Annual Fire Door Inspections NFPA 80 – 2007, 2010, 2013 Standard for Fire Doors and Other Opening.
AC Transit Hydrogen Energy Station / Oakland Fire Department Project AC Transit Hydrogen Energy Station / Oakland Fire Department Project You want to do.
October Module 6: Cleaning Activities and Checking Your Work Overview What is effective cleanup? Interior cleaning techniques. Exterior cleaning.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
Engineering Analysis of NFPA 285 Tested Assemblies
Firestopping – Filling the Gaps Makes a Difference Poole Fire Protection Brian Griffin & Jack Poole, PE 2007 DOE Contractor Fire Protection Workshop Argonne.
San Marino Unified School District Contracts Presentation Presented by: Wesley Lee, Budget Analyst October 28, 2015.
Introducing the Code of Practise for evacuation and first aid fire-fighting equipment The COP when viewed in isolation is nothing more than a document.
Means of Egress Part 3 Chapter 4.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
CIV Fitness/S&C Steven Tikkanen – F129 1 Sutherland College Health & Recreation Semester Version 1.
Code Officials and the Code Process.  Concentrates on the code process as a whole.  Different type of code officials  Various steps that are taken.
Fundamentals of Code Compliance AIA Connecticut Presented by.
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Firefighter Emergency Escape Systems New York State Department of Labor Public Employee Safety and Health (PESH)
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
Building Construction
WHAT TO LOOK FOR WHILE SIGNING THE DEAL WITH A FIRE SAFETY AGENCY? BY: BHAVNA SINGH.
Public & Private Fire Prevention Organizations and Functions
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
CITY OF HARARE EMERGENCY SERVICES
Barrier Management Symposium
We got some new procedures to follow.
INTD 405 Modern Practices in Interior Design DOOR & WINDOW SCHEDULES
GTEC 2017 Annual UST Management & Compliance Assistance Seminar
Fire Door Inspections Qualified Training
East Carolina University Compressed Gas Safety Training Program
INTD 405 Modern Practices in Interior Design DOOR & WINDOW SCHEDULES
General Requirements of NFPA 101
CABINET X-RAY MACHINE OPERATOR RADIATION SAFETY TRAINING COURSE
Fire Alarm Tech Practice Test # 16 NICET
Emergency Preparedness Requirements
Building standards Mr. Da Silva.
We got some new procedures to follow.
State Electrical Division North Carolina Department of Insurance
Presentation transcript:

WAYNE DALTON OF SYRACUSE PRESENTS: FIRE DOOR INSPECTIONS NFPA 80 STANDARDS THIS STANDARD REGULATES THE INSTALLATION AND MAINTENANCE OF ASSEMBLIES AND DEVICES USED TO PROTECT OPENINGS IN WALLS, FLOORS, AND CEILINGS AGAINST THE SPREAD OF FIRE AND SMOKE WITHIN, INTO, OR OUT OF BUILDINGS.

1.1.1 REQUIREMENTS . 1.1.1.WITH THE EXCEPTION OF FABRIC FIRE SAFETY CURTAIN ASSEMBLIES, THIS STANDARD ADDRESSES ASSEMBLIES THAT HAVE BEEN SUBJECTED TO STANDARDIZED FIRE TESTS.

1.1.3 REQUIREMENTS 1.1.3 REQUIREMENTS FOR HORIZONTALLY SLIDING, VERTICALLY SLIDING AND SWINGING DOORS AS USED IN THIS STANDARD DO NOT APPLY TO HOIST WAY DOORS FOR ELEVATORS AND DUMBWAITERS.

1.1.4 REQUIREMENTS 1.1.4 THIS STANDARD DOES NOT COVER FIRE RESISTANCE GLAZING MATERIALS AND HORIZONTALLY SLIDING ACCORDION OR FOLDING ESSEMBLIES FABRICATED FOR USE AS WALLS AND TESTED AS WALL ASSEMBLIES IN ACCORDANCE WITH NFPA 251, STANDARD METHODS OF TESTS OF FIRE RESISTANCE OF BUILDING CONSTRUCITON AND MATERIALS.

WHY CHOOSE WAYNE DALTON of SYRACUSE FOR YOUR INSPECTIONS? Wayne Dalton of Syracuse will drop test and repair your rolling steel fire doors/shutters and provide the verification form required by the NFPA 80 Our technicians are factory trained and IDEA certified We use only manufacturer’s certified parts for repairs We perform the drop test and document the test We provide the original completed drop test certification and a copy is given to the end user and we keep a copy on file Your door is tagged certifying the test was performed We can provide replacement doors should the need arise

ANNUAL TESTING OF YOUR FIRE DOORS AND SHUTTERS IS THE MOST COST-EFFECTIVE WAY TO AVOID MALFUNCTIONING IN THE EVENT OF AN EMERGENCY AND TO MAINTAIN A SAFE ENVIRONMENT FOR YOU AND YOUR EMPLOYEES TESTING WILL PROTECT YOUR INVESTMENT TESTING WILL EXTEND THE LIFE OF YOUR FIRE DOORS & SHUTTERS WHEN YOU HAVE YOUR FIRE DOORS AND SHUTTERS TESTED ANNUALLY YOU WILL HAVE THE PIECE OF MIND THAT THEY WILL FUNCTION PROPERLY WHEN YOU NEED THEM TO IT’S A SMALL PRICE TO PAY CONSIDERING THE ALTERNATIVE WE OFFER AFFORDABLE SERVICE AGREEMENTS FOR ALL FIRE DOORS AND SHUTTERS.

NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODE MOST CODES ARE MODELED AFTER THESE TWO PUBLICATIONS NFPA 80 & NFPA 252 ADOPTED BY MANY STATES, COUNTRIES AND MUNICIPALITIES LARGER CITIES AND COUNTIES MAY WRITE THEIR OWN CODES CODES MAY DIFFER FROM CITY TO CITY, COUNTY TO COUNTY ETC. LOCAL CODES SHOULD ALWAYS BE RESEARCHED

ADDITIONAL FIRE DOOR REQUIREMENTS MAY BE IMPOSED BY: ARCHITECTS BUILDING INSURANCE UNDERWRITERS RISK MANAGEMENT COMPANIES RISK MANAGEMENT DEPARTMENTS THESE INDIVIDUALS MAY ENFORCE ADDITIONAL REQUIREMENTS ABOVE AND BEYOND STATE AND LOCAL CODES, KNOWLEDGE AND UNDERSTANDING OF THESE ADDITIONAL REQUIREMENTS IS CRITICAL

AUTHORITY HAVING JURISDICTION – AHJ CODE ADMINISTRATION, FINAL CODE INTERPRETATION AND FINAL PRODUCT APPROVED FALL UNDER THE AHJ NFPA 80 DEFINES THE AHJ AS THE ORGANIZATION, OFFICE OR INDIVIDUAL RESPONSIBLE FOR APPROVING EQUIPMENTS, AN INSTALLATION OR A PROCEDURE. BUILDING CODE OFFICIALS: FIRE MARSHALS AND STATE AND FEDERAL GOVERNMENT OFFICIALS MAY BE AN AHJ GENERAL CONTRACTORS, FIREFIGHTERS AND BUILDING OWNERS ARE NOT RECOGNIZED AS AHJ’s

NFPA 80 DEFINES A FIRE SHUTTER AS A LABELED DOOR ASSEMBLE USED FOR THE PROTECTION OF A WINDOW IN AN EXTERIOR WALL. FIRE SHUTTER CONSTRUCTION IS DEFINED AS A FIRE DOOR WITHOUT GLASS LIGHTS AND CAN BE A SWINGING DOOR. A HORIZONTAL OR VERTICAL SLIDING DOOR OR A ROLLING STEEL DOOR.

ANSI/DASMA 204 STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES THIS STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES IS INTENDED TO COVER COMMERCIAL AND INDUSTRIAL TYPE WAREHOUSES, FACTORIES AND OTHER FACILITIES WHERE A SERVICE COUNTER FIRE DOOR, FIRE SHUTTER OR FIRE DOOR IS REQUIRED TO CLOSE AN OPENING IN A FIREWALL DURING AN EMERGENCY. ROLLING FIRE DOORS INTENDED FOR FREQUENT USE SHOULD BE DESIGNED FOR HIGH CYCLE OPERATION. THIS STANDARD IS NOT INTENDED TO COVER DOORS USED FOR EGRESS PASSAGE, NOR OTHER TYPES OF DOORS SUCH AS RIGID, FOLDING OR MULTI-LEAF SECTIONAL TYPE DOORS, COILING DOORS WITHOUT INTERLOCKING SLATS (SHEET DOORS), PREFORMED SLAT CONSTRUCTION OR SPECIAL APPLICATIONS.

SILLS AND COUNTERTOPS FIRE DOORS MUST CLOSE COMPLETELY ACROSS THE FULL WIDTH OF THE OPENING NFPA 80 REQUIRES THE FLOOR STRUCTURE, COUNTERTOP OF SILL BE CONSTRUCTED ON NONCOMBUSTIBLE MATERIAL COUNTERTOPS AND SILLS HAVE REQUIRED PROJECTIONS FOR BOTH WIDTH AND THROUGH THE OPENING OF THE COUNTERTOP MUST BE SEPARATELY LABELED TYPICAL RATING ON COUNTERTOP IS 1.5 HOURS. TYPICAL COUNTERTOP MATERIAL IS LABELED PLASTIC LAMINATE AND LABELED STAINLESS STEEL IS AVAILABLE FROM COUNTER FIRE DOOR MANUFACTURERS DEPENDING ON THE LISTING AGENCY APPROVAL, IT MAY BE REQUIRED FOR ALL SURFACES OF LAMINATED COUNTERTOPS TO BE LAMINATED, INCLUDING THOSE WHICH ARE NOT VISIBLE. THE LISTING AGENCY LABEL MUST BE VISIBLE AT ALL TIMES AFTER INSTALLATION. NOT ALL LAMINATES ARE APPROVED FOR FIRE RATED LAMINATED COUNTERTOPS.

CRITICAL INFORMATION FOR THE END USER IT IS CRITICAL THAT THE GENERAL CONTRACTOR, END USER, BUILDING MAINTENANCE SUPERVISOR UNDERSTANDS ADDITIONAL EQUIPMENT OR TRADE WORK CANNOT IMPEDE A FIRE DOORS ABILITY TO CLOSE UPON ACTIVATION. NOTHING CAN BE ATTACHED TO THE DOOR, AND THAT OBJECT SHOULD NOT BE STORED OR INSTALLED IN A MANNER THAT MIGHT OBSTRUCT THE DOOR OR AFFECT THE RELEASE DEVICES. THE ENVIRONMENT PLAYS A FACTOR IN HOW OFTEN A FIRE DOOR DROP TEST IS PERFORMED. NFPA 80’S REQUIREMENT IS ANNUALLY, HOWEVER IF THE FACILTY IS A PAINT SHOP, HAS FOREIGN MATERIALS, OR DEBRIS THAT ALLOWS FOR SEDIMENT TO FALL ON THE CABLES NOT ALLOWING FOR PROPER OPERATION DURING A DROP TEST YOU MAY CONSIDER SEMI ANNUAL INSPECTIONS.

HAVE YOUR FIRE DOORS TESTED ANNUALLY BY WAYNE DALTON of SYRACUSE CONTACT TARA @ 315-453-7733 tara@waynedaltonofsyracuse.com