I-CASS – Door Access System

Slides:



Advertisements
Similar presentations
PV String Monitoring Solution
Advertisements

Alarm transmission over IP networks
California Access Controls Inc Exciting features that are extremely easy to use Exciting features that are extremely easy to use Access Control.
ACCESS CONTROL SOLUTIONS
RFID Access Control System March, 2003 Softrónica.
bright blue. So Smart, Its Simple! To the Presenter:
INTRUSION ALARM TECHNOLOGY
CL100D series DSP controlled Uninterruptible power supplies.
SCW9057 Key Features/Benefits
Welcome to the Radionet Monitoring Secure-Com Presentation.
ARC reporting ARC Cerny Verze
MP200 Presentation MICRO-BIT TECHNOLOGY, INC..
Introduction Senior Design Team SD0609 ECE Card Key Security System Nick Moszer Raylin Nevland Ryan Lindsay.
Nios Multi Processor Ethernet Embedded Platform Final Presentation
PC Technology Chapter 6 Teacher: Manju JEOPARDY.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
SK-ACP Installation Overview
3G Monitor. 3G Camera Contents 3G camera Function Features 3G Camera's Application Scenes 3G camera's business mode 3G Camera Technical parameters.
Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
What we do Larotecs Web2M is an off-the shelf, end-to-end, web-based solution designed to manage multiple widely distributed devices.
THE DEVICE, THE FEATURES & Centralized Management System (CMS)
CIMCO Integration Software Products
ID to 8 Loop Intelligent Fire Alarm Panel
Name : Designation : Date of Presentation : Location : Presentation Heading – font Arial Name : Mahesh G Designation : Director Date of Presentation :
Nokia 30 technical specification
BioSENSE I introduction
POC Security System High security system combining PIN-on-Card, information security, physical access, control and alarm – all in one system.
Total HVAC Control from anywhere Easy control that can save a fortune
WELCOME A Security Masterpiece. Control Panel Line-up Max Zones Basic Zones Max Zones Basic Zones n 1725EX14 6 (4 + 2) n 1728EX15 7 (5 + 2) n 1738EX16.
1 Bosch Solution 16i Intrusion Control System. 2 STAU/SAL | March 2010 | © Robert Bosch GmbH reserves all rights even in the event of industrial property.
System Capacity MAP 5000 Release 1.2 Feature Overview
Pyronix Ltd. Secure House Braithwell Way, Hellaby, Rotherham, S66 8QY, UK T F E
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
Enterprise Software Solution Lab Pvt Ltd
SAC844 Anviz Online Training Lesson 8
Fingerprint Time Attendance & Access Control System
BioScrypt (OVP) 4G Lite Series
PulseHR Time and Attendance software development and coding web development, web hosting IT project management and consulting Str. Ghioceilor.
Attendance Monitoring System using RFID Technology Presented by : Ayesh Minawi Sudqi Yaseen Laila Ghannam Supervised by : Dr. Mazen Rasekh.
e-Solutions for Access Control, CCTV, Attendance Monitoring, Personal Identification, Building Management and Fire Detection SECURITY & SAFETY IS ONE.
CONTACTLESS Advanced punch-card system SYCAPS – Proximity Time Recorder.
Linkage Connecting system components. Allows configuring automatic actions Triggering outputs based on specific inputs Used for removing human reliance.
CM-707 Standalone Fingerprint Access Control System CM -707 is biometrics fingerprint recognition standalone access control system.It can store up to 800,1500.
Design and Development of High Performance PC Based Logic Analyzer MSc Project by Rab Nawaz Advisor: Dr. Shahid Masud.
Copyright © 2013 FingerTec Worldwide Sdn.Bhd. All rights reserved.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
System Components Hardware overview for Apollo ACS.
System Configuration An in-depth guide. Overview Main module for configuring system – Hardware – Access Levels – Maps – IF/THEN Functions – Operators/Permissions.
ET3100 BioFlex TimeClock. What is fingerprint scanning?  It is a pattern acquisition and recognition established on a person’s.
Introduction To DSX WinDSX DSS (Dallas Security Systems)
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Truly Powerful. Flexibility, Scalability, Reliability User Friendly Software  Predefined parameters  Scaled down for easy admin  Personalised reporting.
10 February Doors Software Overview. 10 February This presentation is an overview of the basic fundamentals of the Doors software. –Host computer.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
UNOCODE 299 Copyright Silca S.p.A UNOCODE 299.
Page 1 LXMG , LXMG LXMG , LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Modules Training.
Copyright © 2008 FingerTec Worldwide Limited. All rights reserved
Technical Introduction April Internal usage only 1 General Features  Self contained batch solution for small, standalone applications.  All functionality.
Access Control Products
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Access Control Hardware IXP20TOUCH System Controllers iTRT Door Controller 125kHz Antenna Readers FINGKEY Access Plus I mpro provide a wide.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
U-PROX SMART HANDLE Fully incorporated Wireless Handle and Furniture Locking Set.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
Hearty Welcome!.
C1300 advanced circular chart recorder
COSEC ARC IP based Access Control Panel.
SCADA for Remote Industrial Plant
High Security and Access Systems
【Date: 】
Presentation transcript:

I-CASS – Door Access System THE LEADING INNOVATOR OF SECURITY SYSTEM

Table Of Content Introduction to I-CASS. Comparison with K-series. System Component. System configuration. System Technology. I-Cass Features. Technical Specification. Precaution & Maintenance.

System Introduction(1) Max.32 doors access control system. Categorized into 2/4/8/12/16/24/32 doors version. Combination of existing door access system, time attendance system, and alarm monitoring system. T-series : Multi-door interlocking features K-series : Auxiliary Output relay based on defined transaction. FEP : Supervised alarm input points.

System Introduction(2) Integrated with S-series, K-series, T-series, Commando, Centurion and FEP alarm monitoring system design concept. Bring in wireless messaging technology. Short message service among very doors. Huge user and transaction storage capacity. High speed processing and respond time. Interactive blue light graphic LCD display Emergency over ride key( Electronic Key). Long reading range for proximity technology. Ready for mifare and wiegand 26/32bits.

System Introduction(3) People choose I-CASS for its flexibility usage in security access control and other relevant application such as: Multi-door anti-pass back that handling max.32 doors operation. Multi-door interlocking features that only allow one door to grant access at a time. Guard Tour application that enabling patrol guard perform checking duty. Ethernet and GSM ready for internal and external communication. Alarm break in protection. Fire alarm emergency exist.

System Introduction(4) Dual card entry mode and access counter mode for restricted access area. CCTV and building automation integration. 125Khz and 13.56MHz proximity technology interfacing. I-CASS is designed to meet customer application including Door access control Guard tour patrol Time Attendance Alarm monitoring Car Parking control Building automation Fire alarm panel integration CCTV integration SmartCard based solution

How security handled in I-CASS? System wiring design Electronic key design Communication data protection Emergency event or alert Low power and main fail power detection Communication break down protection Watch dog for safe guard

Benefit of using I-CASS To have more card user capacity in the system. To have a high speed and fast processing time for every operation. To have a large door capacity controlled under one controller. To have a alarm monitoring features at every door. To have a guard tour features at every door. To have SMS messaging service among door reader. To have variety choice of operation mode at every door. To have interactive graphic display on every door reader. To have emergency over ride system To have Ethernet ready capability

Comparison with existing controller(1) Feature/Spec. K-series I-CASS Interlocking No 5 door per group (100 group) Anti-pass back Available among max. 8 doors Available among Max.32 doors Dual card access Available (100 match code) Access Counter Available on every door setting Emergency Key override Tabular key lock Electronic key with 4 digits password. Display unit Normal dot matrix LCD Graphic LCD with blue backlit

Comparison with existing controller(2) Features/Spec. K-series I-CASS Ethernet No On board Ready GSM SMS Ready Alarm monitoring Based on TTL input on every controller only 2 supervised sensor points on every door Fire alarm Fire alarm for emergency door release Guard Tour Available on every door ready as checking terminal. Auxiliary Output Available

Comparison with existing controller(3) Feature/Spec. K-series I-CASS Speed 8Hz 24MHz User storage 5,000 users 20,000 users Transaction storage 2,500 50,000 users Door connection Max. 8 doors Max. 32 doors Processor 8 bits MCU 16 bits MCU RAM 128K Byte 2M byte

Comparison with existing controller(4) Feature/Spec. K-series I-CASS Short Messaging Service No Available among door readers Door release time zone Available on every door setting Lock out mode Emergency duress alarm Available General purpose relay output Available on controller Software 32bits SmartGuard series software 32bits SmartGuard I-CASS software

Level of Changes Existing System I-CASS System 19200bps 1024KB 8 6Mhz 32 60% more 40% 16 3 9600bps 2Mhz 128KB Bus Frequency Onboard RAM UART Size Door Connection Over all Features Comm. Speed Comparison with Castle-S/K/T&Commando System

System Component(1) I-CASS controller SmartBox (Door Interface Unit) Door Reader Electronic Key Power Supply PC interface (PCI) SmartGuard I-CASS v5.6 Used as real time processing unit for all door event and alarm. As card user databases storage. As log transactions storage. Used for all the user setting. Responsible for all the communication bus polling.

System Component(2) SmartBox-Door Interface Unit Used to control the electronic door lock device, door contact and lock release button. Used as reader interface communication gateway to controller. Perform basic door controlling function during system controller breakdown.

System Component(3) I-CASS Reader Interface Act as reader interface for proximity reader. Mifare® serial number interfacing. Wiegand 26bits interfacing. Keypad and LCD interfacing. Perform card number conversion. Display informative message. PIN generator Alarm arming and disarming interface panel

System Component(4) Electronic Key Connected to reader interface board Used during emergency breakdown to over-ride the door lock. Security key is stored with a standard encryption technique. 10 digits key with suitable password to release door lock.

System Component(5) PC Interface Unit (PCI) Used as a gateway for controller uplink and PC communication port. Used as a signal converter for RS232 to RS485 communication. Act as a software security key for software version determination.

System Component(6) SmartGuard –ICASS v5.6 32bits PC software. Act as a interface software for data or user setting downloading machine. Act as log transaction uploading software for data reporting purpose. Time attendance report generation.

System Configuration(1) In Reader Out Reader PC Interface Door Interface (2) Door Interface (4) Push Button Door Interface (5) I-Cass Software RS 485 BUS 4 BUS 3 BUS 2 BUS 1 I-CASS Controller PC I RS 232 Maximum 8 doors (expandable) Door Interface (3) E-Key Lock System Magnetic Sensor 2 Wires Door Interface (1) RS 485 RS 232

I-Cass Features Proximity Technology ABS Casing LCD Screen SMS Press Alarm Guard Tour Polycarbonate Keypad Alarm Systems Time Attendance Networking E - Key

Features Highlighted (1) Enable Short Message Service (SMS) Inbound System Outbound System Storage Capacity: 100 users with 50 characters each user. Doors forced open or burglary Owner SMS Preset greetings or short messages Employees

Features Highlighted (2) Guard Tour Feature Time set : 20 mins Time set : 10 mins Main Back Off Door 1 Door 2 Door 3 1. Configuration Door 2 “Beep” 2. He/She did not proceed to Door 2 3. He/She did not proceed to Door 3 Door 3 “Beep”

Features Highlighted (3) Controller storage capacity : Standard 20,000 users. Expandable to 100,000 users Event Transaction Storage Capacity: Maximum 30,000 events Multi door Anti-pass back. Multi door Interlocking On board alarm input and output point. Dual Card Mode.

Features Highlighted (4) Access Counter. Time Zone Control Door Release Button 2 Holiday Groups @ 50 settings per group. Software Configurable to general purpose relay output. Enable to Interface with CIA88 additional alarm input or output point. Maximum 32 doors linkage per controller. Keypad arming on every door. Controller backup. Electronic Key (E-Key) for emergency door release. Support K series feature. On board Ethernet. Graphic LCD.

Visit our website: www.castle.com.my for more information. ~ The End ~ ~ Thank you ~ Visit our website: www.castle.com.my for more information.