THE HIGHLAND COUNCIL BUILDING STANDARDS SERVICE

Slides:



Advertisements
Similar presentations
BS 9999 – The LFB Experience Fire Engineering Group
Advertisements

Fire-fighting & Rescue in Buildings with Engineered Solutions Roy Wilsher Director Community Protection & Chief Fire Officer.
Loft Conversions - The building regulations Chris Wigley MD London Building Control Ltd
International Building Code
NEW PART B Design Impacts Peter Chilvers - May 2007.
OCTES Workshop HIE Cowen House 1 st November 2012 Building Standards and Energy Conservation.
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Engineering Services Planning Limited
Fired And Unfired Pressure Vessels
Summary of NFPA 101 Interior Finish Requirements
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
1 Making buildings better Building Tight Chris Knights.
Welcome to Energy efficiency for gas-fired and oil-fired domestic heating and hot water systems Session A: Course introduction.
United States Fire Administration Chief Officer Training Curriculum Operations Module 16: Dormitory Simulation Exercise.
Guidelines and Required Codes That Affect Building Design
Fire Precautionary Arrangements Presented by Mick Leadbetter Fire Safety Adviser.
1 Lincolnshire Fire & Rescue Training Centre FIXED INSTALLATIONS DRY AND WET RISERS COMPETENCE STATEMENT 373.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
Smoke shafts vs pressurisation
Part B – Fire Safety Technical Seminar by Sussex Building Control West Sussex Fire & Rescue Service.
ACCESSIBILITY: A CODE COMPLIANCE AND EXISTING CONDITIONS ASSESSMENT AND SURVEY OF THE LIMERICK TOWN HALL MAIN STREET LIMERICK, ME ttl-Architects LLC 28.
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
Pre-qualification Structural Learning – Brief Introduction to MOE, FRC & MOA 29 March 2003 Aims  Recall your memory : how to review your scheme according.
Chapter 19 Electrical Plans.
Building Australia’s Future Energy Efficiency Introductory Awareness Training AUSTRALIAN Greenhouse Office Supported by: Step by Step Application of BCA.
Colt International Ltd
How to create... A Fire Evacuation Plan.
Health and Safety Manager
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Copyright © International Fire Consultants Ltd Sprinklers – An essential tool in fire engineering design Jon Pagan MA(Cantab) CEng MIFireE Director of.
Regulatory Reform (Fire Safety) Order 2005 Fire Safety Fire Risk Assessment Case Study Ken Stevens Risk Services Manager ProAktive.
LEGISLATION OVERVIEW & PROCEDURES Douglas Walker Chairman Scottish Registration Board Structural Engineers Registration Ltd.
“People feel better in Colt conditions” | “People feel better in Colt conditions” | Colt International Ltd Smoke and.
HVACR116 – Trade Skills Mechanical Drawings.
Registration no: Fire Engineering Design Consultants – treating your fire safety concerns Designing residential fire safety & the challenging area.
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
Fire Safety By Alicia Civile and Alexandra Fernandez.
Prof. Kyriakos Papaioannou ARISTOTLE UNIVERSITY GREECE 7th Intern. Sprinkler Conference-Copenhagen 24-25/6/
CLIC CES Meeting 14 jan 2009 A resume table for fire safety in LHC, and a possible scheme for other machine – part 1 CERN –SC Fabio Corsanego.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Constructing Architect. Ventilation – domestic buildings  Each habitable room as well as the dwelling as a whole must have a fresh air supply of no less.
-Too little or too much ventilation -Insufficient ventilation results in excessive indoor humidity -Uncontrolled ventilation can cause exhaust leaks within.
Engineering Analysis of NFPA 285 Tested Assemblies
Neil Cooper Fire Safety Residential Implementing the Changes.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
“People feel better in Colt conditions” | feel better in Colt conditions” | Colt International Ltd Smoke control.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
FIRE SAFETY IN MULTI-RESIDENTIAL HOUSING (Assisted Living & Extra Care) Presented by Roger Standish & Andrew Crooks.
The Chief Fire Officers’ Association The professional voice of the UK fire and rescue service Fire Safety & Housing Paul Dryden Greater Manchester Fire.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Aaron Nicholson Beca. by Aaron Nicholson C/VM2 Design vs Non C/VM2 Performance Based Design.
CITY OF HARARE EMERGENCY SERVICES
BOMBA BRIEFING QUESTIONAIRE FOR 30 AUGUST 2017
Code of Practice for Fire Safety in New and Existing Community Dwelling Houses Eamon O’ Boyle.
FIRE SAFETY IN HOTEL (BIS )
FIRE PROTECTION & SECURITY in ELI Beamlines
AR-315 BUILDING CODES & BYE LAWS
Prepared by Frank Cooney B.Arch MRIA
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Decree of the Ministry of Interior 3rd August 2015 The “so called” Italian Fire Prevention Code - IFC: S6 – Fire Control and Suppression provisions.
Total Fitness Gym By Student Architect Jhonatan Rubio
When is a stay put policy acceptable
February 2019.
Firefighting equipment
Interactive Source: Fire Statistics Great Britain,
Smokes extraction principle
Conference 2015 Chris Barry, B.Sc. M.Sc. Pg. Dip. F.S.P. N.D.F.E.M.
Building standards Mr. Da Silva.
Presentation transcript:

THE HIGHLAND COUNCIL BUILDING STANDARDS SERVICE Dissemination Event 09 February 2011 The Highland Council Building Standards Service

Scottish Building Standards _____________________________________________________________________ Section 2: FIRE Domestic Handbook

Erratum’s Note: importance of amending the standards generally – two erratum’s – Feb 2011 and October 2010

General changes: Section 2 does not apply to any dwelling with an individual storey with an area in excess of 200m² (requires alternative approach i.e. “A simplified approach to alternative fire safety strategies” or fire safety engineering as outlined in 2.0.7) How to achieve? – early consultation essential

2.2 Separation 2.2.9 Openings and service penetrations: Any ventilation system with ductwork passing through a separating wall or floor should shut down automatically if fire is detected Standard states : “Any damper used in the design should be activated by smoke detection. For more detailed guidance, see BS 5588: Part 9: 1999.” However erratum clarifies…..

2.9 Escape 2.9.2 Escape within dwellings – options: First Stage means of escape Table introduced which summarises options based on topmost storey heights (or depths for basements) for escape within dwellings (includes houses, flats and maisonettes)

2.9.2 – Open plan (Domestic) Sprinkler Protection (BS 9251 2005) plus enhanced fire detection and alarm system ( BS 5839 pt6 2004 GradeLD1) Protected Enclosure option or→ Sprinkler Smoke detector 8

2.9.7 Escape within dwellings - open plan option with suppression and enhanced early warning system Kitchen should be remote from the exit door Fire suppression system and fire detection and alarm system should be installed throughout the dwelling and not just to the upper or topmost storeys Category LD1 system (BS 5839:Pt6: 2004) of AFD required for early warning

2.9.5 Escape within dwellings – protected enclosures Clarifies protected enclosures must lead directly to an exit door – shouldn’t require to leave enclosure to exit the dwelling Junction of walls with floors should be firestopped within the depth of the floor to protect the route of escape Clarifies that cupboard doors need to be fire resisting but don’t require self closing devices unless there is an ignition source e.g. boiler, hot water tank or distribution board

2.9.8 Escape within dwellings - ducted heating and ventilation systems For dwellings with basements or storeys in excess of 4.5m requirement for dampers or fire resistant ductwork to be fitted to ductwork passing through fire resistant constructions – e.g. protected enclosures Guidance identifies limitations on the passage of ductwork e.g. no transfer grilles between any room and protected enclosures, if system is re-circulatory smoke detectors to be installed within the ductwork to provide early warning and shut down extract air. Heat recovery systems – dampers or fire resistant ductwork where leaving the kitchen

2.9.9 Escape routes – general principles Second stage which introduces means of escape from the entrance doors of flats and maisonettes

2.9.10 Escape routes - options Options are in large part similar to those in previous standards but the table to this standard has introduced a further option of providing fire suppression which allows removal of protected lobbies in flats maisonettes having a topmost storey not exceeding 7.5m in height Travel distance (dash distance) from door of flat/maisonette to door of exit stair increased from 7.5m to 10m within the protected lobby

Protected lobbies: If protected lobbies are chosen as an option for flats they need either: Natural ventilation by: automatic ventilator in external wall (1.5m²) or smoke shaft or Mechanical ventilation by: Depressurisation or Pressurisation or Heating and ventilation systems

2.9.15 Escape routes – natural smoke ventilation Smoke shafts now introduced as an alternative to automatic opening ventilators. In effect a chimney within the protected lobby which naturally draws smoke from an opened fire door to a flat Guidance clarifies how they should be constructed and designed to operate on activation of the smoke detection system within the protected lobby What to specify? - full details of the smoke detection systems linked to the smoke shaft or automatic ventilators and a specification for the smoke shaft or ventilator construction and operation

2.9.20 Escape routes - openings Refers to shutters or dampers installed on a ducted system (heating or ventilation) being activated by localised smoke detection rather than heat activation to limit the spread of fire and smoke in escape routes from the flat or maisonette

2.9.22 Escape routes – external escape routes and escape stairs Guidance on external escape stairs as before but additional guidance identifies need to provide a 1.1m high fire protected (short duration) route past openings in an external wall where it’s not possible to freely disperse from the final exit to a place of safety How to show compliance? – elevation highlighting the minimum 1100mm height of the protected area and a specification for the short duration wall (oddly no requirement for insulation element of fire resistance)

2.11 Communication 2.11.0 Introduction Enhanced statistical information on the causes and locations of most domestic fires e.g. 62% of fire related deaths occur within the living room or kitchen

2.11.1 Fire detection and fire alarm systems Now a requirement for a minimum Grade D fire detection and alarm system in accordance with BS 5839:Pt6: 2004 for all dwellings (previously only where a storey in excess of 200m²) Smoke alarms now required in every: principal habitable room (normally living room, lounge etc) circulation space such as hallways and landings inner room and their access room Heat alarms needed for every kitchen

2.11.2 Choice of fire detector: Major change is the requirement for the designer to consider the most appropriate type of detector for each space to reduce the possibility of false alarms Guidance lists the different types of detectors: • optical smoke alarms; • ionisation smoke alarms; • multi sensor alarms; and • heat alarms

2.11.2 Choice of detector 2.11.3 – 2.11.6: Descriptions of each type of detector/alarm and their recommended locations e.g. : optical smoke alarms are generally recommended within principal habitable rooms and circulation spaces adjacent to kitchens ionisation alarms generally in circulations spaces adjacent to bathroom/shower-rooms heat alarms within kitchens

What information should be provided at assessment stage? location of heads on floor plans specification for the type of heads dependant on location - key specification for the type of system installed i.e. BS and grade What information needed at inspection/completion stage? : certification from the installer of the grade and type of system installed – design/installation/testing pro forma as previously for houses in excess of 200m²

Inner rooms an conversions: Need for detection in inner room and its access room – also applies to extensions or alterations which create inner rooms Conversions to comply - including conversions of attic or garage to accommodation

2.13 Fire and rescue service water supply Major change to re-introduce this standard back into the domestic handbook Every domestic building requires a water supply to assist fire-fighting either from a public water supply or an alternative water supply (or by alternative solution) Standards for public and alternative supplies as per Non-Domestic Handbook

2.13.2 & 2.13.3 Public and alternative water supplies 3 options: Compliant hydrant Alternative supply Alternative solution (suppression system)

Options: Hydrant should be within 100m of proposed dwelling – may be existing or if >100m - HIFRS to agree Alternative supply as before for Non-Domestic e.g. 45000 litre storage tank or pond, river, stream or loch with at least 45000 litres available all year round with suitable access and stance – HIFRS to agree Alternative solution – suppression (residential sprinkler) system – BS and HIFRS to agree

Consultation: Protocol developed with HIFRS to highlight need for designer to give early consideration of compliance at planning stage HIFRS not to be consulted directly. All proposals at time of building warrant application to be directed to Building Standards and a pro forma used to put forward case for consideration. BS to consult direct with HIFRS.

2.14 Fire service facilities 2.14.2 Number and type of facilities: No requirement for facilities within a house Facilities that may be necessary for flats and maisonettes include: • fire-fighting stairs (see clause 2.14.3); • fire-fighting lifts (see clause 2.14.4); • fire-fighting lobbies (see clause 2.14.5); • heat and smoke control e.g. natural or mechanical ventilation (see clause2.14.6); and • fire mains i.e. wet or dry risers (see clause 2.14.7).

2.14.3 Fire-fighting stairs at least one fire-fighting stair should be provided to all multi-storey buildings containing flats and maisonettes has to be at least 1m clear width to assist fire-fighters carrying equipment can also double as an escape stair

2.14.5 Fire-fighting lobbies Only required where height of storey in excess of 7.5m. Important to remember storey height is measured from fire and rescue service access level not from ground floor level for the purposes of the table to 2.14.1

2.14.6 Heat and smoke control Methods of smoke clearance to escape stairs has been extended to include smoke shafts as well as the existing vent at head or opening ventilators at each level A local control (simple handle or lock) to open the ventilator/s should be provided at the access level and topmost storey to assist fire service personnel in escape stairs and fire-fighting stairs

2.14.7 Fire mains Dry fire main (dry riser) only required where storey in excess of 7.5m from fire service access level Where an automatic fire suppression system is installed in the building no part of any flat or maisonette should be more than 60m from the dry fire main outlet within the stair or lobby. 45m if no suppression system

2.15 Automatic fire suppression systems Automatic life safety fire suppression systems are required in 2* categories of domestic building: dwellings which form part of a sheltered housing complex; and high rise domestic buildings. *But could be used as an alternative solution to providing features such as protected enclosures within flats and maisonettes or for water supplies for firefighting purposes for new houses

2.15 Automatic fire suppression systems Reference to “alternative or innovative suppression systems” but makes it clear that alternatives such as water-mist systems must be designed and tested for use in domestic buildings and proven fit for their intended purpose Assessment and Completion acceptance?: FIRAS or LPC accreditation for designers and installers of Residential Sprinkler systems– required to ensure competency and experience levels

2.A.1 Fire resistance duration Clarifies the need for test evidence and certification to be provided and checked to ensure the performance criteria is being met by the proposed design e.g. small differences in detail of a fire door assembly or installation may impact on the fire tests and rating - need for this evidence to be submitted as part of the application for fire resistant elements and constructions e.g.: Walls and floors Doors and glazed openings Dampers and collars Intumescent firestopping Cavity barriers Including fixing and installation methods