Presented by Jay Gandhi, PhD

Slides:



Advertisements
Similar presentations
Ic_sampl_prep_ _e.ppt 1 IC Metrohm inline sample preparation Techniques for analytical success Metrohm Ion Chromatography Bart Cleeren, Metrohm.
Advertisements

Ion Chromatography. Ion Exchange Separation is facilitated by formation of ionic bonds between charged samples and charged column packings.
Leaders in Environmental Testingwww.stl-inc.com Low-Level Perchlorate Analysis in Groundwater by Improved IC & LC/MS/MS March–April 2003 Presented by STL.
EVALUATION OF E85 FUELS Presented at the 6 th Annual Fuel Ethanol Laboratory Conference By Jerry King.
Gas Chromatography in the detection of Volatile Organic Compounds.
Ion Chromatography HCO 3 - /CO 3 2- Eluent Eluant M NaHCO M Na CO 23 ~2 ml/min flow Pump ,000 psi 1,000 nominal Check for air bubbles.
Ion Chromatography Figure 2. Ion chromatography. Chromatography is the process of separating different components from a solution or a gas. Chromatographic.
An Improved Ion Chromatographic Method for Low Level Perchlorate Analysis Peter E. Jackson, Ph.D. Environmental Market Manager Dionex Corporation 1228.
Determination of Oxalate and Other Anions in Beer Mike Marroquin and Katie Vautier.
Results Initial chromatographic conditions [Figure 2a caption] for the separation of the degradation products of aspirin were problematic due to the long.
Lecture 8. GC/MS.
1. PERCHLORATE Kevin Mayer - U.S. EPA, Region 9 What is Perchlorate - Chemistry & Uses Occurrence in the U.S. and Southwest Brief History of Environmental.
Recent Developments on Perchlorate Groundwater Pollution within the Los Angeles Region Information Item No. 15 for January 30, 2003 Public Meeting California.
Nitrosamine Detection in Meat By Beryl Ombaso, Chemistry 4101, Fall
New Nuclear Power and Climate Change: Issues and Opportunities Student Presentation Ashish K Sahu and Sarina J. Ergas University of Massachusetts - Amherst.
Contaminant Candidate List (CCL) Regulatory Determinations Water Quality Training Roundtable 2000 February 7, 2000.
Perchlorate April 14, 2004 An Integrated Approach to Ensure Reliable Perchlorate Analytical Results.
Perchlorate Analysis by Ion Chromatography The CA DHS Protocol H.S. Okamoto, D.K. Rishi and S.K. Perera.
Columbia Lake, Waterloo, Ontario, Canada
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
Chromatography vObjective  To understand the principles of chromatography and know the specific types of Chromatograph used in the analysis of environmental.
Field Methods of Monitoring Aquatic Systems Unit 9 – Ion-Chromatography Copyright © 2006 by DBS.
1 University of Massachusetts at Amherst Department of Chemistry Project 3: Silver Nitrate Detection of the Arsine Gas produced from the Gutzeit Reaction.
PERCHLORATE Kevin Mayer - U.S. EPA, Region 9 75 Hawthorne, San Fran. CA What is Perchlorate - Chemistry & Uses Toxicity Brief.
U.S. Department of the Interior U.S. Geological Survey Monitoring perchlorate in shallow ground water in the Central United States National Water-Quality.
1 Analytical Methods for Perchlorate: Current Technology and Possibilities for the Future David J. Munch Daniel P. Hautman Office of Ground Water and Drinking.
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
Eliminating Molecular Interferences in ICP-MS for the Simplest Method Development Dr. Torsten Lindemann.
Ch. 5 - Solutions. A. Concentration The amount of solute in a solution. Describing Concentration % by mass - medicated creams % by volume - rubbing alcohol.
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
1/16/2016The GC-in-a-PC 1 Pneumatic Focusing Gas Chromatography PFGC Robert O’Brien, Portland State Univ. & VOC Technologies The GC-in-a-PC Development.
Using GIS to Map Chromium Occurrence in Drinking Water Nate Rogers CEE 6440.
Providing comprehensive scientific resources to environmental clients worldwide. Dissolved Gas Analysis: A Review and Comparison.
Presented by Deepthi Ravipati. Barbiturates are derivatives of barbituric acid. They act as central nervous depressants. These drugs are frequently used.
Capillary Ion Chromatography, Sample Analysis on Demand Salt Lake City, UT May 2012.
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
Indranil Sen, Wei Zou, Ryszard Gajek, Jianwen She*
Multi-Analyte LC-MS/MS Methods – Best Practice.
Researching Global Water Issues: Introduction to Ion Chromatography Research-Based, Interdisciplinary STEM Education (RISE)
Lomonosov Moscow State University Chemistry Department
DIRECT DETERMINATION OF PERCHLORATE IN DRINKING WATER BY ION CHROMATOGRAPHY Mehmet Fatih CENGIZ, Ayşe Kevser BİLGİN Akdeniz University, Faculty of Engineering,
Detected anions by other researchers
Analytical Chemistry II ChEm 321
Safe Drinking Water Act , CCL and Perchlorate
Pesticides in Groundwater
LC-MS/MS Analysis of Tetracycline antibiotics in Honey using Advance UHPLC-EVOQ™ SIMA LAB PVT LTD.
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
Agility WCX SPE Cartridges
Determination of carbamate residues in high-fat cheeses by ultra-high performance liquid chromatography–tandem mass spectrometry using zirconia-based QuEChERS.
The Use of Advanced Instrumental Techniques to Address Emerging and Unique Circumstance Contaminants Charles Neslund, Scientific Officer, Eurofins Lancaster.
Added Monrovia and South Bend to the slide.
The Analysis of Soils and Waters in Accordance with U. S
524.3 Purge Flow Study Anne Jurek – Sr. Applications Chemist
EPA Region 10 Alternate Test Procedures and Method Update Rule
High Resolution Quantitation of Microcystins with SCIEX X500R QTOF System KC Hyland.
Determination of Adsorbable Organic Halogen in Wastewater
Overcoming Challenges in Elemental Speciation Techniques
Supplementary Material
EPA method 521 by direct-inject LC-MS/MS
Presentation Title 11/28/2018 Confidentiality label
4 From Chemistry to Energy to Life Part A
A Field Analysis Technique for the Determination of PFAS Compounds
Chapter 9 Chemical Names and Formulas
Philippe Dekleva and Scott Noblitt MicroChemica, LLC Fort Collins, CO
Historical Review of Data Qualifiers and QC Formulation
M.S COLLEGE OF ARTS, SCIENCE, COMMERCE AND B.M.S
Transferring LC-UV to LC-MS.
Fast Analysis of Haloacetic Acids, Bromate and Dalapon Using Ion Chromatography Coupled with Mass Spectrometry Richard Jack, Charanjit Saini, Chris Pohl,
Damiana Gentili Qualified Person/QU Director 09/05/2019
Presentation transcript:

Presented by Jay Gandhi, PhD Trace Level Determination of Perchlorate in Various Water Matrices by Tandem Suppressed Conductivity and Mass Spectroscopy Environmental Monitoring Conference, Washington DC USA August 7th – 11th, 2017 Presented by Jay Gandhi, PhD

Today we will talk about….. Perchlorate Background and History Ion Chromatography methods Ion Chromatography with Hyphenated Methods Summary All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Perchlorate Background Used as rocket propellant Used in electroplating industry Used in fireworks There are also evidence of “naturally occurring Perchlorate – Chilean fertilizer” Why Analyze? It is persistent in environment It is believed to inhibit Iodine uptake in thyroid gland causing hypo thyroidism All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Perchlorate Background This map is downloaded from USEPA web-site. It represents Perchlorate users, manufacturers in the Unites States Map provided as public information on USEPA website - 2005 All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Possible Perchlorate Pathway Fertilizers containing Perchlorate Perchlorate Containing Irrigational Water Edible Plants (Fruits, Vegetables, Leaves) Consumed by Humans Consumed by Animals Meat and Dairy Products Leading threat for Thyroid disease?? All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Regulatory Timelines Under SDWA, USEPA determines which chemical contaminant to regulate (CCL – Contaminant Candidate List) Perchlorate was part of CCL1 – 1998 CCL2 – 2005 CCL3 – 2009 UCMR 1 – 2005 USEPA decision to regulate – Feb 2011 In 2006 – State of Massachusetts regulates at 2ppb In 2007 – State of California promulgated at 6ppb 12 Other states has adopted non-enforceable levels Reference document: https://www.regulations.gov/document?D=EPA-HQ-OW-2009-0297-0685 https://www.epa.gov/dwstandardsregulations/perchlorate-drinking-water All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Perchlorate USEPA Methods USEPA 314.2 USEPA 314.0 enhanced USEPA 332.0 / SW846 6860 USEPA 331.0 / SW846 6850 USEPA 314.1 All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Perchlorate USEPA Methods USEPA 314.2 USEPA 314.0 enhanced USEPA 332.0 / SW846 6860 USEPA 331.0 / SW846 6850 USEPA 314.1 All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

by Suppressed Conductivity US EPA method 314.0 enhanced Perchlorate by Suppressed Conductivity All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

USEPA method 314.0 (enhanced) AW US6-0071 AW US6-0241 Using a Functionalized Monolithic Column or Anion Exchanger Column All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

USEPA 314.0 - Perchlorate Standard in Matrix Eluent flow 0.7 mL/min Eluent 10.5mM Na2CO3 + 25% Acetonitrile Column Metrosep ASupp7-250 Column temperature 45°C Sample volume 1000 µL Detector Suppressed Conductivity Chloride Sulfate Component Name Retention Time, mins Concentration, mg/L Chloride 7.5 1000 Sulfate 11.5 Perchlorate 26.8 0.005 Perchlorate All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

USEPA 314.0 MCT Study Eluent flow 0.7 mL/min Eluent 10.5mM Na2CO3 + 25% Acetonitrile Column Metrosep ASupp7-250 Column temperature 45°C Sample volume 1000 µL Detector Suppressed Conductivity Component Name Retention Time, mins Concentration, mg/L Chloride 9.28 50 - 1000 Sulfate 19.7 Perchlorate 24.8 0.002 All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

MCT Study Data (USEPA method 314.0, section 9) All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

No Interference – PCBSA Perchlorate All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

USEPA Method 332.0 + OR All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

IC-MS Electro Spray Ionization All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Perchlorate mass (Cl35) = Perchlorate mass (Cl37) = Chlorine (Cl) = 35 - + 4 x Oxygen (O) = 4 x 16 = 64 Perchlorate mass (Cl35) = 35 + 64 = 99 75% Perchlorate mass (Cl37) = 37 + 64 = 101 25% All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Perchlorate Mass / interference Sulfur (S) = 32 + 4 x Oxygen (O) = 4 x 16 = 64 HSO4-1 (S32) = 1+32 + 64 = 97 HSO4-1 (S34) = 1+32 + 64 = 99 4% 4% of 1000 parts per million = 40 parts per million OR 40,000 parts per billion All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Perchlorate by ICMS / ICMSMS USEPA method 332.0 / SW846 6860 Perchlorate by ICMS / ICMSMS In Collaboration with USEPA (ODW-OGW / OSW) All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Metrohm Advanced IC – Agilent QQQ MSD All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

USEPA method 332 / SW846 6860 USEPA Method 314.0 USEPA Method 332.0 All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Chromatography All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

USEPA 332.0 – Perchlorate Calibration Overlay - ICMSMS Eluent flow 0.7 mL/min Eluent 10.5mM Na2CO3 + 25% Acetonitrile Column Metrosep ASupp7-250 Column temperature 45°C Sample volume 100 µL Detector Agilent QQQ Perchlorate All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Perchlorate Calibration AW IC US6-0240 AW IC US6-0244 m/z 101 Range for Calibration Standards 0.1ppb to 50ppb (ClO41-) All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

USEPA 332.0 – Perchlorate MRM and transitions All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

USEPA 332.0 – Perchlorate Ion Ratios Average (150+ injections) Ion ratio for m/z 99/101 = 3.108 USEPA method acceptable value = 2.31 – 3.85 All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

What is Ion Suppression In LCMS / ICMS world, this is commonly known term Explanation of “ion suppression” All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Effects of Ion Suppression All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

1 ppb Perchlorate CCV – Recoveries over 150+ injections Average recovery = 99.9% All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

MSD Interface after 150 injections No Salt deposition All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Summary Metrohm Developed Simple, rugged and isocratic analysis for Perchlorate Environment friendly Carbonate chemistry for analytical column Chromatographically resolved challenging matrices and interferences like 3000 parts per million TDS (1000ppm each of Chloride, Carbonate and Sulfate) No interference from industrial surfactant like p-Chloro Benzene Sulfonic Acid (PCBSA) 100% Solvent compatible IC hardware allowed to hyphenate with Single Quad MSD Triple Quad MSD Use of appropriate loop and MSD connections Adopting from method 314.0 to 332.0 All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Acknowledgements Ms. Shen Yi-Yang – USEPA OSW Dr. Steve Wendelken – USEPA ODW/OGW Dr. David Munch – Retired ODW/OGW Dr. Melvin Ritter – USEPA Region 6 Mr. Johnson Mathew – USEPA Region 6 Metrohm USA Applications Team Mr. Jay Sheffer Agilent Technologies Dr. Tarun Anumol Mr. Craig Marvin All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC

Thank you for listening ???? All Material Copyright 2016 by Metrohm USA NEMC 2017, Washington DC