Oil-tight MV fuse CEF-OT with TPC bushings

Slides:



Advertisements
Similar presentations
Medium-Voltage Switchgear - Then and Now -
Advertisements

ABB djr 00/2 Components USA. ABB djr 00/2 Thermal Considerations when Condenser Bushings Are Applied in Bus Duct.
April 27, 2012 Presented by: Andy Justice SWEDE Southwest Electric Distribution Exchange “The Evolution of Distribution Switchgear”
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
OHB Outdoor sulphur Hexafluoride circuit-Breaker
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
FIPTMV Medium Voltage Technology
Head (Project & Service)
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
Dry type transformers Zaragoza Traction application
3AH5 Vacuum Circuit-Breaker For Standard Applications
How Electricity enters in our houses Electricity supplied to us at our home is 220 volt and A.C.. This main line power and the wires carrying it are called.
Single Phase IEC and EATS Distribution Transformers
Medium Voltage Fuses. 2 Why do we need Medium Voltage Fuses? Medium Voltage fuses are used the protection for voltage transformers and medium voltage.
VisiVolt™ Passive Voltage Indicator OEM Presentation
Chapter 2 Transformers.
Pole Mounted Switch Disconnector NPS
MNS Sprint - A Market Driven Solution
All rights reserved Gas-insulated Switchgear (GIS)
ABB PTMV Poland 2003 MV Fuses ABB PTMV Division Factory in Przasnysz.
Fuses in ABB - General Presentation
Capacitor Training Duck River Electric Membership Corp. Doug Simpson.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Medium Voltage Outdoor Apparatus Portfolio
SF6 load break fault make switches for overhead networks
Cooper Bussmann Overview. Overview 2 Electrical Electronics Transportation World leader in Electrical fuse technology Solid growth in emerging markets.
Long Bo FT and Flanges April 12, 2012 talk Hans Jostlein 12/19/2015Long Bo FT and Flanges1.
Submitted to: Submitted by:
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
HNC/D Engineering Science
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Intellectual Insulation Indicator «3i»
CHAPTER 4 SINGLE-PHASE TRANSFORMER
Sub Station.
High Voltage Engineering
Classification of Transformers
Sensor presentation.
EPOX PRODUCTS.
SUB-STATIONS.
SIGENTICS HV Series S-modyn
3AH5 Vacuum Circuit-Breaker For Standard Applications
Sectos NXB and NXBD.
Sensor presentation.
Pulse valve manufactured by Maniks
Dust Collector Valve for Dust Collection System - Maniks
Basics of electrical engineering
Name, department/event, date
Circuit Breakers & Reclosers
& Transient Voltage Recovery Capacitors
3AH5 Vacuum Circuit-Breaker For Standard Applications
SION Vacuum Circuit-Breaker For Standard Applications
Engineering Project Cable Management.
ELECTRICAL POWER-II Electrical engineering sixth semester
إشراف: د.م. نضال الريس إعداد المهندس: محمد أبو حوران
Technical sheet N°1 Using at frequency 60 Hz All cb’s
Product Training Module
Incompatibility between MV Switchgear conforming TO the international standards and their use in DNO’s substations M. Arens – Y Tits – Belgium – Session.
All rights reserved Gas-insulated Switchgear (GIS)
PRYSUNTM Photovoltaic Cables Industrial Specialties - Solar
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Its strengths, your benefits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Substation Equipment's
ALTERNATIVE CURRENT & VOLTAGE SENSORS
Isolation Link Operation
Presentation transcript:

Oil-tight MV fuse CEF-OT with TPC bushings ABB Medium Voltage Products, Fuses, Tomasz Komalski, 2011 Oil-tight MV fuse CEF-OT with TPC bushings © ABB Group November 18, 2018 | Slide 1

Oil-tight MV fuse CEF-OT Main features Special design for installation inside transformer under oil, Construction compatible with ABB TPC transformer, Various tags for easy assembly in different solutions inside TPC or as free mounted inside transformer tank, Design including: Welded current path, Heavy striker (130N), Oil and water proof, Double sealing system, Fuse-link dimensions acc. to IEC 60282-1 Type II, Fuse-link is dedicated to work under oil in high temperatures (80 ÷ 105 ºC) without ageing, Possibility of working with associated switch or signaling device under oil. © ABB Group November 18, 2018 | Slide 2

Oil-tight MV fuse CEF-OT Electrical features& operating conditions Fuse-link type Rated voltage Rated current Maximum tested breaking capacity Minimum breaking current Rates power losses in air (W) CEF-OT 12/24kV 20A 31,5kA at 12kV 16kV at 24kV 80A 70 31,5A 105 Ambient operating conditions CEF-OT fuse-links can be operated under the following conditions: Immersed in transformer oil, at temperatures from -40°C to +80°C, In outdoor and indoor installations, at temperatures from -40°C to +40°C, Inside a TPC bushing. © ABB Group November 18, 2018 | Slide 3

Oil-tight MV fuse CEF-OT Dimensions © ABB Group November 18, 2018 | Slide 4

Oil-tight MV fuse CEF-OT Striker pin characteristics © ABB Group November 18, 2018 | Slide 5

Oil-tight MV fuse CEF-OT TPC bushings data Application Indoor and outdoor distribution transformers type TPC Equipped with current-limiting fuse-link 5A-31.5A Standards IEC 60137 – Insulated bushings for alternating voltages above 1 000 V IEC 815 – Selection and dimensioning of high-voltage insulators (outdoor type) intended for use in polluted conditions – II class IEC 60282 – High voltage fuses HN-52-S-24 – EDF Standard for mechanical strength Ratings f – 50 Hz, Um – 24 kV, PD level according to IEC 60137 (1.5Um/3 - 10 pC, 1.05Um/3 - 5 pC) © ABB Group November 18, 2018 | Slide 6

Oil-tight MV fuse CEF-OT TPC bushings data © ABB Group November 18, 2018 | Slide 7

© ABB Group November 18, 2018 | Slide 8