Toshiba S-MMS vs LG MULTI V Plus II

Slides:



Advertisements
Similar presentations
Benefits of Air Source Heat Pumps Larry Butz GEA Consulting.
Advertisements

INVERTER VRF COMMERCIAL A/C
Kjell Lundén Nordic Branch Office SANYO CO 2 Technologies at Ahlsell Seminar in Norway SANYO Airconditioners Europe. 21 April, 2008.
SINGLE SPLIT INVERTER AIR-CONDITIONER
DX-Central Air Conditioning Systems Smart,Flexible & Efficient Alternate for Malls and Commercial Buildings.
Heat Recovery for Commercial Buildings
HVAC System Design PES Institute of Technology. Objective Goal: To develop an automotive air-conditioning system that is smaller and lighter than with.
Technical Training It’s Not Your Father’s Air Conditioner! Your Instructors: ◊ Don Fort ◊ Courtney Gardner.
Copyright ⓒ 2008 All rights reserved LG Electronics Inc. Daikin VRV III vs LG MULTI V Plus II.
WMV-SERIES MODULAR DC INVERTER VRF ALWAYS BETTER CAC SOLUTION FROM GREE.
Overall issues for adequate design for high-ambient temperature operation by: Samir Hamed Petra Engineering Ind. Co. Rtoc member.
Thermosyphon - Free Cooling
S.C. KOYO ROMANIA S.A. ALEXANDRIA TELEORMAN
REFRIGERATION, COMPRESSED AIR SYSTEMS & EFFICIENT USE OF ENERGY
The new Super Multi from TCUK
Wall / V 12 V 12 Introduction Arguments Technical details Installation.
Overview of Liquid Cooling Systems Peter Rumsey, Rumsey Engineers.
Perfect solution for large building
IntelliCon ™ Product Line Manufactured by Intellidyne, LLC Distributed by: IMC.
How a Heat Pump Works By: Adam Meeker. What is a Heat Pump? A heat pump is a device which transfers heat energy from one place to another.
Objectives Solve examples Learn about refrigerants, compressors, and expansion valves (Ch. 4) Compare residential and commercial systems Introduce heat.
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
ROAD TO CLIMATE FRIENDLY CHILLERS Hydrocarbons & Absorption Chillers Systems: Development & Potential Dr. Alaa Olama Sept. 2010, Cairo, Egypt.
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
BCWC Water-cooled water chillers with centrifugal compressor/s
Pressure-Enthalpy and the Variable Refrigerant Cycle
Page 1 MCQUAY DIGITAL SCROLL SYSTEM Unit & Piping Selection.
Objectives Cooling Cycles –Examples Cooling system components Refrigerants.
Water is the Natural Choice Hydronic Comfort Systems Increase and Maintain Building Efficiency For the Life of Your Building
Parul Institute of Technology
ALTERNATE / SUPPORT SOLAR ENERGY BY “ECONOMIA” PRESENTATION ON MUHAMMAD ASLAM AZAD MD OF AGECO (PVT) LTD. MEMBER OF ASHRAE (AMERICAN SOCIETY OF HEATING,
Manoa Elementary School Amanda Cronauer Faculty Advisor: Dr. William Bahnfleth 14 April 2010.
Refrigeration What's Refrigerated? What makes up a system?
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 5 August 2014.
DC Inverter Mini VRF Reference projects Reference Project Mini and Multi Improvements Product line -up.
Refrigerant system of Inverter R-410A. denki.co.th Model type Model : Stand Model : Duct Model : Cassette Model : Wall mount Model : Wall and.
2016 Chiller New Products Presentation.
Enhancing The Efficiency Of New And Existing Cooling Systems Dr Robert Lamb CEng FInstR Group Sales & Marketing Director Star Refrigeration Ltd.
ARÇELİK TİCARİ KLİMA EĞİTİM DÖKÜMANI APPENDIX.
Aleph Networks Co. Inefficient Operation Recognized by Commissioning and Case Example of Countermeasures Ritsumeikan Uji HighSchool.
I-RACH range I-RACH range I-RACH range I-RACH range High efficiency air/water heat pump with INVERTER scroll compressor Range Modularity Components Highlights.
HCB 3- Chap 17A: Compressors and Exp Devices 1 Chapter 17A: COMPRESSORS AND EXPANSION DEVICES Agami Reddy (July 2016) Compressor types Reciprocating compressors:
Cooling Solutions for Telecom Precision Cooling for Maximum Efficiency
CHIGO HVAC Product Introduction.
Changing the way the world cools…now in India!
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Conventional HP Schematic
New 10kW CAC & NCAC High wall unit.
CHIGO VRF System Commissioning.
Specializing in Water-Cooled & Portable-Split Air Conditioner
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Xiaomin Pang, Yanyan Chen, Xiaotao Wang, Wei Dai, Ercang Luo
Lecture # 7 Min soo Kim Mechanical & Aerospace Engineering
Thermal Energy Storage
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Product Overview SEIYA 06, Sep. 2018
Application of High Efficiency Chillers in Hong Kong Baptist Hospital
Heat recovery feature Competitive approach
Trane Care Energy RTHD Adaptive Frequency Drive retrofit.
Objectives Cooling Cycles Cooling system components Refrigerants
Peter Luttik VP Technology.
MDS Selection.
Announcement Rapid and Early Energy Modeling for the Engineers for a Sustainable World Shah Smith and Associates Scott Sevigny Wesley Stidham March 8th,
HOW TO SAVE MAXIMUM ENERGY IN YOUR COMPRESSORS INSTALLATION
TECHNICAL TRAINING 2007.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Lineup (ATW) <2018> <2019> : New series Series Ref. Split
Radhey S. Agarwal Member, OORG
Liebert DSE High efficiency thermal management
on RAC Servicing Sector - Leakage Control -
Presentation transcript:

Toshiba S-MMS vs LG MULTI V Plus II I’m going to explain the difference between Inverter system and Digital scroll system. The main subject is the compressor. LG Electronics Inc. LGEHQ CAC Team

1. Compressor comparison Inverter Scroll compressor is the best solution for a commercial building. Reciprocating Compressor Rotary Scroll Strong point Low cost Middle cost, Compressing part is simple Liquid handling capacity Low vibration & noise, high capacity Weak point High Vibration, noise Less liquid handling capacity Low reliability (spring loaded vane) High cost Normal Capacity Low capacity (~1HP) Middle capacity (1~5HP) High capacity (3~10HP) use Refrigerator, WRAC PAC, RAC etc. Multi, Commercial A/C

Total power consumption (kW/h) 2. Power consumption comparison ■ Design condition of HCL COMNET SYSTEMS & SERVICES LTD - Total capacity of system : 560Hp (48Hp * 11EA / 32Hp * 1EA) 48HP 32HP Total power consumption (kW/h) Power consumption (kW/h) Nos. of ODUs Sub total (kW/h) Nos. of ODUs S-MMS 49.67 11 546.37 28.65 1 575.02 MULTI V Plus II 42 462 28 490 ■ Operation condition of A/C units - 24hours / day, 30days / month, 12month / year - Electrical charge : 6Rs / kWh 1month 1year Basic power consumption (kW/h) Total power consumption (kWh) Electrical charge (Rs) S-MMS 575.02 414014.4 2,484,086 29,809,037 MULTI V Plus II 490 352800.0 2,116,800 25,401,600 Gap 85.02 61214.4 367,286 4,407,437

<Cooling Capacity> <Power consumption> 3. Performance comparison under the hot temp. Inverter Scroll compressor has high performance under the condition of hot temp. Outdoor unit 100% Cooling Capacity (kW) Power consumption (kW) Outdoor temp(35℃) Outdoor temp(40℃) S-MMS 135 125.60 49.67 52.55 MULTI V 130.37 42.00 45.38 135 52.55 130.37 49.67 125.60 45.38 42.00 <Cooling Capacity> <Power consumption>

Convenient for handling large capacity 4. Compressor comparison (Efficiency) Rotary compressor is weak for liquid compressing and has 92% cooling and heating efficiency compared to scroll compressor. Toshiba S-MMS MULTI V PLUS II Capacity (kW) 25 24.0 MULTI V PLUS II Type Rotary type Scroll type 20 19.4 16.3 15 ※Based on 1 inverter comp. Structure 13.1 Frequency (Hz) 60 90 120 ※Reference from each companies’ compressor catalogue MULTI V PLUS II Less Liquid handling Convenient for handling large capacity Feature Volumetric Efficiency 92% 100% (Base) Origin of Development Toshiba (Japan) LG (Korea) [Efficiency comparison for compressor type (reference from air-conditioning technology thesis)]

5. Design limit comparison LG MULTI V PLUS II is excellent for maximum pipe length S-MMS MULTI V PLUS II Maximum pipe length 150m 200m Maximum relative pipe length 175m 225m Total expansion pipe length 300m 1000m Height difference (Upper outdoor unit) 50m 100m Height difference (lower outdoor unit) 40m Maximum length after first branch 65m 90m ■ LG MULTI V PLUS II system has a plate type sub-cooling HEX Increased sub-cooling by plate-type heat exchanger Enable to be long piping length and level difference More powerful Cooling operation Plate type SC

Finally we hope all our software will be help you to convenient and successful in the LG CAC Business, Thank you.

Appendix. Design limit of Toshiba S-MMS

Appendix. Design limit of MULTI V PLUS II Outdoor units MULTI V Plus II 110m ON ON ON Indoor units <DA Research Lab in Korea> 103m

Appendix. Power consumption of Toshiba S-MMS

Appendix. Power consumption of Toshiba S-MMS ■ Power consumption of Toshiba S-MMS 48HP : 49.67kW/h ※ Source - Toshiba Engineering data book

Appendix. Power consumption of Toshiba S-MMS ■ Power consumption of Toshiba S-MMS 32HP : 28.65kW/h ※ Source - Toshiba Engineering data book

Appendix. Power consumption of MULTI V PLUS II ■ Power consumption of MULTI V PLUS II 48HP : 42kW/h

Appendix. Power consumption of MULTI V PLUS II ■ Power consumption of MULTI V PLUS II 32HP : 28kW/h

Appendix. Compressor capacity of Toshiba ■ No of compressors – Toshiba S-MMS 48HP : 8 Compressors (4.2kW*2)*4 ※ Source - Toshiba Engineering data book

Appendix. Compressor capacity of LG MULTI V PLUS II ■ No of compressors - MULTI V PLUS II 48HP : 6 Compressors (5.356kW+5.3kW)*3

Appendix. Delhi temperature

Appendix. Load performance of Toshiba S-MMS ※ Source - Toshiba Engineering data book

Appendix. Load performance of Toshiba S-MMS ※ Source – LG MULTI V PLUS II Engineering data book

Appendix. Certificate for Energy conservation product