INTRUSION ALARM TECHNOLOGY

Slides:



Advertisements
Similar presentations
25-Mar-17 Circuit Examples [Title of the course]
Advertisements

Addition Facts
CONSTRUCTION BLUEPRINT READING
Closed Area Construction
SCW9057 Key Features/Benefits
1 Signals, Circuits, and Computers John Athanasiou Part B Spring 2010.
HWg-Juno HW group is a manufacturer of IP-based sensors from Prague, Czech republic. HWg delivers remote monitoring & control solutions.
CMPE 150- Introduction to Computer Networks 1 CMPE 150 Fall 2005 Lecture 6 Introduction to Networks and the Internet.
John Ogilvie High School - CfE Physics
Electrical Installation-Module 3
Burglar & Fire Alarm Basics
XT30/XT50 Basic Training System Overview
Daniel Bichler Page 1 Security and Privacy in Pervasive Computing Environments PhD project –Infineon AIM SC D TD, Munich –Started on
Addition 1’s to 20.
Week 1.
How Electronic Security Solutions can Help the Government in Securing its Assets and Reduce Energy expenditure Presented By- Nimish Vishnoi Manager-Product.
1 INTRUSION ALARM TECHNOLOGY NOTIFICATION DEVICES.
Medical Gas Alarm Panels
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
DUE Security and Fire Alarm Systems LEARNING OUTCOME 7B Describe design overview and location considerations.
Communications Technology 2104 Jenn Sandifer. A security alarm is a system designed to detect intrusion – unauthorized entry – into a building or area.
1 INTRUSION ALARM TECHNOLOGY WIRELESS SYSTEMS. 2 INTRUSION ALARM TECHNOLOGY Wireless systems use radio frequencies (RF) to connect sensors to the control.
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
1 Introduction to Telephony and POTS lines Introduction to Telephony and POTS lines BASIC TELECOMMUNICATIONS.
1 The pulse rate in the U.S. is 10 PPS. The break/make ratio is 60/40 DTMF = Dual Tone Multi Frequency Pulse refers to rotary phones Each digit on a telephone.
Security Devices A modern security system, with its array of electronic components, is designed to sense, decide, and act. The security system senses events.
BUILDING SECURITY ALARM SYSTEM. BUILDING SECURITY ALARM SYSTEM Any electrical or mechanical device which is designed or used for the detection of an unauthorized.
PIR MOTION SENSOR Mohammed Muhid Ahmed S Checked By: Uzair Aakhoon.
INTRUSION ALARM TECHNOLOGY
1 INTRUSION ALARM TECHNOLOGY KEYPADS (CONTROL UNITS)
Country house Control Panel Glass break detector Hooter alarm Magnetic sensor Motion detector Security light.
PIR MOTION SENSOR Created by: Zaryab Altaf S
Welcome Presentation On Office security system. Group Members: Md. Emdadul Haque Md. Sahed Hasan Md. Samsul Arefin Khokan Das.
Fire Detection Presentation
Burglar & Fire Alarm Basics
Systems Approach Burglar Alarm Project PROBLEM SITUATION DESIGN
INTRUSION ALARM TECHNOLOGY
Chapter 2 What is an Alarm System? Alarms: The First Line of Defense
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
1 INTRUSION ALARM TECHNOLOGY POWER SUPPLIES. 2 INTRUSION ALARM TECHNOLOGY Security systems shall have a primary power source and a secondary power source.
For: Communication Technology 2201 By: Chris Murphy.
Simple Output Devices TASK 1.Collect a set of Output Device cards. 2.Match each symbol to the correct name, energy change and type (digital or analogue).
ALARM MONITORING SERVICE
The 3 parts of an electronic system are :
Lesson 4 Physical Security - Motion Sensor - Passive Ultrasonic Sensor - Photoelectric System - Ultrasonic - Ultrasonic Motion Sensor - Vibration Sensor.
Beath High School - Int 1 Physics1 Intermediate 1 Physics Electronics Glossary AND gate to device digital signals to inverter LDR to logic circuit logic.
INTRUSION ALARM TECHNOLOGY
What is a circuit? A set of connected electrical components that provide one or more complete paths for the movement of charges. A set of connected electrical.
1.Mouths are quiet. 2.Begin the quick review section of your notes. 3.Raise your hand if you need something.
DIVISIONSPECIFICATION INPUT POWER DC 24V / 1.25A ※ Power supply from the floor distributor is not available. MAX POWER CONSUMPTION Max 30W VOICE CONVERSATION.
6.2 ELECTRONICS. CAPACITOR An electrical device used to store electrical charge.
Criminal Justice Intro to Security, Instructor Name Date, Semester Chapter 4: PHYSICAL SECURITY: STRUCTURAL, ELECTRONIC, AND HUMAN PROTECTION SYSTEMS.
Unit 1: Protecting the Facility (Virtual Machines)
Prototyping Home Automation Concepts
Electronic Eye Controlled Security System
XBee Based Industrial And Home Security System
Presentation On Office security system
AQA GCSE 6 Systems approach to designing Design and Technology 8552
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
Circuit Notes.
ELECTRICAL CIRCUITS.
ELECTRICAL CIRCUITS S.MORRIS 2006
Designing Electric Circuits
Learning Outcome 4 Understand the types, applications and limitations of wiring systems and associated equipment This presentation looks at emergency management.
ELECTRICAL CIRCUITS S.MORRIS 2006
Circuit Notes.
FIRE ALARM DRILL 26 © Ted Smith 2017.
Presentation transcript:

INTRUSION ALARM TECHNOLOGY INTRO TO INTRUSION ALARM

INTRUSION ALARM TECHNOLOGY An intrusion detection system consists of several different system components wired together to provide protection of persons and property.

INTRUSION ALARM TECHNOLOGY Intrusion detection systems (IDS) are also called security alarms, security systems, alarm systems, perimeter detection systems, burglar alarm systems and similar terms. Burglar alarms are used in residential, commercial, industrial, and military properties for protection against theft or property damage, as well as personal protection against intruders.

INTRUSION ALARM TECHNOLOGY Car alarms likewise protect vehicles and their contents. Prisons also use security systems for control of inmates. Some alarm systems serve a single purpose of burglary protection; combination systems provide both fire and intrusion protection. Many burg. Panels at a minimum provide a zone for smoke detectors.

INTRUSION ALARM TECHNOLOGY Intrusion alarm systems may also be combined with closed-circuit television (CCTV) surveillance systems to automatically record the activities of intruders. Many CCTV systems have alarm interfaces that facilitate quick and easy interconnection to an intrusion alarm system.

INTRUSION ALARM TECHNOLOGY Burglar alarm systems may interface to access control systems for electrically locked doors that require a key fob or access card/code. Systems range from small, self-contained noisemakers, to complicated, multi-zone systems with computer monitoring and control. PERSONAL ALARM SYSTEM “NOISE MAKER”

INTRUSION ALARM TECHNOLOGY A basic burglar alarm is a simple circuit consisting of a loop, switch, battery and a buzzer. The switch symbol represents many different types of detection devices, switches can be normally open (N.O.) or normally closed (N.C.).

INTRUSION ALARM TECHNOLOGY The switch symbols pictured below represent any detection device such as; PIRs (passive infrared), reed switches, tamper switches, glass break sensors etc. These devices are classified as either a normally open (N.O.) or normally closed device (N.C.). NORMALLY OPEN SWITCH NORMALLY CLOSED SWITCH

INTRUSION ALARM TECHNOLOGY As with many low voltage systems the primary component or heart of the system is the central device that controls all other components. In this case the control panel (CP) is the heart of the intrusion detection system. The CP houses all of the electronics used to monitor the detection devices and route signals to notification devices.

INTRUSION ALARM TECHNOLOGY Alarm systems can be sub-divided into three parts: DETECTION CONTROL SIGNALING

INTRUSION ALARM TECHNOLOGY We can further break down an alarm system into all the separate components.

INTRUSION ALARM TECHNOLOGY Detection devices are used to detect a human or non-human (animals,) intruders. Notification/annunciation devices communicate information about an intrusion system to its user, the information can be audible, visual or both. Communication devices communicate an alarm condition to the user or a monitoring station.

INTRUSION ALARM TECHNOLOGY Control units are keypads that are either LCD (liquid crystal display) or LED (light emitting diode) and provide the means to program the alarm system. The Power supply is both wired and battery back up which is self contained in the control panel enclosure.

INTRUSION ALARM TECHNOLOGY The separate components will be wired to zones in the control panel and it is common for the wiring schematics for the panel to be listed on the inside door of the enclosure. SCHEMATICS INCLUDED

INTRUSION ALARM TECHNOLOGY You have already been introduced to several abbreviations that are frequently used in the burglar alarm industry, we will cover a few more. CP = ? IDS= ? N.O.= ? N.C.= ? CONTROL PANEL INTRUSION DETECTION SYSTEM NORMALLY OPEN NORMALLY CLOSED

INTRUSION ALARM TECHNOLOGY EOL= End of lines resistor, this is used to monitor the wired loop. PIR = Passive infrared detector, a commonly used device to cover large areas. C = Used in control panels to indicate a common lead shared by two zones. POTS = Plain old telephone service, dial tone used by the control panel

INTRUSION ALARM TECHNOLOGY RJ-31X = Is an alarm panel jack, POTS gets wired to this jack. HUA = Holdup alarm, used on keypads or panic buttons. DS = Door strike JB = Junction box

INTRUSION ALARM TECHNOLOGY When working with blueprints to install an intrusion alarm system all of the devices will be represented with a box or rectangle containing an abbreviation. Cables are home runs back to the control panel and are labeled as zones. A zone can have a few devices or dozens of devices wired in either series or parallel.

INTRUSION ALARM TECHNOLOGY Here is an example of zone wiring, notice that zone 1 is a N.O. device loop and zone 2 is a N.C. device loop. WHAT DOES THIS LINE REPRESENT?

INTRUSION ALARM TECHNOLOGY The value of the EOL can be found on the control panel door in the wiring schematic. There are separate wiring terminals for communication devices, notification devices and keypads, these devices are not connected to the zone wiring loops.