Welcome to.

Slides:



Advertisements
Similar presentations
Instructional Presentation
Advertisements

Sectional Assembly and Installation
Welcome to.
F&T Inc. OVERHEAD CRANE SAFETY.
Zebra® 105SL™ * Removing and Installing Printhead
1.Cable management cover ( cpu only ) 2.Wired barcode scanner holder (optional) 3.Mouse holder and tray 4. Removable rear technology panel 5. Power cord.
Welcome to.
Equipment for Assembly Fluke Multimeter 115 True RMS Glue Ring Jig Flathead screwdriver 60 Watt desk lamp HIOS Cl 4000 Electric screw driver Anti-static.
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Swivel Light User Instructions Rotate cam counter clock wise to open battery compartment Spare battery can be installed in secondary chamber tip Down(power.
The EZ-SAT.
Club Car IQ Technical Information
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Optical Manufacturing Solutions 1 Probe Assembly.
Installation. Indoor Unit Installation Typical Installation.
AUDIO VISUAL TRAINING University Center. BLACK BOX EQUIPMENT IN CLASS University Center LCD Projector/Built In Screen Laptop Connection (VGA Cord) Control.
One Source Smarter Packaging Solutions WELCOME TO THE SAMUEL STRAPPING SYSTEMS BALER TRAINING PROGRAM Baler Overview Making a.
Digital StarLab Set-Up, Operation, Maintenance, and Teacher Manual for the Digital StarLab are in the links below or on the training tab in the BlackBoard.
Trouble - Shooting ELR - Electric Latch Retraction.
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
Laptop mobile work station. Laptop mobile work station with drawers.
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
Tool removed during cycle Fault #2 Conditions for setting Tool cocked prox switch goes open during cycle AND force on load cell drops below limit in fault.
Portable/Desktop Projectors Small and light, ideal projectors for transports.
Disabled Platform Access There are two designated parking bays immediately outside the front of the main college building. Disabled access both into the.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Power-Fill Operation Demonstration Power-Fill Operation Demonstration (See Installation and Operation Manual for detailed instructions)
SPS Secondary Beam Experimental Areas Access System 7 September 2012.
Chapter 3 Basic Vehicle Control
GAMMA & ROAD TUBE BASICS TRAINING
(Smart Loop System) Installation Guide. Rev B Shipping Box Contains Everything that is included in the box being shipped to a customer should contain.
AccuMax Multi-Point Injection Mechanics
How to Make a Simple DC Motor
Service Bulletin 161 SUBJECT: Upgrade to current production level UNITS:D27105 DATE CODE RANGE: All units up to date code to be checked ISSUED.
+ USING THE POWER CHARGER AND BATTERY MINI-DV CAMCORDER Connect the charger to the power cord Attach the battery to the charger Plug it in and watch for.
AUDIO VISUAL TRAINING Center for Academic Success.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
Installation. Indoor Unit Installation Typical Installation.
Welcome to.
GCS 300 System Operation Application – Level 1.
Set Up for Live Streaming Video This presentation will walk you through the set up and delivery for streaming video of a live event over the internet.
How to use the PRS Clickers with PowerPoint Created by: Lindsay Proctor.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
AUDIO VISUAL TRAINING Wilkins Theatre-Black Box. BLACK BOX EQUIPMENT IN CLASS Black Box LCD Projector/Built In Screen Laptop Connection (VGA Cord) Control.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
Tool Removed During Cycle Fault #2 Conditions for Setting Tool cocked prox switch goes open during cycle AND force on load cell drops below 5 lbs. Active.
SERVICE TRAINING EXPERT ALPHASTAR 1132 © MAO-SE-TC 1132_SE_EX_Handout_EN_12_  Collision protection switch  Collision protection switch retrofit.
6/13/2016 Quick Reference Parts Guide Introduction This Quick Reference Parts Guide is an easy way to locate part numbers to common replacement parts.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
7/7/2016 This Quick Reference Parts Guide is an easy way to locate part numbers to common replacement parts. It does not include items such as wire or.
Select your System Freedom Micro DI.
Chapter 3 Basic Vehicle Control
Fujitsu Training Documentation Hardware Installation
DESCRIPTION AND GUIDE TO OPERATIONS
Tool removed during cycle Fault #2
User guide for Direct Observations equipment use
Maintenance masterdrive siemens
Chapter 31 Battery Systems.
HVI HIPOT TEST SET Pft sERIES.
Quick Reference Parts Guide Introduction
Meeting In A Box Set Up Guide
Hutchinson Hall-Black Box
Hennings Hall-Black Box
Laser 3000™ Operating Instructions
The Crane Control Group
Sony PCM-M10 Recorder Asst. Superintendent for H.R.
Presentation transcript:

Welcome to

The DTS Garage door openers are imported by DTS Security Products CC . We continue to upgrade our products via our suppliers to meet the consumers requirements.

Garage door operator (GDO) Training on DTS600/800 – 12R – 16A

Checks prior to installation of GDO. Ensure that the door is installed properly. Make sure that when the garage door is moving, there are no friction points. The tension springs must be set correctly. For sectional and tip-up garage doors, the tension must be set so that the door in override position must stay were it is when left in the ¼, ½ and ¾ open position. For roll-up garage doors, the tension must be set so that the door in the override position must start to roll down slowly by itself from just above the ½ open position. (Sometimes bottoms weights are required to be fitted at the bottom of the garage door). This is to prevent coiling of the garage door when being closed. The garage door must be properly balanced. The garage door must be level. Should be able to lowered and raise the garage door by hand with ease. Make sure the garage door structure is solid and suitable to be motor driven. Note: It is illegal to automate a Tip up garage door with counter weights on the side of the door.

Installation of GDO. For Sectional Doors. Fit the GDO as horizontal as possible. Have a 220 volt power plug fitted as close as possible to where the motor head will be. Make sure all fittings holding the GDO are secure. Ensure that the chain tension on the GDO is correct. For Tip-up Doors. Fit the GDO with a tilt of approximately 15 degrees with the motor head being the lower part. For Roll up Doors. Make sure the GDO is as close as possible to the adaptor wheel. Fit the GDO with the clamping plate parallel to the floor below the garage door shaft. Have a 220 volt power plug fitted as close as possible to where the Control box will be. Modify the adaptor wheel NOT THE GDO to fit into each other.

Features DTS600/800 (800 to be used for Caravan and double garage doors). 24 volt DC motor designed. Anti crush mechanism. 24 volt battery back up. On board rolling code receiver. (RX). Maximum of 20 remotes. Auto close facility. Manual release facility. Easy to install. Simple programming. Can be used for Sectional, Tip up and Caravan Doors. Safety Infra Red Beams can be connected.

Programming. Open and Close position. Place door in approximately half open position. Make sure that the traveler is engaged to the chain link. Apply 220 volt power to the unit. Keep all persons and property clear from the door. Remove all external connections. Press and hold SET (K1) button until LED displays the figure 1. Press and hold UP (K3) button, the door must move to the open position. Release the button when the door has reached the desired open position. Can be fine set by using UP (K3) and DOWN (K4) buttons. Press and release SET (K1) to store this position. The LED will automatically change to the figure 2. Press and hold DOWN (K4) button, the door must move to the close position. Release the button when the door has reached the desired close position. Can be fine set again by using UP (K3) and DOWN (K4) buttons. The door will now automatically open and close to store the required load force. Replace all external connections, if any. The door is now set for normal operational use. (Note the change on the display)

Manual adjustment on load force for special purposes. Please note that this programming is generally not necessary. Press and hold SET (K1) button until the LED displays the figure 3. On releasing SET (K1) button the force setting will appear on the display, anything from 1 – 9. Press UP (K3) to increase the load to a maximum figure of 9. Or press DOWN (K4) to decrease the force to a minimum figure of 1. Press and release SET (K1) to store your required setting. Should the door meet and hinders it will stop and rebounds 15-20 cm.

Function modes. Activate and De-activate the Infra Red Beams. Make sure that your beams has been installed correctly before activating this function. Press and hold DOWN (K4) button until the LED displays a -. Press DOWN (K4) button once, the LED will display II, beams are now de-activated. Press UP (K3) button once, the LED will display H, beams are now activated. Please note: If beams are activated with no beams fitted, the GDO will open but will NOT close. Press SET (K1) button to store your settings.

Setting of Auto close ON/OFF. IMPORTANT: This function must not be activated if no beams are fitted. Press and hold UP (K3) button until LED displays a -. Press UP (K3) button, the auto close time will increase by 1 minute each time the UP (K3) button is pushed, the LED will display figures 1 to 9 with 9 being maximum. Press DOWN (K4) button to de-crease the time by 1 minute on each push with the minimum being 1 minute. If DOWN (K4) button is pushed until the figure 0 appears, the auto close is then de-activated. Press SET (K1) to store your setting.

Setting of Holiday Lock-out ON/OFF. Press and hold SET (K1) button until the LED displays figure 4. On releasing the button the figure will change automatically to a 1. or a 0. Press UP (K3) button to display figure 1, holiday lock-out activated. Press DOWN (K4) button to display figure 0, holiday lock-out de-activated. Press SET (K1) button to store your required setting. To over ride the holiday lock-out, press button no. 3 on the transmitter before the required button on the transmitter to open the garage door. This can only be done with the transmitters supplied with the DGO from DTS Security Products. Example button no.1

Programming of Transmitters. (Max.20) Press and release CODE (K2) button, a red dot on the screen will light up. Press the required button on the transmitter. The Red dot will go off. Press the same button on the transmitter again. The Red dot will flicker a few times and stay off. The LED display will then show a II. Transmitter programmed successfully. Repeat above to program a maximum of 20 transmitters. Please note that button no. 3 cannot be programmed onto the on board receiver. This button is used in conjunction with holiday lock-out. Example button no.1

Master erase Receiver. Press and hold CODE (K2) button, the Red dot will flash 14 times followed by the LED display flashing a letter C 4 times. Release the button. The LED display will then automatically show a II. All transmitters are now deleted.

External connections.

Connecting the battery back-up. Fit the battery on top of the motor head, space provided. Clamp battery down with the 2 provided brackets. Connect the battery terminal wires to the provided wires on the motor head. Allow time for batteries to charge fully. The GDO is now ready to be used as a battery back-up system.

External receiver connections. N/O Trigger N/C Trigger CM Common Receiver 12 - 24v Neg. 12 - 24v Pos.

Infra red beam connections. IR Beam TX 12v Pos. 12v Neg. 12v Pos. 12v Neg. IR Beam RX CM Com. N/C Trig. N/O Trig. If sentry beams are being used, connect N/O Trig to PE.

Connecting of wall mount bracket. Wall mount push button N/O N/O Common

Fault finding

Disconnect external connections (Green connector block). If the GDO now operates, reconnect the externals one at a time until the fault re-occurs. That external unit is then faulty or incorrectly wired onto the GDO. If a line in the middle of the LED display is on and nothing wants to operate. The GDO was put into a none programmable mode. Follow the normal open and close program procedure to over come this problem. If the door closes but will not open, it is in holiday lock-out. Follow the holiday lock-out procedure to unlock the GDO or utilize button number 3 on the DTS transmitter . If the door opens but will not close, the beam function is enabled with no infra red beams fitted. Follow the de-activate procedure to over come this problem, or bridge out the GND and PE connection on the green connector block. If the door closes by itself, the auto close is activated. Follow the auto close procedures to de-activate auto close. Wires from infra red beam Trigger wires, EG: Intercom

Important. The DTS600/800 garage door operator described in this training session is designed for Sectional, Tip-up and Double garage doors. Any other use is considered improper and WILL void the warranty.

End of DTS600/800 training.

Features 12R 24 volt DC motor designed. Anti crush mechanism. Optional 24 volt battery back up. On board rolling code receiver. (RX). Maximum of 20 remotes. Auto close facility. Manual release facility. Easy to install. Works with most roller doors. Operates smooth and quietly. Safety Infra Red Beams can be connected.

Programming. No programming is required for the DTS 12R GDO. Fit the motor to the garage door. Check the motor and limit switch cord length and fit the Control panel box. Connect the motor and limit switch cord to the PCB (Process control board). Remove the side cover on the motor. Close the door manually by hand. Set the back (Bottom) cam to activate the back limit switch. Open the door manually by hand. Set the front (Top) cam to activate the front limit switch. Set dipswitch number 1 to ON “D” disable position. (Auto close OFF). Set dipswitch number 2 to the required position. Standing inside the garage looking at the door. Motor on left hand side of door, dipswitch 2 Down, towards L. Motor on right hand side of door, dipswitch 2 Up, towards R. Push the Red button on the control box to trigger the door. Check and fine set the BACK and FRONT cam to the desired door open and close positions. Motor on left. Motor on right.

Load setting. The load setting for open and close must be set manually by the load pots marked as UP for opening and DOWN for closing. Turning the pots anti clock wise, decreases the load force. Turning the pots clock wise, increases the load force. The open and close load setting must be set individually.

Programming of Transmitters. (Max. 20) Press and release the K1 learning button below the red LED. The LED will go ON. Press and release one of the four transmitter buttons. The LED will go OFF. Press and release the same button on the transmitter again. The LED will flash fast 8 times. That transmitter is now programmed. Repeat the above steps for more transmitters. If the LED on pressing and releasing of the K1 button flashes 4 double flashes, it is an indication that the Receiver is FULL. EG: Button no. 1 K1 Learning button

Master erase Receiver. Press and hold the K1 button, the led will flash 10 slow flashes. All transmitters are now deleted from the on board receiver. K1 Learning button .

External Receiver Connection. 12-24V Pos. 12-24V Neg. Common. Receiver N/O N/C DC power for the External receiver can also be obtained from the battery back-up terminals SP- and SP+

Infra red beam connections. N/C N/O Common. IR Beam RX 12-24V Pos. 12-24V Neg. IR Beam TX 12-24V Pos. 12-24V Neg. DC power for the beams can also be obtained from the battery back-up terminals SP- and SP+

Features 16A (Big brother to the 12R) 24 volt DC motor designed. Anti crush mechanism. Optional 24 volt battery back up. On board rolling code receiver. (RX). Maximum of 20 remotes. Auto close facility. Manual release facility. Easy to install. Works with most roller doors. Operates smooth and quietly. Safety Infra Red Beams can be connected.

Note: The DTS 16A uses the same control panel as the DTS 12R, therefore all programming and setting up are basically the same as the DTS 12R.

Limit switch settings Unlike the 12R cam limits, the 16A limits are set on the worm screw. Follow the same procedures by putting the door manually in the open and close positions, but instead of moving the cams on the 12R, turn the brass setting bushes towards the open or close limit by turning the bushes clock wise or anti-clock wise. Once the limits are set and fine tuning of open and close positions are correct, fasten the turn knobs to prevent the brass bushes from moving of its mark.

End of presentation.