ET 438B Sequential Control and Data Acquisition

Slides:



Advertisements
Similar presentations
Sequential Process Control
Advertisements

SWITCHES, FUSES, & CIRCUIT BREAKERS
Contactors & Relays.
E1 – Electrical Fundamentals
Programming Logic Controllers
Elec467 Power Machines & Transformers
Circuit Protection  Protective Devices – terminate current flow in a circuit.  Located in series within a circuit  Excessive current flow results from.
Introduction To Programmable Logic Controllers
Components & Symbols Used in Electrical Circuits
Logic Control. What is Logic control Logic control is a control based on a logic concept, that is the on-off state of variable and/or equipment Logic.
ELECRICAL CIRCUITS.
Lesson 15: Dc Motor Control Components and Diagrams
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Lecture 6: PLC: Timers and Counters
Chapter 3 Manual Starters.
Chapter 6 Control_relays.
Industrial Machine Control
Electronic component identification In order to identify electronic components from diagrams and data sheets and then select the appropriate electronic.
CHAPTER Wiring Schematics and Circuit Testing 9 Copyright © 2016 by Pearson Education, Inc. All Rights Reserved Automotive Electrical and Engine Performance,
Wiring Schematics and Circuit Testing
Ladder Diagram Symbols Flashcard Exercise Get Started.
Ladder Diagram Symbols. Study the various symbols identified in this presentation. Once you have memorized the different symbols and can name them, take.
Electrical Control Components
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
Unit 4 Symbols.
Logic Functions and Symbols
Prepared by: Engr. Qurban Ali Memon 11ES (SEC- 1 & 2)
DPCL Solid State Device Discrete Control Lecture.
Ladder Concept.
Wiring Schematics and Circuit Testing 7 © 2013 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ Advanced Automotive.
Symbols and Schematic Diagrams
Fluid Power Control.
Electromechanical Relays Mechatronics ECE 5320 Assignment #1 Paul Smart.
Push Button Station and Relay
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Chapter 6.
Lecture 10: Programmable Logic Controllers
Electronic Control Systems Week 3 – Switches and Sensors
Switches Electronics 1 CVHS.
E1 – Electrical Fundamentals
THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE Submitted by:
JC Technology Components.
INDUCTION MOTOR PROTECTION FOR SINGLE PHASING, OVERVOLTAGE AND OVER TEMPERATURE Submitted by:
Relay operation Water level Indicator
Presented by SARAVANA KUMAR . M (EEE III Year) SBM CET
Electrical actuation systems
The Electrical Diagram
Electronic Control Systems Week 4 – Relays and Solenoids
ET 438B Sequential Control and Data Acquisition
Industrial Electronics
PLC Hardware Components.
Programming Timers.
IENG 475: Computer-Controlled Manufacturing Systems
Lesson 14: Introduction To Sequential Control
Manisha Goel, Lecturer, EE Deptt Govt. Polytechnic Manesar
Lesson 19: PLC Programming Techniques
Workbook Section.
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Electromagnetic Devices
EET 323 – Electrical System Design Lecture 4: Wiring Devices
Lesson 15: Boolean Representation of Ladder Diagrams
PROGRAMMABLE LOGIC CONTROLLERS
ACOE347 – Data Acquisition and Automation Systems
Electronic systems 7.
Introduction to Electro-pneumatic
Fluid Power System Electrical Control
Presentation transcript:

ET 438B Sequential Control and Data Acquisition Lecture Notes Part 6 ET 438B Sequential Control and Data Acquisition ET438b-6

Sequential Process Control A process in which one event follows another until a job is completed For a process with N steps Event 1 Event 2 Event N …….. Characteristics 1.) Discrete loads 2.) Product output is in units (cans boxes) 3.) Different equipment modifies the product at each step 4.) Steps are staged ( do step 1 before 2) ET438b-6 et438b-6.pptx

Applications Assembly Line process Conveyor systems Industrial Robots Power protection systems Motor starting and control ET438b-6 et438b-6.pptx

Sequential Vs Process Control Controller Process feedback Setpoint output Feedback is continuous. Controller could be implemented with analog or digital control (DSP) methods Sequential Control Status I/O typically bi-level (on-off) in nature Process Sequential Process Controller Process status I/O ET438b-6 et438b-6.pptx

Devices Used in Sequential Control Inputs: Manually Operated Switches toggle switches- multiple poles multiple positions (on/off) selector switches - sets different operating modes (on/off/auto) Schematic symbols On A On B On B On A Single pole single throw (SPST) Single pole double throw (SPDT) DPDT dashed line indicates mechanical links 3-pole double throw Drawing standard - switches shown in the un-operated or open position ET438b-6 et438b-6.pptx

Inputs-Manually Operated Switches Push Buttons - momentary contact switches Push buttons can be either normally open (NO) or normally (NC). Some types can be stacked to have multiple sets of NO and NC contacts Schematic symbols Actuated Normally open NO Normally closed NC Normally closed ganged with normally open Depressing the button causes all associated contacts to change state. Drawn in un-actuated position. Push buttons usually used to start and stop pieces of equipment in industrial operation ET438b-6 et438b-6.pptx

Mechanically Operated Switches Switches used to sense the operation of devices Limit switches - switches that change contact state when there is movement. Detect if part of machine has reached a specific location. Usually physically linked to machine Types Contact type - roller arm, wand type Proximity type - detect ferrous and non-ferrous metals ET438b-6 et438b-6.pptx

Mechanically Operated Switches Limit Switches Schematic symbols NC limit switch NO limit switch NO held closed limit switch Limit switches can have multiple contacts of both the NO and NC type that change state when actuated Drawing standard - switch drawn in the un-operated position ET438b-6 et438b-6.pptx

Mechanically Operated Switches Used as sensors to detect conditions of operation NO NC NO NC NC NO Temperature switches (similar to thermostat) Pressure switches Types for both state change on rising or falling pressure Level or float switches Types exist that change contact state for either rising or falling level Flow Switch (NO) changes state when flow reaches preset value (can produce pulses proportional to flow) ET438b-6 et438b-6.pptx

Control Devices Control Relays - implement Boolean logic using electromechanical relays and contacts. NC contact Schematic symbols NO contact Drawing convention: control relay contacts shown with coil de-energized. Contacts associate with coil have similar identification Coils and contacts need not be located together physically on schematic Control Relay Characteristics Coil voltage, current type (ac,dc), power consumption, pull-in power, I/V ratings of contacts, coil time constant ET438b-6 et438b-6.pptx

Control Relay Characteristics Coil voltage - operating range (+110% -80%) typical values - 24, 48, 125 250 Vdc 48 120, 480 Vac Low supply voltage causes relays to “drop out” Coil Power - given in VA. Determine power capacity of supply. typical 50 - 100 VA per coil Pull-in Power - power necessary to move relay armature and close contacts. ET438b-6 et438b-6.pptx

Pull-in Power and In-Rush Current coil inrush I time I armature seated holding current When energized, coil requires 7-10 times rated (Reluctance high due to air gap) ET438b-6 et438b-6.pptx

Electromechanical Timers/Counters Schematic symbols: note either coil type is used Off-delay action - TR de-energized, contacts change state after set time interval On-delay action - TR energized, contacts change state after set time interval on-delay timer off-delay timer Contact symbols determine the type of timer action ET438b-6 et438b-6.pptx

Electromechanical Counters Typically have three connections on schematic symbol for coil. Takes pulse input (contact closures) from other devices. Schematic symbols Contacts CTR change state after the preset number of counts are accumulated by CTR coil symbol CTR device may also take a reset input that clears counter. ET438b-6 et438b-6.pptx

Final Control Devices Solenoid- electromechanical device which uses a movable iron core to actuate another device typical applications- valve control (liquid, pneumatic hydraulic) Schematic Symbol ET438b-6 et438b-6.pptx

Final Control Devices Motor Controllers- integrate switching with thermal overload protection Schematic symbol 3-phase motor line thermal overloads control coil ET438b-6 et438b-6.pptx

Basic Motor Control Starter matched to motor by NEMA (National Electrical Manufacturers Association) size Thermal overloads result from: 1.) Attempting to drive mechanical load greater that motor rating 2.) High inertia loads with long acceleration times 3.) Motor mechanically unable to turn 4.) Low motor terminal voltage 5.) Excessive starting and stopping (jogging) (heat build-up due to high I) 6.) Loss of one of the three phases (single phasing) ET438b-6 et438b-6.pptx

Miscellaneous Devices Panel Lights - Incandescent or LED fuse white green red Size in amps indicated near symbol Resistor used to prevent moisture buildup and component icing in outdoor equipment heater ET438b-6 et438b-6.pptx

Ladder Diagrams Inputs Rung Number Outputs Description Number at each rung indicate the rung numbers where the output coil’s contacts are located Circles on each side of contact indicate that it is physically separate from the other devices in the schematic ET438b-6 et438b-6.pptx