Sunday Case of the Day Category Physics Question:

Slides:



Advertisements
Similar presentations
Receiver Bandwidth affects signal-to-noise ratio (SNR)
Advertisements

Assessment of tumoural ADC’s in rectal Tumours using Burst: New methodological Developments SJ Doran 1, ASK Dzik-Jurasz 2, J Wolber 2, C Domenig 1, MO.
MRI Phillip W Patton, Ph.D..
Parameters and Trade-offs
Topics spatial encoding - part 2. Slice Selection  z y x 0 imaging plane    z gradient.
Chemical Shift To do with the different electron environments of protons Results in a shift of resonant frequency which affects the image e.g. fat (CH.
MRI Artifacts This presentation is available at: Zhuo, J. et al. Radiographics 2006;26: , AAPM/RSNA.
Functional Brain Signal Processing: EEG & fMRI Lesson 12 Kaushik Majumdar Indian Statistical Institute Bangalore Center M.Tech.
Psy 8960, Fall ‘06 EPI, Part 11 Pulse sequences Nyquist ghost Chemical shift –FLASH –EPI.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D..
Tissue Contrast intrinsic factors –relative quantity of protons tissue proton density –relaxation properties of tissues T1 & T2 relaxation secondary factors.
Medical Imaging Systems: MRI Image Formation
Principles of MRI Physics and Engineering
The comparison of MRI imaging In 3.0 T & 1.5T By a.r.shoaie.
Correcting for Center Frequency Variations in MRSI Data Using the Partially Suppressed Water Signal Lawrence P Panych, Ph.D., Joseph R Roebuck, Ph.D.,
Introduction Magnetic resonance (MR) imaging is recognised as offering potential benefits in the delineation of target volumes for radiotherapy (RT). For.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D.. Image Detail and Noise Two image characteristics that reduce the visibility of anatomy/pathology –Blurring.
March 22, 2011 Issac Yang Supervisor: Charles McKenzie, PhD
Figure 3. Log-log plot of simulated oscillating phantom, assuming a Gaussian-shaped field. Field constants a 1 =a 2 =0.1. The data initially plateau, then.
1 Chemical Shift Image B shows a more marked amount of chemical shift, why can this be? Chemical shift is an artefact which occurs because fat and water.
Conclusions Despite being able to acquire successfully high resolution images of radiation dose, image quality is limited by hardware problems. Upgrading.
MRI Physics: Spatial Encoding Anna Beaumont FRCR Part I Physics.
Substantial signal dropout was observed in arterial spin label (ASL) images, acquired at 3T in a young female patient three-months after mild traumatic.
Sunday Case of the Day How does the presence of the object impact patient dose? A. Increases by 20% - 50% B. Increases by 3% - 5% C. No Change D. Decreases.
Sunday Case of the Day Physics
Sunday Case of the Day Physics
Monday Physics Case of the Day Answers (1 of 3) Paul E
Sunday Case of the Day Physics
Monday Case of the Day Physics
Magnetic Resonance Imaging: Physical Principles
Assume object does not vary in y
Wednesday Case of the Day
Sunday Case of the Day Physics (Case 1: MR)
Wednesday Case of the Day
MRI Pulse Sequences: IR, EPI, PC, 2D and 3D
Tuesday Case of the Day Physics
A–C, Images of total sodium content for a patient with a glioblastoma of the mesial frontal lobe. A–C, Images of total sodium content for a patient with.
Demonstration of the creation of a patient-specific brain mold for minimizing tissue distortion during fixation. Demonstration of the creation of a patient-specific.
Intraosseous temporal bone meningioma in a 45-year-old woman who presented with left-sided hearing loss and tinnitus. Intraosseous temporal bone meningioma.
3T-versus-7T DTI with 36 diffusion-encoding directions at b = 3000 s/mm2 and 2.0 × 2.0 × 2.0 mm isotropic voxel resolution. 3T-versus-7T DTI with 36 diffusion-encoding.
A–C, Case 1. A–C, Case 1. Typical white matter changes involving the corpus callosum and the pyramidal tracts (A and C, arrows), dilation of the lateral.
A, Measurement of the angle between the TS-OP line and the hard palate in the lateral scout view of the brain CT (black arrow). A, Measurement of the angle.
48-year-old man with a 2-month history of recurrent episodes of unsteady gait, visual loss, tinnitus, left arm paresthesia, and frontal headache. 48-year-old.
MRI: From Protons to Pixels
FLAIR scan, FA map, and fiber tracking in a 38-year-old patient with TBI who was imaged 2 weeks after the initial trauma. FLAIR scan, FA map, and fiber.
A, A 50-year old female patient with acute ischemic stroke (AIS), visible as an area of reduced diffusion (dark region) on the apparent diffusion coefficient.
Patient 1, a 15-day-old neonate who presented with encephalopathy
Axial view MR images of the head, obtained at the time of second presentation.A, T1-weighted MR image (400/15) shows thickening of the dura overlying the.
MR images of Taylor’s FCD with balloon cells
Same patient as shown in figure 3.
Axial MR image (10,002/142) obtained when the patient was aged 12 days demonstrates ventricular size and sulcal prominence have increased since the study.
A 74-year-old man who presented to the emergency department after a fall with left-sided weakness. A 74-year-old man who presented to the emergency department.
Patient 10. Patient 10. A, Coronal high-resolution CT scan, obtained through the sphenoid sinus, shows a defective intersphenoid septum deviated to the.
KD involving the postauricular area and occipital scalp in an 11-year-old boy. KD involving the postauricular area and occipital scalp in an 11-year-old.
T2-weighted MR imaging appearance of a healthy 60-year-old woman (A), a 66-year-old woman with idiopathic Parkinson disease (B), and a 16-year-old female.
Coronal postcontrast T1-weighted image of the orbits in patient 1 demonstrates a heterogeneously enhancing ovoid lesion involving the right medial rectus.
Sagittal T1-weighted MR image of the pituitary gland in a term neonate (born at gestational week 38) obtained near term (corrected age of 39 weeks; 7 days.
Case year-old patient with diabetes initially presented to an outside facility with meningitis and underwent serial imaging demonstrating the imaging.
MR images of the patient’s head, obtained on hospital day 17, 3 days after renormalization of overcorrected hypernatremia.A, FLAIR image now demonstrates.
Representative quantitative maps of a patient with brain metastasis.
Patient 10. Patient 10. A 67-year-old man after radiation therapy at an outside hospital for base-of-tongue cancer. A and B, Axial contrast-enhanced CT.
Globally increased ASL signal intensity due to artifact.
Patient 3 was an 8-week-old female infant with a history of seizures that started 3 days before MR imaging was performed. Patient 3 was an 8-week-old female.
Twelve-year-old girl with coinfection of JE and NCC (patient 5).
Left, T1 spin-echo image at 1
Same section position with spin-echo T1-weighted sequences at 1
Two cases with Sylvian fissure SAH
Presentation transcript:

Sunday Case of the Day Category Physics Question: Authors: Miguel Flores MD, Steven Messina MD, John Murray MD, William F Sensakovic PhD Florida Hospital Department of Radiology Question: Increasing which parameter will reduce the demonstrated MRI artifact (ignore motion)? TR Receiver bandwidth Frequency encode matrix size Static field strength (B0) Figure 1: T2-weighted MR image through the level of the orbits.

Diagnosis: B. Receiver Bandwidth

Correct Answer: B. Receiver bandwidth: Patient has a remote history of left retinal detachment with subsequent silicone oil retinopexy. Silicone oil protons resonate at a lower frequency than water protons. Since spatial positioning of tissue (mapping) on the final image depends on resonant frequency during readout, the lower resonant frequency of silicone will cause it to be artificially displaced from its true position along the frequency encoding direction. This results in a dark rim along one side of the silicone oil, and a light rim on the other. Other answers: Incorrect. TR will not impact chemical shift artifact Correct. Increasing the receiver bandwidth increases “bandwidth per pixel,” thus reducing the magnitude of the chemical shift artifact Incorrect. Considering bandwidth per pixel is calculated by dividing [total receiver bandwidth] / [frequency encode matrix size (pixel)], increasing the frequency encode matrix size will decrease “bandwidth per pixel” Incorrect. Increasing the B0 field will increase magnitude of the chemical shift artifact

Figure 2: T2-weighted MR images demonstrate left intraocular, left para-chiasmatic, and left intraventricular (frontal horn of the left lateral ventricle) silicone oil with associated chemical shift artifact along the frequency-encoding direction (arrows). Ocular motion artifact along the phase-encoding direction is also noted.

Correct Answer: 61 kHz/px 122 kHz/px In vitro preparation of silicone oil on water. At the interface between silicone oil and water (arrow) results in a large band when scanned at a bandwidth of 61 kHz/pixel (left) the defect is roughly halved when scanned at 122 kHz (right). 61 kHz/px 122 kHz/px Increasing receiver bandwidth can reduce artifacts and scan time, but at the expense of signal to noise ratio as demonstrated in the above images.

Intraocular Silicone Oil Correct Answer: How big is the chemical shift? The difference in resonant frequencies between silicone oil and water protons is ~4.4 ppm. Consequently, silicone will have a frequency that is ~280 Hz* slower than water at 1.5T and ~560 Hz slower at 3T. If a sample protocol results in a bandwidth per pixel of 140 Hz/pixel, then a 2 pixel chemical shift can be anticipated at 1.5T (280 Hz / 140 Hz/pixel = 2 pixels). Doubling the receiver bandwidth with an unchanged matrix will double the bandwidth per pixel and decrease chemical shift by a factor of 2 (280 Hz / 280 Hz/pixel = 1 pixel).   Intraocular Silicone Oil Vitreous Silicone 140 Hz/pixel 1 Pix 2 Pix 280 Hz/pixel Figure 3: Schematic demonstration of chemical shift magnitude in response to changes in receiver bandwidth * 4.4 ppm*42.6 MHz/T*1.5 T = 281 Hz

References/Bibliography: Acknowledgments We would like to thank ophthalmologist Dr. My Hanh Nguyen from Winter Park, FL for her assistance in obtaining a sample of silicone oil used in practice. Additionally, we would like to thank Florida Hospital Radiology Specialists of Florida (RSF) for the scanner time utilized in the acquisition of included images. References/Bibliography: Elster AD. Chemical Shift Artifact.  2017 [07/24/2017]; Available from: http://mri-q.com/chemical-shift-artifact.html. Mathews VP, Elster AD, Barker PB, et al.  Intraocular silicone oil: in vitro and in vivo MR and CT characteristics. AJNR Am J Neuroradiol 1994;15:343-7.  Williams RL, Beatty RL, Kanal E, Weissman JL. MR imaging of intraventricular silicone: case report. Radiology. 1999;212(1):151-4.