Fluoroscopic Unit Thomas Edison 1896.

Slides:



Advertisements
Similar presentations
Advanced Biomedical Imaging Lecture 3
Advertisements

Chapter 11 Prime Factors.
Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
Dental X-ray Machine 118 Radiology.
ACVR Artifacts Artifacts of Diagnostic Radiology
Fluoroscopy Equipment Operation
Oscilloscope. 1.Electron guns 2.Electron beams 3.Focusing coils 4.Deflection coils 5.Anode connection 6.Mask for separating beams for red, green, and.
X-RAYS IN MOTION “Viewing dynamic studies of the human body”
Basic Concepts of Other Imaging Modalities
X-Ray Production & Emission
Fluoroscopy: Viewing Systems
Fluoroscopy Equipment
FLUOROSCOPY.
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
Special Imaging Systems
F luoroscopy. 2 Fluoroscopy system 3 Different fluoroscopy systems  Remote control systems Not requiring the presence of medical specialists inside.
Fluoroscopy Intro to EQUIPMENT
INSTRUMENTATION. ELECTRICAL REQUIREMENTS AND EFFICIENCY  Effective voltage  High frequency inverter technology (over 10,000Hz)  Constant potential.
ECE 5th SEMESTER Subject Consumer Electronics (CE)
FLUOROSCOPY EQUIPMENT
Quality Control.
Dr Mohamed El Safwany, MD.
CHAPTER 3 EQUIPMENT OPERATION AND QUALITY CONTROL
Fluoroscopy Equipment. Introduction Fluoro: is dynamic radiographic examination Fluoroscopy is primarily domain of the radiologist The role of radiographer.
Scanning Electron Microscope (SEM)
Equipment Operation and Maintenance. Grid-controlled tube Designed to turn on and off rapidly, providing short precise exposures Use in fluoro and in.
Chapter 2 The X-ray Beam.
Factors affecting CT image RAD
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Appendix H: Chapter 40: Fluoroscopy
What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the.
Chapter 3: Factors of Image Quality 1. Interlaced vs. progressive scanning 2. Matrix size 5. Field of view (FOV) 3. Vertical resolution 4. Horizontal resolution.
PRINCIPLES OF TECHNIQUE AND EXPOSURE
TELEVISION CAMERA TUBES
 Display Devices Display Devices  Display Hardware  Components of CRT Components of CRT  Refresh CRT Refresh CRT  Electron Gun  Focussing system.
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Medical Equipment Technology Department 1 Introduction to Biomed. Imaging Systems Lecture No.5-6 Dr. Yousif Mohamed Y. Abdallah.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
FLUOROSCOPY & IMAGE INTENSIFICATION Sergeo Guilbaud, RT School of Radiologic Sciences.
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
Patient is placed between X-ray tube and silver halide film.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Chapter 4: Diagnostic X-Ray Production
Resident Physics Lectures
Laboratory equipment Lecture (3).
Oscilloscope.
X-ray Production Sharif Qatarneh Medical Physics Division
IMAGE ORTHICON.
Part No...., Module No....Lesson No
X-Radiation.
Exposure Factors Chapter 4
Imaging System Components
Equipment Operation and Maintenance
Scintillation Counter
Resident Physics Lectures
Fluoroscopic Brightness Control Systems
Fluoroscopic Image Intensifier Image production
Fluoroscopy: Viewing Systems
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy – Viewing Systems Optical Mirrors TV Camera & TV Camera Tubes Charge Coupled Devices (CCD) Based on: Principles of Radiographic Imaging, 3rd.
Fluoroscopy – Viewing Systems TV Monitors
What makes a Quality Image
Flouroscopic imaging.
Fluoroscopic Image Quality Considerations
Fluoroscopic Image Intensifier Image Production
Fluoroscopic Image Quality Considerations
Brightness Control Systems
Generation of X-rays Q&A
Presentation transcript:

Fluoroscopic Unit Thomas Edison 1896

Fluoroscopy Dynamic imaging Spot films 3-5 mA kVp and mA determine brightness level Automatically adjusted during fluoro by automatic brightness control (ABC)

Image Intensifier Electronic vacuum tube Converts the remnant beam to light, then to electrons, then back to light Remnant beam-light electrons light light intensity in the process Parts Input Phosphor Photocathode Electrostatic focusing lenses Accelerating anode Output phosphor

Input Phosphor Made of Cesium iodide Absorbs the remnant x-ray photon energy and emits light in response Side toward the tube Side toward the patient Bonded to the curved surface of the tube

Photocathode Made of cesium and antimony compounds These metals emit electrons in response to light stimulus in a process called Photoemission Bonded directly to the input phosphor Curved so that all of the electrons emitted travel the same distance to the output phosphor

Electrostatic Focusing Lens Negatively charged plates along the length of the image intensifier tube Repel the electron stream, focusing it on the small output phosphor

Accelerating Anode Sets the electron stream in motion at a constant velocity Maintains constant potential of 25kV

Output Phosphor Silver-activated zinc cadmium sulfide Absorbs electrons and emits light in response End result An increase in image intensity and brightness

Magnification Mode Focal point is shifted farther from output phosphor Voltage to electrostatic focusing lenses is increased. The increase tightens the diameter of electron stream and focal point is shifted Increase in pt dose Spatial Resolution is improved Smallest structure that may be detected Measure in line pairs/mm Magnification If fewer electrons are incident on the output phosphor , the output intensity decreases What does the ABC do to compensate? (increase radiation) What does this do to pt dose? (increase)

Magnification 9-inch Input” button, you’ll see that an image of the figure appears smaller and inverted near the output phosphor – this simulates a normal mode in fluoroscopy. When you click on the “6-inch Input” button, the input phosphor size is reduced, the output phosphor size remains the same and the image is magnified.

Intensification Principles Brightness gain(Conversion Factor) Ability of image intensifier tube to convert x-ray energy into light energy & increase the brightness of the image Minification gain x flux gain Flux gain Ratio of #light photons at the output phosphor to the # of light photons emitted in the input phosphor Represents the tubes conversion efficiency Conversion factor Luminance at output phosphor input exposure rate Appears brighter because the same # of electrons are being concentrated on a smaller surface area What do you think happens to the brightness as the tube ages? (deteriorates) How do you compensate for the decrease in brightness? (use more radiation) What happnes to pt dose? (increase)

image appears brighter Minification gain – the brightness gain caused from a decrease in size from the input to the output phosphor image appears brighter Input phosphor daimeter2 / output phosphor diameter2

Automatic Brightness Control (ABC) Adjusts and maintains the overall image density and contrast during fluoroscopy Determined by the brightness control setting that the radiographer sets Contrast and density By automatically adjusting kVp and mA or both

Distortion Misrepresentation of true size or shape of an object Caused by the curved shape of the photcathode Inaccurate control or focusing of electrons released at photocathode Pincushion appearance Vignetting-loss of brightness around the edge of the fluoroscopic image caused by the curve of the photocathode Loss of brightness

Viewing Systems The signal is sent to a television monitor for viewing through the Vidicon tube Diode tube in a glass envelope Connected to the output phosphor Digital fluoroscopy Computerized images from output phosphor No need for overhead/spot films

Camera Tube

Cathode Cathode Electron gun Provides continuous stream of electrons Control grid Forms the electron stream into a beam

Anode Anode Face plate Signal plate Target