Prepared by : Khansa’ Mohd Rashid Norhana Rahmat
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Recent Advances in IOP measurements
SAMIR AL-MANSOURI, MD. e.g. - cataract - glaucoma - macular degeneration - diabetic retinopathy Chronic = slowly progressive visual loss Major causes:
Assessment and Management of Patients With Eye and Vision Disorders
Walter Huang, OD Yuanpei University Department of Optometry
بنام خداوند بخشنده مهربان
The Canadian Association of Optometrists
Barrow, Brantley, Fredde, Gillispie
INTRAOCULAR PRESSURE LECTURE
How The Eye Works Insert name/ Practice name/ Logo here if desired.
OPEN ANGLE GLAUCOMA Frank J. Weinstock, MD, FACS Professor of Ophthalmology- NEOUCOM Canton, Ohio USA.
Comparison of the Diaton Transpalpebral Tonometer Versus Goldmann Applanation R. S. Davidson 1 ; N. Faberowski 2 ; R. J. Noecker 3 ; M. Y. Kahook 1 1.
Eye care basics and optical options
Understanding Amblyopia
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
ARAVIND EYE CARE SYSTEM Aravind Eye Hospital & Postgraduate Institute of Ophthalmology ARAVIND EYE CARE SYSTEM Aravind Eye Hospital & Postgraduate Institute.
Methods of measuring intra ocular pressure. What is intra ocular pressure ? Definition Intra ocular pressure refers to the pressure exerted by the intra.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Presents: Diaton Tonometer Tonometry through the Eyelid! September 2006.
Keloysius Mak. Non-Myopic Eye  Light converges on the retina, producing a clear and sharp image.
Glaucoma and Penetrating Keratoplasty : Incidence, Risk Factors, and Outcomes Sonika Gupta Consultant Ophthalmology Max Eye Care New Delhi, India Author.
In The Name Of God.
Comparison of the Diaton Transpalpebral Tonometer Versus TonoPen- Applination Theodore H. Curtis, M.D.1, Douglas L Mackenzie, M.D.1, Robert J. Noecker.
Dr. Abdullah Al-Amri Ophthalmology Consultant
Glaucoma.
Chronic Visual Loss. CHRONIC VISUAL LOSS 1. Measure intraocular pressure with a tonometer 2. Evaluate the nerve head 3. Evaluate the clarity of the lens.
Types of Eye Care Specialists and the Tools They Use.
Examination techniques in ophthalmology E. Vlková et al.
TONOMETER.
PRIMARY OPEN ANGLE GLAUCOMA PROF.DR.ÖZCAN OCAKOĞLU.
Glaucoma Madhav Vempali Vempali Medical Ltd. Glaucoma The healthy eye Light rays enter the eye through the cornea, pupil and lens. These light rays are.
CONGENITAL GLAUCOMA PROF.DR.ÖZCAN OCAKOĞLU.
The use of automated photo-analysis of pupil size in different levels of ambient illumination to aid diagnosis of Horner syndrome Simon Barnard PhD FCOptom.
(Relates to Chapter 22, “Nursing Management: Visual and Auditory Problems,” in the textbook) Copyright © 2011, 2007 by Mosby, Inc., an affiliate of Elsevier.
Glaucoma “ The Sneak Thief of Sight." Julie DeMore Professor Don Williams NS215G.
Basic Examination of the Eye for primary healthcare providers
SUBACUTE ANGLE CLOSURE MISDIAGNOSED AS MIGRAINE / CHRONIC HEADACHE IN MIDDLE AGED SOUTH INDIAN POPULATION Poornima Kandasamy1, Ajita Sasidharan1 1Glaucoma,
Use of the ICare Home Rebound Tonometer for home self-monitoring of intraocular pressure in a Singaporean population Jeanne Joyce OGLE1, Wai Cheng SOO.
Ocular Manifestations of Diabetes
1.
Ophthalmology – Raised IOP Referrals (Adults only)
Glaucoma Conference Intraocular pressure and tonometry
Intraocular pressure & tonometry
Glaucoma.
Health Assessment Assessment of eye.
Congenital glaucoma/ Buphthalmos
V. Kumar,1,2 M. Frolov,1 E. Bozhok,2 G. Dushina1
A NEW INTRACANALICULAR DEVICE TO TREAT OPEN-ANGLE GLAUCOMA
Direct Ophthalmoscopy
Assessment of the Eye and Vision
Ophthalmic History & Examination Saeed Alwadani, MD Assistant Professor Consultant Ophthalmologist College Of Medicine King Saud University 20/12/2015.
“Exam” Module Objectives
OPTO 4101: Refraction1 Difficulties in retinoscopy
INTRODUCTION TO GLAUCOMA
Glaucoma Clinical features and management
The Congenital ((Developmental Glaucomas
R. S. Davidson1; N. Faberowski2; R. J. Noecker3; M. Y. Kahook1 1
Hong A, Boehlke CS, Afshari NA, Kim T Duke University Medical Center
Direct Ophthalmoscopy
Glaucoma Introduction DR ANUPAMA .B.
Examination Techniques for Accuracy and Efficiency
Visual Perception Eye Careers and Exams.
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
CLINICAL APPROACH TO REFRACTIVE ERRORS
Mohamed Abdelrahman Awadalla,FRCS Magrabi Eye Hospital Cairo - Egypt
Presentation transcript:

2/24/2013

Examination under General Jahangir sadeghi md 2013 - 1391 2/24/2013

Anesthesia in childhood patient with Glaucoma. The mechanisms of glaucoma in childhood is often different from those seen in older patients. Clincian must be familiar with additional information for the evaluation and care of childhood glaucoma patients. 2/24/2013

When enlargement of the cornea is associated with a deep anterior chamber glaucoma should be strongly suspected. The baby may be noticed to shy away from light or bury his head against his parent to prevent exposure to light . Clouding of the cornea is the most frequent physical abnormality. After age 4 years, glaucoma is most frequently detacted for decreased uncorrected visual acuity related to myopia. 2/24/2013

2/24/2013

The Office Evaluation Before E.U.A the Office Evaluation of infants with suspected glaucoma is an important step in their evaluation. 2/24/2013

E.U.A for childhood glaucoma 1- Antiglaucoma medication either locally or systemically should be stopped 12h. Before general anesthesia. 2- Barbiturates & Narcotics should be given before examination those lower IOP. 3- Atropine in the usual dosage is not contra indicated. 4- In the past ethyl ether with nitrous oxide was routine. 5- Halothane decrease IOP IOP measurements should be made unly after the patient is relaxed. Never when moving the eyes struggling. 2/24/2013

5 steps in E.U.A External examination Pressure measurements Corneal diameter measurements Gonioscopy Ophthalmoscopy 2/24/2013

2/24/2013

External examination Evaluation of the corneal luster and clarity Evaluation of the corneal epithelium Evaluation of the Descemet’s m. not all leteaks in Descemet’s m. are caused by infantile glaucoma. (forceps injury at birth) 2/24/2013

Breaks due to glaucoma are: Multiple Curved Horizontal 2/24/2013

Pressure measurements Tonometry is performed before Gonioscopy- IOP remain undisturbed Methods of tonometry Schiotz- indentation Applanation – flatten the cornea Goldman Perkins applanation The eye should be still and in the primary position. 2/24/2013

2/24/2013

Schiotz tonometry – older method Advantages Portability Ease of use Low cost 2/24/2013

Accuracy of measurement is limited by Variation in corneal curvature Rigidity and volume of the eye Rarally used in clinical practice Applanation tonometry Gold standard for measuring IOP Perkins applination in infants under general anesthesia Pneumatic tonometry 2/24/2013

PneumatiC toNOMETER Valuable for measuring IOP after Corneal transplantation Corneal scaring Corneal edema Corneal irregularity 2/24/2013

Tonopen is a hand-held device in accordance with the principle of Mackay-Mary tonometry To measure the pressure applied via a plunger to flatten a small area of cornea “1.5mm” Diameter. A variation of Glaucoma tonometer is the noncontact or air-puff tonometer. 2/24/2013

2/24/2013

Corneal diameter measurement To measure the diametric distance from nasal limbus to temporal limbus. Evaluating the severity and control of glaucoma in infants and children less than 2 years of age. Normal range of corneal diameter in infants is between 9.5-10 mm increasing to 11.5-12 mm at one year of age and as much as 12.50 in the first 3 years. Under one year of age diameters of 12-12.50 mm are suggestive of abnormal enlargement. 13 mm or more at any time in childhood is strongly suggestive of abnormality 2/24/2013

Gonioscopy If the cornea is clear, Gonioscopy is performed by using koeppe Gonioscopy lenses of proper size and a hand- held binocular microscope Gonioscopy findings in infants and young children differ significantly from those of adults. 2/24/2013

Ophthalmoscopy Direct ophthalmoscopy is the best For infants & children Optic nerve head evaluation is crucial in ophthalmoscopy Cupping of the nerve head from glaucoma in infants and children appears similar to that in adults. Myopia is a common accompaniment of enlargement of the eye in infantile glaucoma. 2/24/2013