Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR.

Slides:



Advertisements
Similar presentations
The New Generation of Operating Theatres Colin Dobbyne
Advertisements

Contents: Cover
A New Generation of Surgical Technique: Telesurgery Using Haptic Interfaces By Sarah L. Choy ~ A haptic interface is a force reflecting device which allows.
Technology in Healthcare Identify methods and types of data collected in healthcare.
UCSF Teaching and Learning Center: interprofessional health education Kanbar Simulation, Clinical Skills and Telemedicine Center New Technology-enhanced.
KORSCH Tablet Compression Technology
PROSTATE CANCER da Vinci Robot Surgery Cedric Emery, MD. FACS
THE DICOM 2013 INTERNATIONAL CONFERENCE & SEMINAR March 14-16Bangalore, India Surgical Picture Archival Communication System (S-PACS) SGPGI, Lucknow Case.
SV Line d.o.o.1 Pause (S) Continue (N).
Working for the future - today
AIR CONDITIONING ACCESSORIES
DISTINCTIVE DIFFERENCES Rousseau vs. ____________.
KOREA KIYON COMPANY PROFILE. COMPANY PROFILE Korea Kiyon Company, established in 1985, with the highest quality and most technology advanced inert atmosphere.
Photo Chemical Etching Presentation.  Since 1977, Lancaster Metals Science Corporation has met industries' need for precision metal parts and components.
Wel Handy Mini For horizontal and vertical (down) fillet welding operations.
Robot-Assisted Laparoscopic Surgery - da Vinci System *Some of the slides adopted from: Amanda Neves University of Rhode Island Department of Computer,
Product Presentation. 2 Quantum2 - Product positioning  An innovative, unique and powerful solution.  The most modular printing and encoding system.
Efficient flexibility in room management with SAUTER EY-modulo.
© M. Rauterberg, Intelligent Home-Work Environments Matthias Rauterberg Department of Industrial Design Technical University Eindhoven (TU/e)
The PAC System By Andi Sherman CIS Spring Intro to Radiology Radiology is a fast growing area of the health profession in most hospitals and private.
Graphics, Hypermedia, and Multimedia 7.  2001 Prentice Hall7.2 Chapter Outline Focus on Computer Graphics Dynamic Media: Beyond the Printed Page Interactive.
With over 60 years experience Mondial Forni ensures the highest baking quality and maximum reliability in their ovens. The Ciclomondial combustion gas.
Chapter Seven Graphics, Multimedia, and Hypermedia.
Robotic Surgery and Surgical Simulation
Viewing the Digital Image
DUE Security and Fire Alarm Systems LEARNING OUTCOME 7B Describe design overview and location considerations.
CONTENTS INTRODUCTION HISTORY TYPES OF ROBOTIC SYSTEM WORKING OF ROBOTIC SYSTEMS ADVANTAGES LIMITATIONS CONCLUSION.
Picture Archiving and Communication System (PACS) -Krystal Kerney and Hui Pan.
Overview  In today’s day and age, new technology is constantly being made. Computers in particular have become a critical part of our every day lives.
CAMERA DRIVING SYSTEMS, OPTIMAL FEATURES AND EVOLUTIONS CAMERA DRIVING SYSTEMS, OPTIMAL FEATURES AND EVOLUTIONS Marco Maria Lirici EAES Technology Symposium.
Smart Guard of Your Data Storage EXAGATE monitors, manages and warns for you.
Introduction To Digital Radiography And PACS
Imaging Informatics and PACS
The machine is built to comply with the accident prevention, hygiene and electric standards in force. MODUL SERIES MODULAR DECK OVENS Control panel features:
Telemonitoring of chronic diseases AAL JP Call 6 Central InfoDay – Brussels, 6 February port Saint-Etienne Toulouse, France Director:Francis.
INTERACTIVE LCD TOUCH SOLUTIONS. Simplified presentation technology for the classroom or meeting space Expectations for technology in classrooms and businesses.
High Sensitivity Smoke Detection
1 Security Integration and Esgraf sales presentation 01/2015.
Archival information system ARHiNET Croatian national archival information system Vlatka Lemić Croatian State Archives, Croatia.
Setting up a hybrid suite: truth or myth? Giuseppe Biondi Zoccai, MD University of Modena and Reggio Emilia
Prepared by Stuart Boekeloo. Aleydis Centers LLC has the mission of increasing access to care while decreasing costs for certain segments of the population.
CPSC 875 John D. McGregor Robotic Surgery. references p=&arnumber= &userType=inst.
Integrating the Healthcare Enterprise How to Purchase IHE Conformant Systems John Paganini Guardian Healthcare.
Unit 1: Recognizing Computers Lesson 1: Computers All Around Us Computing Fundamentals Using Windows XP – IC³ Module A.
Medical Imaging Lection 3.
Author: Tatsuya Yamazaki National institute of Information and Communications Technology Presenter: Samanvoy Panati.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
Medical Imaging Lection 3. Basic Questions Imaging in Medical Sciences Transmission Imaging PACS and DICOM.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
I-SNAKE. o WHAT IS I-SNAKE? o COMPONENTS OF I-SNAKE o WHAT IS THE PURPOSE OF NEW CARDIO ARM: o HOW DOES I-SNAKE WORKS? o DEVICE DESIGN o TESTING PROCESS.
ETERE NUNZIO The ultimate end-to-end solution for your NewsRoom.
Easy FlowTM and Smart FlowTM
Computers and Medical Technology The Future of Computers in Medicine.
MOBILE CART & STAND SOLUTIONS Milestone AV Technologies Ltd.
History of digital radiology 1980 Kinos L.T. ET all developed a portable radiographic X-ray camera made of tantalum and aluminum. Digital radiography.
By Prashil Patel.  It is designed to facilitate complex surgery using minimally invasive approach.  The system is controlled by a surgeon from a console.
It’s…….
Integration Systems Integration Products Key Benefits: Ergonomics
C1300 advanced circular chart recorder
Cleanrooms for life science industry
Tiny Surgeons Robots May Do Work Within Body
DELLSOFT Technologies Pvt. Ltd.
Haeger VS PEM.
Digital Interactive Mirror
KeyGuard Key Management System
LEADER ULTRASONIC CO., LTD
Technology in Healthcare
Robotic surgery Atefeh Jannatbabaee
Presentation transcript:

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR Integrated-OR Hybrid-OR Robotic-OR Modular-OR Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR Topics: - Telemedicine - Multimedia (Cameras, Displays) - linked to: -HIS Hospital Information System -RIS Radiology Information System -PACS Picture Archiving and Communication System -LIS Laboratory Information System

Digital communication by hospital IT or Video Distribution System is the basis of the telemedicine system. It collects and organizes the information of all connected imaging devices required for each procedure. The data of the imaging devices can be displayed by different monitors at any place and digitally archived. This means that the system fulfils all requirements for state of the art medical telecommunications: efficient application in the OR to rapid information exchange interdisciplinary cooperation research training Digital-OR

Integration of existing image and data sources The telemedicine system integrates the existing image material quickly and continuously in the OR process. Be it endoscope, microscope, image intensifier, OR light camera, PACS or vital data Digital-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR Digital-OR Integrated-OR Hybrid-OR Robotic-OR Modular-OR

Integrated-OR Digital OR + Centralized control of devices in the OR Manage endoscopic and peripheral devices, e. g. Room- + OR-Light, OR-Table via dedicated IT-Interfaces View, display, document and communicate information from video and other data sources in and out of the OR.

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR Digital-OR Integrated-OR Hybrid-OR Robotic-OR Modular-OR

Operating Theatre + Imaging device, e.g.: Angio-System CT MRI Hybrid-OR

Most Hybrid-OR combine a complete cardio/angio workstation with a cardiovascular OR. Similar workstations can be used in neuro angiography ORs.

Hybrid-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR Digital-OR Integrated-OR Hybrid-OR Robotic-OR Modular-OR

Robotic-OR (Intuitive Surgical) Example: da Vinci Surgical System by Intuitive Surgical Surgeon Console Patient-side Cart Video System

Example: da Vinci Surgical System by Intuitive Surgical The da Vinci Surgical System consists of an ergonomically designed surgeons console, a patient-side cart with four interactive robotic arms, the high- performance InSite® Vision System and proprietary EndoWrist® Instruments. Powered by state-of-the-art robotic technology, the surgeons hand movements are scaled, filtered and seamlessly translated into precise movements of the EndoWrist Instruments. The net result: an intuitive interface with breakthrough surgical capabilities. Robotic-OR (Intuitive Surgical)

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR Digital-OR Integrated-OR Hybrid-OR Robotic-OR Modular-OR

Modular - OR ( Built –in OT )

Wall System made of removable panels (Modules) especially for areas where High-Tec meets Hygiene: OR, Cathlab, CSSD, Laboratory applicable in new buildings as well as refurbishments Modular - OR ( Built –in OT )

Stainless steel : AISI 304 Color solution based on customer choice from NCS or RAL color book Wall panel Modular - OR ( Built –in OT )

2 panels solution Bottom panel standard size 2000x1200 mm Top panel standard size 900x1200 mm Wall panel – OPTION No. 1 Modular - OR ( Built –in OT )

3 panel solution Bottom panel standard size 900x1200 mm Middle installation panel standard size 200x1200 mm Top panel standard size 1800x1200 mm Wall panel – Option No. 2 Modular - OR ( Built –in OT )

Body from aluminum – powder coated Light fittings with dimming function HEPA H14 filtration Laminarizator Laminar flow – main components Modular - OR ( Built –in OT )

Serves from air exhaust from room Body made from zinc coated steel Stainless steel grids AISI 304 or AISI 316 Exhaust channel Modular - OR ( Built –in OT )

Size 600x1200 mm, same as ceiling cassettes Number of light fittings depends on lighting intensity calculation and equability in the OT IP 65 protection Electric stabilizer for dimming function Light fitting control from control panel Service access without using tools Lighting Modular - OR ( Built –in OT )

Size 600x1200 mm Manufactured from 0,8 mm thick metal with surface in RAL 9010 shade OPTION – stainless steel AISI 304 or 316 Tight ceiling Access to installation above the ceiling through revision cassettes in color matching color of the cassettes Cassette ceiling Modular - OR ( Built –in OT )

Any graphic motive can be applied to one or multiple panels Panel has same resistance against the cleaning agents like standard panel Graphic panels Modular - OR ( Built –in OT )

Stainless steel AISI powder coated with mineral wool filling Color solution as requested by customer Full, glassed, with or without radiation protection Blinds – manual, magnetic, electric Hinged, sliding, one wing, two wings Door drives as requested by customer Door systems Modular - OR ( Built –in OT )

Modern solution Hygienic solution Touch less function Full – partial opening Touch less sensor for door systems Modular - OR ( Built –in OT )

Pass through cabinets Cabinets for operating tools Cabinets for sewing material Atypical cabinets – free standing, built-in All cabinets can be done in color solution as requested by customer or in same color shade as the wall panels in the OT. Built-in cabinet Modular - OR ( Built –in OT )

19 inch touch screen Modern look Simple control Language of choice Serviced outside OT Connection through internet 365 days customer support Spare parts available locally Touch screen control panel Modular - OR ( Built –in OT )

Stainless steel AISI 304 (316) Highest quality and focus on details Touch less sensors 1-3 person work stations Custom size Scrub facilities

Installation in accordance with local laws and regulations Realizations approved by local authorities with no comments All other components (doors, cabinets, windows, glassed partitions) are also protected by lead line. Special solutions – lead line installation

Modular-OR (Dräger) Advantages: coordinated AutoCAD plans out of one hand (incl. wall elevations) short construction period reduced noise + dirt during installation highest hygienic standard easy to clean + disinfect, high resistance simple upgrading of installation inside the walls ( reuse of material, no spare parts needed) Modular - OR ( Built –in OT )

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR Digital-OR Integrated-OR Hybrid-OR Robotic-OR Modular-OR