Systems Design Review : Heart Pump and Circulatory System

Slides:



Advertisements
Similar presentations
CARDIAC OUTPUT DR. EMAN EL ETER PHYSIOLOGY DEP. Definitions Cardiac output (CO): Amount of blood pumped by each ventricle per minute. Stroke volume (SV):
Advertisements

AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew.
Data Acquisition Risanuri Hidayat.
Mike Allocco, Soham Chakraborty, Leslie Havens, Danielle Koch, Andrew Miller, Kristeen Yee, Stephanie Zambito TEAM 14026: SUBSYSTEM DESIGN REVIEW P14026_Subsystem.
LVAD is a battery-operated, mechanical pump-type device that's surgically implanted. Goal of LVAD: providing the patient with as close to a normal lifestyle.
P08026: Modular Hemodynamic Flow Simulator Jason Brown Mechanical Engineering Amanda Clark Mechanical Engineering Matthew Hicks Electrical Engineering.
1. P09203 – 1kg Robotic Motor Module Gen 2 Platform This project is Sponsored by the Kate Gleason Foundation.  Team Members:  Lauren Farnsworth → Team.
MSD-I Project Review Modular Motion Tracking Sensors 1.
Multidisciplinary Engineering Senior Design Project 6508 Controls Lab Interface Improvement Preliminary Design Review 11/11/05 Team Members: Michael Abbott,
Bradley University Department of Electrical and Computer Engineering 2011 Wind Tunnel Control (WEBWIND) By: Adam Green Advisor: Dr. Aleksander Malinowski.
Space Engineering Institute (SEI) Space Engineering Research Center Texas Engineering Experiment Station, Texas A&M University Integrated Thermal Energy.
Chapter: 38 Pulmonary Circulation, Pulmonary Edema, Pleural Fluid
Introduction to Computer Technology
“HEAR IT AND FORGET IT, SEE IT AND REMEMBER IT, DO IT AND UNDERSTAND IT” R12310: ME and ChemE Lab and Demo Hardware Development DPM – Spring 2012.
Critical Design Review Wind Turbine with Gearbox
Jon KleinISEProject Manager Nguyen VuMETechnical Lead Kyle MengesMETechnical Lead Christine LowryMEDesign Engineer Chris SteinMEDesign Engineer Priya NarasimhanEEElectrical.
System Design Review April 5th, 2013 P13623: Conductive Heat Transfer Lab Equipment.
Mike Allocco, Soham Chakraborty, Leslie Havens, Danielle Koch, Andrew Miller, Kristeen Yee, Stephanie Zambito TEAM 14026: SYSTEM DESIGN REVIEW P14026_System.
P12022: LVAD P OWER T RANSMISSION T EST R IG Erin McNally Pedro Baez Paul Parthemore Kris Stichter.
Preliminary Detailed Design Review P15080 Flow Culture System November 13, 2014.
P16221 – FSAE Shock Dynamometer System Level Design Review September 29, 2015.
ERC C&E Fluid Power 1 ROTARY SELF-SPINNING HIGH SPEED ON-OFF VALVE Center for Compact and Efficient Fluid Power Department of Mechanical Engineering University.
Background Most modern car engines are 4 stroke engines. To achieve maximum efficiency. the engine must be supplied with precise fuel amounts.
Senior Design Project Update 1/29/14 Jake Bumpus, Casey Fitzgerald, and Michael Schultis.
P15080: Flow Culture System Multi-Disciplinary Senior Design Problem Definition Review September 11, 2014 Collin Burkhart – Lead Mechanical Engineer Katelyn.
P16453 Subsystem Design Loading, Measurement, Control, and Test of a Journal Bearing Test Platform Kris Kidder | John Dolan | Shay Stanistreet | Anthony.
P16081: SYSTEMIC CIRCULATION MODEL Jacob Zaremski – Lead Engineer Mallory Lennon – Project Manager John Ray – Communications Manager Fabian Perez – Purchasing.
Nanofluidic Characterization David Sharp David West Justin Davis.
E-NABLE Hand Test Rig P16061 David Schwartz, Tia Parks, Shannon Barry, Samantha Mason, Charles Rumfola.
P16452: Active Reciprocating Compressor Valve Assembly Week 9: Subsystem Design Review.
SYSTEM LEVEL DESIGN REVIEW P16318 Gaseous Mass Flow Rate Controller Luke McKean, Lianna Dicke, Selden Porter, Schuyler Witschi ?
Motor Assisted Wheelchair Design Review 10/01/15.
Mass Flow Sensor Integration Team 5: Beau Rodgers Luis Mendez Brian Roberts Keenan Cheeks Sponsored by: Danfoss Turbocor Advised by: Dr. Shih.
Date of download: 6/7/2016 Copyright © ASME. All rights reserved. From: Mock Circulatory Loop Compliance Chamber Employing a Novel Real-Time Control Process.
Allen Luccitti (ME). Mission Statement Product Description ▫ Test stand consisting of a centrifugal pump, closed loop flow system with control through.
P16452 Active Reciprocating Compressor Valve Assembly System Review.
Six Sigma Greenbelt Training
Turbomachinery Flow Visualization P08453
Pacemaker II Lecture (6).
Date of download: 11/15/2017 Copyright © ASME. All rights reserved.
P13623: Conductive Heat Transfer Lab Equipment
Project Members: M.Premraj ( ) G.Rakesh ( ) J.Rameshwaran ( )
P17082 Biomechanical Elbow Model Preliminary Detailed Design
P17082 Biomechanical Elbow Model Detailed Design
HEMODYNAMIC SIMULATOR II P09026
Product Evaluation & Quality Improvement
HEMODYNAMIC SIMULATOR II P09026
Kris Kidder | John Dolan | Shay Stanistreet | Anthony Miuccio
Product Evaluation & Quality Improvement
Heart Pump and Circulatory System
P15661 Reciprocating Friction Tester Base Subsystem
Nanofluidic Characterization
P17452 Dresser-Rand System Health Monitor System Level Design Review
P17082 Biomechanical Elbow Model Build and Test Prep
Data Acquisition (DAQ)
CONTROL SYSTEM AN INTRODUCTION.
Heart Pump and the Circulatory System P17080
Final Project Review -Senior Design 2
Critical Design Review
P15611: Digital Microfluidics Packaging
Mechanical Bioreactor
Simulated Assembly Line and Processing Workstation
Systems Level Design Review
Lecture 13 Teamwork Bryan Burlingame 1 May 2019.
Solar Generation System
Detailed Design Presentation
P18044 – Tremor Mitigation Device 2
Detailed Design Review: P18001
P19045 Essential Tremor Test Rig II Final Review April 7th, 2019
Preliminary Detailed Design Review: P18001
Presentation transcript:

Systems Design Review : Heart Pump and Circulatory System Susan Rhodes, Kevan Bjornson, Blake Suhr, Michael Kromos, Henry Davignon

Agenda Review Problem Definition Requirements Concept Development Functional Decomposition Benchmarking Morph Chart Feasibility Concept Selection Pugh Analysis System Architecture Updated Risks Plans for Next Phase

Project Objective Improve and integrate the current heart pump and circulatory system models. The finished model must be acceptable for a laboratory setting and be accompanied by a user friendly LabVIEW interface. The finished model must demonstrate desired physiological conditions.

Customer Requirements

House of Quality

Concept Development Functional Decomposition Benchmarking Morph Chart Feasibility

Benchmarking (System model)

Benchmarking (Resistance)

Benchmarking (Tubing)

Morph Chart

Ventricle Feasibility most compatible with current system only relative shape accuracy desired 3D printed mold Cost effective relative to piston 3 molds for 30$ with remaining silicone Physiologically accurate

Piston Heart Pump Feasibility -The Heart Pump as it currently sits is a Piston design with a spring loaded plate in a diaphragm. Updating this system would only require minimal changes in design with only a few updates to current parts. The resulting cost is therefore minimal and the system would perform more reliably. -The current design was not physiologically accurate – while it came close, there were some issues with the data being collected. After speaking with Dr. Day, he believes that this type of system does not accurately model the pre-load phase, which would throw off the data slightly. This is due to the spring system which is creating a negative pressure, almost a suction, thus pulling the fluid into the chamber – which is not what we want

Feasibility of Solenoid Use Problem: The current solenoid has a maximum switching frequency and the customer requirements state that the pump must operate at 2.5 Hz. Solenoid was tested by firing relay with an Arduino controller Speed was slowly increased until solenoid was unable to return to closed position Upper limit frequency was calculated by counting number of fires in a ten second period. Upper frequency tapers at 2.8Hz and solenoid fails at 3Hz Conclusion: It is feasible to use the current solenoid to operate the pump efficiently from 2.5-2.8HZ

Feasibility of DAQ Use Problem: There are two types of DAQs available from the BME department for use. Is it feasible to operate the loop using one DAQ? DAQ # of Ai channels # of Ao channels # of D io channels Max input rate myDAQ 2 7 200 kS/s USB-6211 16 4 400 kS/s Device/Sensor Channel Required Relay Analog out Air Regulator Pressure sensor(x2) Analog in Flow sensor(2) Conclusion: Our proposed design will require the use of 2 analog out channels and 4 analog in channels. Therefore, it is feasible for us to operate using one NI USB-6211 DAQ.

Concept Selection Pugh Analysis System Architecture Updated Risks

Pugh Chart

System Architecture

Proposed Lab Exercise 1 (PV loop Observation) Uses real clinical diagnostic techniques learned in coursework Students would observe the impact predetermined simulations have on real-time visual data Pressure volume (PV) loops would be displayed in triplicate to allow for comparison. Required hardware: Pressure sensors, flow-sensor

Proposed Lab Exercise 2 (Starling Curve Plots) Students would collect discrete data points using the labveiw program Small adjustments would be made to the loop to reach required points Data would be exported an analyzed for lab report Requires the use calculation of ventricular volume, cardiac output, right atrial pressure, and flow) Achieved by use of flow and pressure sensors

Updated Risk Assessment

Updated Plans: Silicone Ventricle The idea for the ventricle design started in an SME interview with Dr. Day. The current model was based on a piston and raised some concerns to the biological accuracy of such a model. He presented his heart model loops and the ventricle design appeared to be the most compatible with the current system. Using CAD a draft of a ventricle design was created and brought to Mike Buffalin at the construct. Mike had made the previous molds for Dr. Day’s and Dr. Mix’s loops. The mold is currently in the process of being 3D printed. The ventricle will be made by pouring silicone into the mold. The ventricle has a volume of 120ml. The silicone mix is estimated to cost $30 per pint. Which would provide enough for 3 molds with almost enough for an additional mold remaining. The calculations show the ventricle is approximately $10 per mold, where the diaphragm was $50 per unit. One extra plate is needed to hold the ventricle in place, at a cost of $10. There are very few risks and enough reward to justify a prototype for further testing

Next Steps The major change is a shift of focus from repair to remake. From our previous steps, we determined that many of the systems were either too broken or technologically insufficient to warrant fixing

Team Action Items Create and assemble the ventricle prototype Test the pump against the Engineering Requirements Decide if the ventricle pump should continue to be perused. Identify all material in the circulatory system that needs to be replaced. Test various tubing for compliance and identify the desired tubing Generate preliminary LabVIEW program