Deyuan Kong, Brian Morlan, Roopa Kamath, and Sara Mcmillen

Slides:



Advertisements
Similar presentations
Radiochemical Methods and Data Evaluation
Advertisements

Gas Chromatography 427 PHC.
Lecture 8b Gas Chromatography.
The Foundations: Classical Split and Splitless Injection
InfraCal TOG/TPH Analyzers for Oil and Grease Measurements
Simple, Fast and Accurate Solvent-free Method for Produced Water Process Monitoring.
SESSION: MANAGING CONTAMINATION North Carolina DOT’s Experience with UV Fluorescence for Measuring Petroleum Contamination in Soil Cyrus Parker, LG P.E.,
Analysis of Residues. Laboratory Analysis of Debris and Other Samples 1. Preparation of Liquid Samples: Liquid samples are simply drawn into a special.
Gas Chromatography in the detection of Volatile Organic Compounds.
I n t e g r i t y - S e r v i c e - E x c e l l e n c e Headquarters U.S. Air Force 1 Direct Sampling Ion Trap Mass Spectrometry Rob R. Smith Oak Ridge.
Laboratory Tests for Petroleum Pre ME tests: TPH by EPA SW s Gasoline and Fuel Oil: DEP and Gasoline and Fuel Oil: DEP.
Mass Spectrometry Inlet system Ion Source Mass Analyzer Ion Detector.
.
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Partitioning of Volatile Organic Carbon Compoundss.
Methods Monitoring Polar Compounds Using Membrane Extraction and High-Speed Gas Chromatography Authors: Jonathan Maurer, Dr. Anthony J. Borgerding* Department.
.
Monitoring the desorption of analytes from nonpolar SPME fibers using high speed gas chromatography Authors: Kimberly Jasch, Tony Borgerding* Department.
Partitioning of VOCs: Why do we care? ä Determines how best to treat a site ä vapor extraction ä pump and treat ä remove contaminated soil ä Determines.
Instant Notes Analytical Chemistry
DRAFT Field Sampling Guidance To be used this field season by DEC and consultants Initial focus on soil, groundwater, and vapor intrusion Future versions.
US Army Engineer Research & Development Center One Team, One ERDC... Relevant, Ready, Responsive, Reliable Field Portable GC-MS Instrument for Analysis.
Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Monitoring Well Sampling. SAP (Sampling Analysis Plan) SAP (Sampling Analysis Plan) Frequency Frequency Purging Purging Pumps and Bailers Pumps and Bailers.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Industrial Air Quality Monitoring. Sampling Protocols Grab vs. Integrated Personal vs. Area.
ASTM WK Standard Test Method for Dissolved Gases Anne Jurek – Applications Chemist.
 Introduction  Theory  Advantages/Disadvantages  Applications  Conclusions.
Copyright 2008 © Silliker, All Rights Reserved Collection of Samples for Chemical Analysis.
William Kou Jonathan Mertz. Introduction The field of Mass Spectrometry using Ambient Ionization techniques has grown exponentially since The direct.
A New Risk-Based Approach to Establish Clean-up Levels for TPH David Nakles and Stephen Geiger ThermoRetec Consulting and Engineering Sara McMillen and.
Overbrook Scientific.
HP Labs Escondido, CA Methanol and Ethanol Analysis/ J. Picker The Ultimate Gourmet Martini.
Development of a headspace solid-phase microextraction method coupled to gas chromatography (HS-SPME GC-MS) to capture and analyze the volatile organic.
Application of solid-phase microextraction to the recovery of explosives and ignitable liquid residues from forensic specimens K.G. Furton, J.R. Almirall,
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
Analytical Separations
Chapter 29 Supercritical Fluid Chromatography and Extraction.
High Resolution Site Characterization of 1,4 Dioxane Sites using a New On-site, Real-time Analysis William M. Davis, Christopher P. Antworth and Christopher.
Micro Analytical GC System for Tea Aroma in Product Quality Control Fred Lewis, Principal Chemist, Analytical Science Laboratory, Unilever John Crandall,
Providing comprehensive scientific resources to environmental clients worldwide. Dissolved Gas Analysis: A Review and Comparison.
Phil Smith, PhD, CIH USDOL-OSHA Health Response Team Sandy, Utah Field-Portable GC-MS for Human Exposure Assessment.
High Resolution Site Characterization Approach: Rapid Sample Collection with High Quality Analyses Targeting VOCs/SVOCs Presented by: Harry O’Neill, President.
Introduction to Gas Chromatography
Chapter 1: The Nature of Analytical Chemistry
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
Introduction The pyrolysis products of natural polymers often exhibit very similar neural losses during collision induced dissociation (CID) Some ions.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Bioseparation II Chromatography Techniques. Chromatography Most widely used purification technique used for biomolecules. Most widely used purification.
Determination of Algae Compounds in Drinking Water
Marine Science Institute, The University of Texas at Austin
EPA Method Equivalency
Update on Improvements to Dissolved Hydrocarbon Gases in Water Analysis Mark Bruce Ph. D. August 10, 2017.
Evaluation and Application of SPME Arrows
Improved Accuracy of Dissolved Hydrocarbon Gas Analysis in Water
Gas Chromatography.
Supercritical Fluid Chromatography and Extraction
EPA Method Equivalency
CLEANING VALIDATION FOOD & BEVERAGE –– WASTEWATER –– LABORATORY –– PHARMACEUTICAL & MEDICAL DEVICE.
Deyuan Kong and Sara Mcmillen, Chevron Energy Technology Company USA
Pure Carrier Gas Grades (subjective)
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Effective Measurement and Monitoring of Total Petroleum Hydrocarbons with Field Equipment Patrick Tyczynski M-I SWACO, a Schlumberger company.
VAPOUR PHASE CHROMATOGRAPHY
Gas Chromatography.
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
GAS CHROMATOGRAPHY.
EPA/OAQPS Pollutant Emissions Measurement Update 2019
Presentation transcript:

Field Analytical Method Development for C6-C9 Range Hydrocarbon Measurement Deyuan Kong, Brian Morlan, Roopa Kamath, and Sara Mcmillen Chevron Energy Technology Company USA Deni Hendrawati, Hatta Muhammad, Kasman Sutrisno, Tri Wisono, and Timothy Vidra PT. Chevron Pacific Indonesia

Project Background and Objective Data gap was identified during 2016 delineation work plan approval process. Develop simple field screening method for C6–C9 petroleum hydrocarbon (PH) in soil using portable GC-MS and headspace sampling. Demonstrate detection limit of C6–C9 PH of 50 ppm or below. Meet regulatory requirement for soil segregation and remediation. Secondary objective is to measure the benzene concentration in soil samples.

Torion T-9 Portable GC-MS Portable instrument for field use. Rapid sample analysis. Fast chromatography using LTM-GC. Low thermal mass (LTM) gas chromatography (GC). Short metal capillary column. Cycle time of less than 5 minutes. Miniature and high sensitivity mass spectrometer for identification of compounds. Toroidal ion trap mass spectrometry. Ions trapped and ejected by radio frequency, yielding m/z values.

Sample Injection Solid Phase Microextraction (SPME) syringe. 19 gauge needle. 1 cm fiber coated with DVB/PDMS polymer. Vapor phase molecules adsorb to the fiber. Molecules compete for fiber locations based on DVB & PDMS affinity.

Field Sampling and Testing Protocol 5 grams of TPH contaminated soil in a 20 mL VOA vial with a septum cap. SPME syringe to collect headspace. Agitate soil in VOA vial to liberate C6- C9 range molecules. 1 minute sampling of headspace. ~ 1 cm above soil. Inject SPME syringe into T-9 GC-MS. External calibration with crude oil with known C6-C9 and benzene content. ~0.02 g crude oil in 5 g blank soil.

T-9 External Calibration by ASTM D7900 The data quality objective is to measure C6-C9 in soil originating from crude oil. Unlike GC-FID, GC-MS has significantly different response factors for compounds. Crude oil contains over 100 hydrocarbon compounds in the C6-C9 range. Certified GRO standards are typically composed of gasoline type material. Gasoline has a different hydrocarbon composition compared to crude oil. A crude oil has been used as the calibration standard with no solvent present. Typical solvents interfere with the T-9 analysis of the C6-C9 range. ASTM D7900 by GC-FID is the preferred method for measuring C2 to C9 compounds in stabilized crude oil. Internal lab certified the crude oil standard to be C6-C9 = 15.97 weight % and Benzene = 0.36 weight %. Gasoline is not representative of crude oil.

Method Verification Crude oil with ASTM D7900 certified C6-C9 content and certified blank soil. Prepared soil samples with varying amounts of crude oil. Samples split for comparison with a 3rd party lab. Chevron lab T-9 GC-MS 3rd party lab EPA Method 8015B (GC-FID). Duplicate injections were performed on the T-9.

Method Bias Evaluation Measure the method bias with field sample tested by a conventional lab method. Soil samples collected at a former oil field and shipped to Chevron lab. Samples split in the lab for comparison with a 3rd party lab. Chevron lab T-9 GC-MS 3rd party lab EPA Method 8015B (GC-FID). T-9 results are higher for the field samples compared to the 3rd party results. Heterogeneity of the samples may have caused the discrepancy. Different analytical methods. Different calibration standard. Same lab and method as the method verification

Impact of Soil Moisture Content Crude oil with ASTM D7900 certified C6-C9 and Benzene content. Certified blank soil. Vials spiked with varying amounts of deionized water by weight. Shake the vials vigorously to mix the soil, crude oil, and water. All of the vials containing water had some soil adhering to the vial wall. The 30% water vial had a significant amount of soil adhering to the vial wall and did not mix well. Soil adhering to the side of the vial may be providing more surface area for liberation of C6-C9 components to the vapor phase.

Portable GC-MS Field Pilot Results 253 freshly collected soil samples over the course of 10 days from a crude oil production field. 166 soils contained variable concentration levels of TPH, as reported by EPA Method 8015C.

TIC – Calibration Standard C6 Starts C9 Ends Crude Oil Calibration Standard Certified by ASTM D7900 C6-C9 = 276 ppmw

TIC – Sample Containing C6-C9 >= 100 ppmw C6 Starts C9 Ends C6-C9 = 112 ppmw

TIC – Sample Containing C6-C9 >= 100 ppmw C6 Starts C9 Ends Red = Calibration Standard 276 ppmw C6-C9 Blue = Sample 112 ppmw C6-C9

TIC – No C6-C9 Present C6 Starts C9 Ends

Field Pilot Comparison with 8260B 3rd party lab performed EPA Method 8260B with a Purge and Trap (PT) device and soil samples were prepared using modified EPA Method 5035. Possible reasons for data variation. VOC loss due to sample handling in a hot humid field. Sample introduction techniques- Headspace Injection vs. PT Calibration Sampling issue? Sample integrity? ND = Below detection limit 40 ppm

Soil Appearance C6-C9 = 80 ppmw C6-C9 not detected These soils were mostly like tar or sticky. Samples can look similar but contain significantly different C6-C9 ranged material.

Summary This portable GC-MS instrument will enable rapid C6-C9 screening data collection in the field. Significant time reductions for labs relying on third party data. Real-time process monitoring. Rapid, field-based testing. Easy to operate. Improved safety by elimination of solvents. Prevents worker exposure. Eliminates generation of waste. Potential Cost Savings.