Telephone & Exchange Tester ETET 30

Slides:



Advertisements
Similar presentations
Presented by: Eng. Karam Al-sofy
Advertisements

Telecommunications & Networking
1 Telephone Connection. 2 Introduction The section instructs you on how to install a required phone line to every receiver.
Application Notes for Line Testing with ET 91 To learn more click on note! Single Sided Measurements END to END Measurements LCL Balance Impedance Return.
To learn more click on the selected method! Typical Cable Faults Unbalance Recommended Fault Location Method Disturbing voltage ▼ Murray ▼ Küpmüller ▼
Principles of Voice & Data Lesson 4: Troubleshooting Bellevue Community College Bob Young, Instructor.
BASIC TELECOMMUNICATIONS
Automatic xDSL Test Sequences of ELQ 30A
Application Notes for Frequency Division Multiplex System Testing with ET 91 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise.
Automatic Single Sided Test Sequence of ELQ 30A To learn more click on the selected topic! ELQ 30A provides single sided test sequences to estimate the.
The Telephone Instrument
Chapter 1: Computer Networks IB 300: Advanced Computer Sciences. Professor: Nabil Elmjati.
The Telephone and Telephone Line Chapter 2 Overview of a Telephone System Telephone set’s major parts Transmitter Converting sound wave to electrical.
Chapter 9 Using Telephone and Cable Networks for Data Transmission Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or.
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
Ethernet and Wifi Chapter 7 & 8. Send and Receive Data network adapter or network interface NIC card the most common wired Ethernet network interfaces.
Training PowerPoint.  Just plug into the USB port on your computer. You will find USB ports on the front or back of your computer.  If you have a laptop.
DSL-2544N Dual Band Wireless N600 Gigabit ADSL2+ Modem Router
Communication Markets Division © 3M All Rights Reserved. 965AMS Product Overview.
GS3055-I Installation Process
Telecommunication II.
©UNT in partnership with TEA1 Telecommunications & Networking Unit Subtitle: Modems.
Communication Markets Division © 3M All Rights Reserved. 965AMS Autotest Training.
Single Ended Line Test with Upgraded ECFL 30
XDSL Line Tester Modem EX 30M ELEKTR NIKA EX 30M is a handheld, cost-effective test set to check DSL services and the copper cable capability. It is a.
Frequency Division Multiplex System Testing with ET 92 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise END to END Measurements.
Manual Measuring Modes of ELA 10 To learn more click on the selected topic! Level, Loss Noise, Spectrum Line Parameter Optional Measurements Transmitting.
«Alfa-Avto: Mobile advisor»
MTA Network Fundamental Cram Sesion
Single Ended Measuring Modes of ELQ 30A+
DS200 EEPROM PROGRAMMING.
Configure the intercom IP
Circuit Switching and Telephone Network
DS200 IDEA LINE PARAMETERS
The Internet Networks This icon indicates the slide contains activities created in Flash. These activities are not editable. For more detailed instructions,
The Internet Networks This icon indicates the slide contains activities created in Flash. These activities are not editable. For more detailed instructions,
Automatic xDSL Test Sequences of ELQ 30A+
Connecting to the Internet
Installing the HP LaserJet Pro 500 color MFP M570 printer software in Windows on a Wireless Network & Wired Network.
Setup Of 4050 EIP To Control LOGIX PLC
The Hong Kong University of Science and Technology
Single Ended Line Test with Upgraded ECFL 30
Lecture 5: TELEPHONE NETWORK
xDSL Line Tester Modem EX 30M
Telephone & Exchange Tester ETET 30
Automatic Voice Frequency Test Sequences of ELQ 30A+
Inovonics Wireless Corporation
Chapter 9. High-Speed Digital Access: DSL, Cable Modems
Which one is the Proper Fault Location Method ?
Which one is the Proper Fault Location Method ?
xDSL Line Tester Modem EX 30M
Single Ended Line Test with Upgraded ECFL 30
xDSL Line Tester Modem EX 30M
Digital Chart Recorder Operation
Automatic Single Sided Test Sequence of ELQ 30A+
Cisco 7925 Phonebook Userguide
DSCI’s UCx Hosted Telecommunications Service
Manual Measuring Modes of ELA 10
Manual Measuring Modes of ELA 10
Chapter 3 Analog Cellular Communications AMPS System
Follow the Data Data (and information) move from place to place in computer systems and networks. As it moves it changes form frequently. This story.
Automatic Test Sequences in Master-Slave Mode
Lecture 5: TELEPHONE NETWORK.
Objectives of Today’s Lecture
Automatic Test Sequences in Master-Slave Mode
Objectives of Today’s Lecture
Lecture 3: TELEPHONE NETWORK.
User Training for Polycom VVX desksets
User Training for Yealink T4 desksets
Presentation transcript:

Telephone & Exchange Tester ETET 30 ELEKTR NIKA ETET 30 is a central office installed touch screen controlled instrument intended to identify the cause of subscriber complaints. The operator can test: ● The circuits of exchange ● The operation of DSLAM ● The parameters of line ● The subscriber’s phone set ● The noise spectrum Test groups: ● User Side Tests ● Exchange Side Tests ● Modem Detection ● ADSL Test ● VDSL Test For details click on the corresponding keys.

User Side Tests of ETET 30 ELEKTR NIKA The user side tests are intended: ● To test the access line when the subscriber’s phone is in on-hook state. ● To test the subscriber’s phone set with his assistance. Selectable Modes: ● DMM ● TDR ● Spectrum analyser ● Test Call For details click on the corresponding keys.

User Side DMM Measurements ELEKTR NIKA Voltage Measurements ● AC, DC voltages between wire A and GND ● AC, DC voltages between wire B and GND ● AC, DC voltages between wires A and B Insulation Resistance Measurements ● Between wire A and GND (RAE) ● Between wire B and GND (RBE) ● Between wires A and B (RISO) with normal and reversal polarity Capacitance Measurements ● Between wire A and GND (CAE ) ● Between wire B and GND (CBE ) ● 2 Pole capacitance between the wires ● Load capacitance CL Automatic Test Sequence ● Pressing the Auto key ETET 30 performs the previous measurements. Continuity Measurement ● In this mode ETET 30 performs loop resistance measurement. If the loop resistance lower than a preset threshold acoustic warning is provided. Test results exceeding the designated limits are marked with red color.

Two modes are provided: User Side TDR ELEKTR NIKA In case of a cable break or short circuit the first task is to identify the location of fault. First of all the operator has to know that the fault is inside the building of central office or it is somewhere else on the line. The purpose of the User Side TDR is to test the access line. Two modes are provided: ● Normal mode for the localization of shorts and brakes. ● Long time mode for the localization of loose contacts.

Spectrum Analyser ELEKTR NIKA The purpose of the User Side Spectrum measurement is to get information about the disturbing voltages on the line. In that mode ETET 30 can detect the presence of ADSL, ADSL 2+ or VDSL modem at the user’s home when the DSLAM is disconnected from the subscriber’s line.

User Side Test Call ELEKTR NIKA In this mode the subscriber’s telephone set can be tested with his assistance. The operator should call and communicate with the subscriber. Loop Test Ask the subscriber to keep the line and wait. Start loop resistance and loop current measurements with the Loop Test key. Loudness Test Send test tone with the Send 800 Hz key. After a while ask the subscriber’s opinion about the loudness. Dial Test Sometimes the subscribers complain that they are connected to another subscriber instead of the one they wanted to call. The purpose of that test is to identify the reason of the malfunction. Press the Dial Test key. Ask the subscriber to press the numbers on his key board after each other.

Exchange Side Tests of ETET 30 ELEKTR NIKA ETET 30 provides: ● The test of ringing, register and line feed circuits of exchange. ● The location of wiring problems inside the building of central office. Selectable Modes: ● DMM ● TDR ● Ringing Test ● Register Test For details click on the corresponding keys.

Exchange Side DMM Measurement ELEKTR NIKA Voltage Measurements ● AC, DC voltages between wire A and GND ● AC, DC voltages between wire B and GND ● AC, DC voltages between the wires Loop Current Measurements ● When the loop is closed. Automatic Test Sequence ● Pressing the Auto key ETET 30 performs the previous measurements. Continuity Measurement ● In this mode ETET 30 performs loop resistance measurement. If the loop resistance lower than a preset threshold acoustic warning is provided. Test results exceeding the designated limits are marked with red color.

Two modes are provided: Exchange Side TDR ELEKTR NIKA In case of a cable break or short circuit the first task is to identify the location of fault. First of all the operator has to know that the fault is inside the building of central office or it is somewhere else on the line. The purpose of Exchange Side TDR is to test the wiring inside the building of central office. Two modes are provided: ● Normal mode for the localization of shorts and brakes. ● Long time mode for the localization of loose contacts.

Ringing Test ELEKTR NIKA In this mode the operator can dial up any phone number using a service line. Typical applications: ● The subscriber complains that the loudness of ringing is not enough. To check the proper operation of exchange the operator dials the user’s phone number and ETET 30 measures the ringing voltage. ● The operator would like to use ETET 30 as a normal phone.

Register Test ELEKTR NIKA Sometimes the subscribers complain that they are connected to another subscriber instead of the one they wanted to call. The purpose of that test is to identify the reason of the malfunction. In this mode ETET 30 sends a test call from the subscriber’s line to the service line and indicates the appearance of ringing voltage.

Modem Detection ELEKTR NIKA Function: In that mode ETET 30 can detect the presence of ADSL, ADSL 2+ or VDSL modem at the user’s home when the DSLAM is disconnected from the subscriber’s line. Principle of operation: The modem detection is based on spectrum measurement. ETET 30 recognizes the hand shake signals rhythmically transmitted by the modem.

ADSL Modem Tests ELEKTR NIKA By means of the “Golden Modem” of ETET 30 we can check the proper operation of DSLAM. ETET 30 offers two test options: ● Synchronization Test providing information on the training process and the actual state of line. In this mode there isn’t data transfer between the local and public network. ● Automatic Test providing detailed information on the quality of data transfer between the local and public network. The actual connection profile and the LAN parameters can be modified before starting the test. For details click on the corresponding keys.

ADSL Synchronization Test ELEKTR NIKA When the synchronization test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. The status indicator shows the actual state of synchronization: RED The line is in Idle State (No synchrony) GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization is completed Finishing the training process ETET 30 provides detailed line diagnosis.

For details click on the corresponding key. ELEKTR NIKA Automatic ADSL Test When the automatic test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. xDSL connection Indicator RED No synchrony GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization is completed Link IP Status Indicator There is no data transfer YELLOW Trying to establish data transfer GREEN Successful data transfer ETET 30 provides: ● Ping & Trace test ● Detailed line diagnosis ● Browsing possibility For details click on the corresponding key.

Editing of ADSL Profile ELEKTR NIKA ETET 30 supports the synchronization in all ADSL modes and connection types. Supported ADSL Modes As a default ETET 30 supports the synchronization in all ADSL modes but the operator can disable one ore more of them. Selectable connection types: In ADSL mode ETET 30 supports five connection types.

LAN Settings ELEKTR NIKA The IP parameters of the modem and the controller PC can be modified here.

To call the Trace Test window click on the Trace key Ping & Trace Test ELEKTR NIKA The ping tests can manage: ● the URL format ● IP address format The number of PING requests and the size of PING packets can be set. To call the Trace Test window click on the Trace key

Trace Test ELEKTR NIKA The Trace Test can manage: ● the URL format ● IP address format

Line Diagnosis ELEKTR NIKA In this mode ETET 30 provides detailed line diagnosis in graphic and numeric forms.

VDSL Modem Test ELEKTR NIKA By means of the “Golden Modem” of ETET 30 we can check the proper operation of DSLAM. ETET 30 offers two test options: ● Synchronization Test providing information on the training process and the actual state of line. In this mode there isn’t data transfer between the local and public network. ● Automatic Test providing detailed information on the quality of data transfer between the local and public network. The actual connection profile and the LAN parameters can be modified before starting the test. For details click on the corresponding keys.

VDSL Synchronization Test ELEKTR NIKA When the synchronization test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. The status indicator shows the actual state of synchronization: RED The line is in Idle State (No synchrony) GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization is completed Finishing the training process ETET 30 provides detailed line diagnosis.

For details click on the corresponding key. ELEKTR NIKA Automatic VDSL Test When the automatic test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. xDSL connection Indicator RED No synchrony GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization is completed Link IP Status Indicator There is no data transfer YELLOW Trying to establish data transfer GREEN Successful data transfer ETET 30 provides: ● Ping & Trace test ● Detailed line diagnosis ● Browsing possibility For details click on the corresponding key.

Editing of VDSL Profile ELEKTR NIKA ETET 30 supports the synchronization in all VDSL modes and connection types. Supported ADSL Modes As a default ETET 30 supports the synchronization in all VDSL modes but the operator can disable one ore more of them. Selectable connection types: In VDSL mode ETET 30 supports three connection types.

LAN Settings ELEKTR NIKA The IP parameters of the modem and the controller PC can be modified here.

To call the Trace Test window click on the Trace key ELEKTR NIKA Ping &Trace Test The ping tests can manage: ● the URL format ● IP address format The number of PING requests and the size of PING packets can be set. To call the Trace Test window click on the Trace key

Trace Test ELEKTR NIKA The Trace Test can manage: ● the URL format ● IP address format

Line Diagnosis ELEKTR NIKA In this mode ETET 30 provides detailed line diagnosis in graphic and numeric forms.