Components of Substation

Slides:



Advertisements
Similar presentations
Introduction to Switchgear
Advertisements

Electrical Installation
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
SUBSTATION HIGH VOLTAGE COMPONENTS
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Substations. Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose,
ABS Ennin, George Coleman, David Dadson & Anthony Ansah
Unit-3 SUBSTATIONS.
ELECTRICAL SAFETY Part 1: Basic Electricity k groves /e haller.
Electrical Power Systems
What makes substation work?
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
Transformer Taking the ratio of the two equations
POWER HOUSE.
What is POWERGRID??? The Power Grid Corporation of India Limited (POWERGRID), is an Indian state-owned electric utilities company headquartered in Gurgaon,
Submitted to: Submitted by:
Introduction to switchgears
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
A Presentation On 132 KV GSS BEHROR
Submitted to: Submitted by:
SUBSTATION LAYOUT AND ACCESSORIES
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
Simple Circuits & the Transfer of Electrical Energy
Distribution Systems-General
ON 400 KV GSS RAISER JAIPUR ROAD ,BIKANER
A Training Presentation On 132 KV GSS JAIPUR Submitted in partial fulfillment For the award of the degree of BACHELOR OF TECHNOLOGY Submitted To:- Submitted.
220 KV GRID SUB STATION MORAK,KOTA SUBMITTED TO:- SUBMITTED BY:- SHRI VIKAS BHALLA LAKHAN SINGH ASSISTENT PROFESSOR ROLL NO.-12ECTEE029 ELECRTICAL DEPARTMENT.
132KV GSS PIPAR CITY JODHPUR
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
A PRESENTATION On 400KV GSS SURPURA JODHPUR
Craig T. Riesen Energy Workshop II 1 Electricity & Generation Basics of Electricity and Electrical Transmission Transmission Generation electrons.
What makes substation work?
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
ELECTRICAL INSTRUMENTS ( service and utilization )
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Instrument Transformer Electrical Measuring Instruments & Instrumentation 3rd SEMESTER ELECTRICAL ENGG.
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
6 Week industrial Training Presentation
SEMINAR PRESENTATIon ON C IRCUIT B REAKER DEPT. OF ELECTRICAL ENGG. JALPAIGURI GOVT. ENGG. COLLEGE PRESENTED BY Madhusudan Mahato Malay Ghosh.
Push Button Station and Relay
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
HNC/D Engineering Science
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
High Voltage Engineering
Sub Station.
SUB-STATIONS.
Chapter # 25 Sub-Stations risemark.pbworks.com.
Circuits and Circuit Elements
High Voltage Engineering
Basics of electrical engineering
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Circuit Breakers & Reclosers
Objective Define Common electrical terms.
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
OVER VOLTAGE The voltage waves having magnitude more than its normal value. In other words, sudden rise to an excessive or abnormal value It remains for.
Chapter 7 System Protection
Overview Key diagram of 220 KV Sub station, Ablowal Cables
ELECTRICAL POWER-II Electrical engineering sixth semester
EHV Transmission Equipments
EET 323 – Electrical System Design Lecture 4: Wiring Devices
EET 323 – Electrical System Design Lecture 9: Grounding
Protection against over voltages
Ahmed Kulab Moh. Abed Foaad Al-Habeel
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
23.2 Applications of Circuits
Substation Equipment's
DIPLOMA In ELECTRICAL ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING GOVERNMENT POLYTECHNIC COLLEGE, HANUMANGARH Sept A Training Presentation On.
Presentation transcript:

Components of Substation

SUBSTATION SUBSTATION - A station in the power transmission system at which electric power is transformed to a conveniently used form. The station may consist of transformers, switches, circuit breakers and other auxilliary equipment. Its main function is to receive energy transmitted at high voltage from the generating station, by either step-up or step-down the voltage to a value appropriate for local use and provide facilities for switching. Substations have some additional functions. Its provide points where safety devices may be installed to disconnect circuits or equipment in the event of trouble. Some substation, such as power plant switchyard are simply switching stations where different connections can be made between various transmission lines.

Typical Components of a Power Plant Substation (Switchyard) CONNECT A - Busbar B - Disconnector C - Circuit Breaker D - Current Transformer E - Voltage Transformer F - Earthing Switch G - Surge Arrestor CONNECT & DIS-CONNECT CONNECT, DIS-CONNECT & DETECT DETECT & TRANSFORM DETECT & TRANSFORM PROTECT & SAFETY PROTECT

A. BUSBAR BUSBAR (or bus, for short) – is a term we use for a main bar or conductor carrying an electric current to which many connection may be made. Buses are merely convenient means of connecting switches and other equipment into various arrangements. The usual arrangement of connections in most substations permit working on almost any piece of equipment without interruption to incoming or outgoing feeders. In the switchyard or substation, buses are open to the air. Aluminum or copper conductors supported on porcelain insulators, carry the electric energy from point to point.

Busbars (long heavy tube type)

B. DISCONNECTS DISCONNECT – is an easily removed piece of the actual conductor of a circuit. The purpose of disconnects is to isolate equipment. Disconnects are not used to interrupt circuits; they are no-load devices. A typical use of disconnects is to isolate a circuit breaker by installing one disconnect on either side of the circuit breaker (in series with the breaker). Operation of disconnects is one of the most important and responsible jobs of a power plant operator. One error in isolation of equipment, or the accidental grounding of line equipment, can be a fatal mistake.

( moving contact rod (A) & contacts with flexible fingers (B) ) Disconnect Switch ( moving contact rod (A) & contacts with flexible fingers (B) ) B A

C. CIRCUIT BREAKER CIRCUIT BREAKER – is used to interrupt circuits while current is flowing through them. The making and breaking of contacts in a Oil type circuit breaker are done under oil, this oil serves to quench the arc when the circuit is opened. The operation of the breaker is very rapid when opening. As with the transformer, the high voltage connections are made through bushings. Circuit breakers of this type are usually arranged for remote electrical control from a suitably located switchboard. Some recently developed circuit breakers have no oil, but put out the arc by a blast of compressed air; these are called air circuit breakers. Another type encloses the contacts in a vacuum or a gas (sulfur hexafluoride, SF6) which tends to self maintain the arc.

( Connected in a typical 3-phase circuit ) Operating Mechanism Panel Circuit Breakers ( Connected in a typical 3-phase circuit ) Position Indicator

D. CURRENT TRANSFORMER CURRENT TRANSFORMER – Current transformer are used with ammeters, watt meters, power-factor meters, watt-hour meters,compensators, protective and regulating relays and the trip coil of circuit breakers. One current transformer can be used to operate several instruments, provided that the combined burden does not exceed that for which the transformer is designed and compensated. The current transformer is connected directly in series with the line.

E. VOLTAGE TRANSFORMER VOLTAGE TRANSFORMER – also know as potential transformer, are used with volt-meters, wattmeters, watt-hour meters, power-factor meters, frequency meters, synchroscopes and synchronizing apparatus, protective and regulating relays and the no-voltage and over-voltage trip coils of automatic circuit breakers. One transformer can be used for a number of instruments at the same time if the total current taken by the instrument does not exceed that for which the transformer is designed and compensated. The ordinary voltage transformer is connected across the line, and the magnetic flux in the core depends upon the primary voltage

F. EARTHING SWITCH EARTHING SWITCH – also known as ground disconnect, which used to connects the equipment to a grid of electrical conductors buried in the earth on the station property. It is intended to protect people working on the grounded equipment. It does this by completing a circuit path, thereby reducing the voltage difference between the equipment and its surroundings. For safety reasons, it is important that ground disconnects and all associated connections have good contact and low resistance. It is also important that the protective ground not be accidentally remove, that is why all the earthing switches, disconnect switches and circuit breakers are all interlocked to each other and proper/correct sequencing must be followed.

G. SURGE ARRESTOR SURGE ARRESTOR – are devices used to provide the necessary path to ground for such surges, yet prevent any power current from following the surge. An ideal arrester must therefore have the following properties: 1. Ability to remove the surge energy from the line in a min. time. 2. High resistive to flow of power current. 3. A valve action automatically allowing surge to pass and then closing up so as not to permit power current to flow to ground. 4. Always ready to perform. 5. Performance such that no system disturbances are introduced by its operation. 6. Economically feasible

OVERHEAD GROUND WIRE – by a ground wire is meant a wire, generally of steel, supported from the top of transmission-line towers and solidly grounded at each tower. It is considered a preventive device, but it does not entirely prevent the formation of travelling waves on a line. Furthermore, those lines which are not equipped with ground wires will be subjected to disturbances which produce surges that must be allowed to escaped to ground, or the apparatus connected to the line must be strong enough to reflect or absorb these surges until they are entirely damped out.

PREVENTIVE MAINTENANCE BUSBARS & OVERHEAD GROUND WIRE At least once a year Visual Inspection & Examination of all wiring connectors. Check Insulator , clean or apply HVIC if necessary. Check the physical condition of bus (cables or bars) For ground wire, check or test the grounding system. DISCONNECT & EARTHING SWITCHES At least once a month Visual Inspection. Check heating resistor located at its control panel for proper functioning. Clean contacts of disconnectors as well as earthing switches and apply electrical contact grease , if necessary.

Check disconnectors and earthing switches, joints and bearings of the operating linkages for deformed bearing points. Check flexible connections of earthing switches. Check all screwed joints for tight fit. Clean insulators if necessary, when an excessive amount of dirt has accumulated. Carry-out the maintenance of operating mechanism. VOLTAGE TRANSFORMER At least once a month Inspect the voltage divider to be sure that no oil leak or serious accumulation of soot, dust or salt composite is present. Inspect the intermediate voltage transformer and check the minimum permissible oil level. At least once a year Check all screwed joints & contact for tight fit.

CURRENT TRANSFORMER SURGE ARRESTOR At least once a month Visual Inspection to check oil level and defects or possible oil leaks. At least once a year Check all screwed joints & contact for tight fit. Clean insulators if necessary, when an excessive amount of dirt has accumulated. Check primary and secondary connectors and conduct necessary tightening. Note: Never open a secondary winding of a CT while on service. SURGE ARRESTOR Visual Inspection & Examination of all wiring connectors. Check Insulator and metal circular ring, clean or apply HVIC if necessary. Check the physical condition of bus (cables or bars)

For ground wire, check or test the grounding system. Note: Arrestors should never be touched unless completely disconnected from all live lines and equipment and effectively connected to ground at the line side of the arrestor.

Thank You