Chapter 10: ANNUAL ENERGY ESTIMATION METHODS

Slides:



Advertisements
Similar presentations
eQuest Quick Energy Simulation Tool
Advertisements

New Construction Calibration Research Results and Request for Decision Regional Technical Forum March 18, 2014.
Environmental Controls I/IG
University of Liège Faculty of Applied Sciences Thermodynamics Laboratory Workshop “Commissioning and Auditing of Buildings and HVAC Systems” Use of a.
BPA Guidelines for Measurement & Verification of Energy Efficiency Measures Presented at Brown Bag Session November 29, 2006.
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
BEM class 3 Climate & Human Comfort. Class (lecture) objectives Appreciation of the indoor and outdoor environments and how they relate to our energy.
Energy Performance Analysis with RETScreen
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
Environmental Controls I/IG Lecture 12 Cooling Loads Cooling Degree Hours Energy Performance Ratings Annual Fuel Consumption Lecture 12 Cooling Loads Cooling.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
Energy Calculations Dr. Sam C M Hui
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Inference for regression - Simple linear regression
3 CHAPTER Cost Behavior 3-1.
Load Shifting and Peak Load Reduction using Building Thermal Mass
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Discussion of Mexican Adaptation of ENERGY STAR Methodology CEC Workshop Mexico City March 2013 Michael Zatz and Alexandra Sullivan ENERGY STAR Commercial.
M&V Part 2: Risk Assessment & Responsibility Allocation.
1 ISAT Module III: Building Energy Efficiency Topic 8: Thermal Performance Monitoring  Degree Days  Example of Degree days  Thermal Energy Consumption.
EvergreenEcon.com ESA 2011 Impact Evaluation Draft Report Public Workshop #2 August 7, 2013 Presented By: Steve Grover, President.
Development and evaluation of Passive Microwave SWE retrieval equations for mountainous area Naoki Mizukami.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
1 ISAT Module III: Building Energy Efficiency Topic 7: Transient Heating and Air Conditioning Loads  Thermal Admittance  Intermittent Heating 
Review of the New England “Mini-Pilot” DHP Evaluation Why we ignore this study.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
NEEA DEI Study Data Analysis Plan October 28, 2005 RLW Analytics, Inc. Roger L. Wright, Chairman, and Principal Consultant.
Week 6 The Energy Walk Through. Possible elements of a walk through Understand on-site information collection and listing of essential data for collection.
Multifamily Homes: Calibration Update Regional Technical Forum December 8 th, 2015.
Week 7 Utility Data Analysis. Essential Elements Identify sources for obtaining utility data: paper form, electronically or from the internet Review utility.
Regional Technical Forum Recommissioning commercial retail facilities: A whole building approach to energy savings April 7th, 2009 Presented by: Jeremy.
Development of a new Building Energy Model in TEB Bruno Bueno Supervisor: Grégoire Pigeon.
Chapter 8: The Cooling Load Cooling load is the rate at which energy must be removed from a space to maintain the temperature and humidity at the design.
A Calculator for Reliably Measuring the Savings from Advanced RTU Control Retrofits August 27, 2015 Presentation to: RTF Commercial Rooftop Unit Working.
© 2007, Itron Inc. Statistically Adjusted End-Use Model Overview & Thoughts about Incorporating DSM into a Forecast May 4, 2009 Frank A. Monforte, Ph.D.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
Inn at Otter Crest Progress Presentation by Osman Kucuk & Andrey Volodkin Team Members: Natalie Sherwood, Kevin Murray, Lee Han, Huy Tran, Aziz A.
Fort Stanwix National Monument Energy Audit Contract
WDMA Technical Conference Chicago, IL 28 June 2016
Energy Management and Planning MSJ0210
Seminar On Energy Audit Submitted To: Submitted By:
Chapter 6: INFILTRATION
Ifte Choudhury & Ashwin Balabadhrapatruni
Mixed Costs Chapter 2: Managerial Accounting and Cost Concepts. In this chapter we explain how managers need to rely on different cost classifications.
INVERSE BUILDING MODELING
Mid Semester UEB Energy Analysis of a Wastewater Treatment Plant by using Artificial Neural Network Presented by: Dr. Nor Azuana Ramli Electrical Engineering.
Energy Efficient Solutions for The Inn at Otter Crest
Chapter 14B: HEAT PUMPS AND PART LOAD ANALYSIS
Chapter 7: STEADY STATE HEAT FLOWS
Chapter 15 B: COMBINED HEAT AND POWER SYSTEMS
HCB 3-Chap 19A: All-Air Systems_Single Zone
Chapter 2C: BASIC THERMAL SCIENCES: RADIATION HEAT TRANSFER
CHAPTER 26: Inference for Regression
Chapter 6A: INFILTRATION BACKGROUND
Chapter 13B: PSYCHROMETRIC MOIST AIR PROCESSES
Sizing Methodologies • Sizing Calculations
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Chapter 4B: SOLAR IRRADIATION CALCULATION
Functions and Their Graphs
Volume 111, Issue 2, Pages (July 2016)
Behavior Modification Report with Peak Reduction Component
Calibrated Energy Models: One New Change
Figure 5.1: For coffee to be the hottest when you are ready to drink it at a later time, you should add the cream initially, not just before drinking,
Chapter 3B: INDOOR AIR QUALITY
Chapter 6B: INFILTRATION CALCULATION
Chapter 8: TRANSIENT HEAT FLOW THRU BUILDING ELEMENTS
Presentation transcript:

Chapter 10: ANNUAL ENERGY ESTIMATION METHODS Agami Reddy (rev Dec 2017) 1) Single measure methods - Degree day method for heating and cooling - Variable base degree day method - Model for generating monthly HDD - Analyzing design alternatives 2) Bin methods - Standard bin method - Model for generating monthly bin data - Modified bin method 3) Inverse modeling and utility bill analysis HCB 3- Chap 10: Annual Energy Estimation

Annual or Seasonal Energy Calculation The annual energy consumption Qyr (heating and cooling) is needed to determine operating cost (and evaluate payback) (10.1) Two of the most widely used hand-calculations are: - Single measure methods (there are a few variants) - Multiple measure methods (there are a few variants) HCB 3- Chap 10: Annual Energy Estimation

Single Measure Methods Application to residential and light commercial buildings with simple HVAC equipment where energy use is primarily driven by building loads Relies on one weather datum Three Methods: - Degree Day for heating energy use- Heating Degree Day (HDD) - Degree Day for cooling energy use- Cooling Degree Day (CDD) - Equivalent Full Load Hour (EFLH) for cooling energy use Not treated HCB 3- Chap 10: Annual Energy Estimation

Balance Point Temperature HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Degree Day (DD) Method Annual (or monthly) energy consumption of a building is proportional to the annual (or monthly) degree day of the location Specific to a selected Base (or balance) Temperature Degree Day for one month or whole year: where To is the daily average outdoor air temperature, oC or °F N is the total days in the year (or month) DD has an unit of °C-day (or oF-day) Degree Days are often tabulated at 18.3o C or 65o F base temperature "+" means that only positive values are to be counted Heating season: Eq. (10.7) HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation FIGURE 10.1 Annual heating degree-days (K-days) for the United States, for base of 65°F (18.3°C). HCB 3- Chap 10: Annual Energy Estimation

Degree Day Method for Heating Annual heating consumption is directly determined as: (10.9) HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

Cooling Degree Day (CDD) Cooling season: (10.10) Cooling DD (CDD) can be estimated knowing HDD from: (10.11) From Table 10.1, For Phoenix, annual average outdoor temperature Tav= 70o F HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Caution: CDD method does not work as well as HDD method due to such effects as solar loads, varying Ktot (window opening) or constant efficiency of cooling device HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Variable Base Degree Day Newer homes tend to have higher internal loads and lower Ktot So the traditional Tb of 18.3o C or 65o F does not apply to newer homes. So we need curves such as shown Figure 10.3 Annual heating degree-days HDD (Tbal) as function of Tbal. (a) For New York, with labels  h/year for 5°F bin centered at the point (b) For Denver, Houston, and Washington, DC, degree-days only. HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation The CDD curves for any variable base temperature can be generated from climatic data HCB 3- Chap 10: Annual Energy Estimation

Erbs et al. Empirical Correlation allows HDD to be computed knowing only monthly mean dry-bulb temperature of the location (10.17) SI (10.18) HCB 3- Chap 10: Annual Energy Estimation

Erbs et al. Empirical Correlation contd… (10.19) (10.20) HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Data needed HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Site: New York City  Reference design (design 1):  U values of opaque surfaces equivalent to 0.10 m (4 in) of fiberglass for walls and 0.15 m (6 in) for roof; conductivity of fiberglass k = 0.060 W/(m. K) [0.10 Btu/(h. ft.°F)]; double-glazed windows with U = 3.0 W/(m2 .K) [0.53 Btu/(h. ft2 .°F)]. HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

Single Measure Methods Disadvantages: Suitable for residences and small commercial (one zone) buildings Assumes continuous and constant building operation over year Not very appropriate for cooling calculations – Allows little flexibility for changes in building operation in Thermostat setback Occupancy Equipment Can not easily capture primary equipment cycling losses over year Produces results that are within ± 30 % of actual energy usage HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Bin Methods Simplified Multiple Measure – Basic Bin Method Gets its name from the way the weather data are put together Weather data are broken into temperature "bins" Each "bin" has the cumulative number of hours it has been at a given temperature range over the whole year Conventional bins are 5 °F 35 – 39 °F 40 – 44 °F 45 – 59 °F… Calculation done for each bin following: where Nbin is the number of hours in the temperature interval (or bin) centered at that temperature (10.25) HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Fig. 10.8 Bin Data for Denver, CO HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Bin Methods Advantages over Single Measure Method Captures temperature dependent information of variation in Building loads Equipment loads Captures load dependent equipment performance Degradation due to cycling Fig. 10.6 Variation of balance point temperature and internal gains for a typical house HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Bin Methods Limitations of Basic Bin Method: - Balance point temperature is not constant over day - Solar loads not treated properly - Latent loads not treated properly - Does not captures time dependent internal loads: People, lights, equipment - Improper treatment of time of day variation in HVAC operation - Failure to separately consider different zones of the building Modified Bin Method - Can treat different zones - Can treat zones with diurnal occupancy - Solar loads includes as linearized with outdoor temperature - Considers coincident wet-bulb to treat latent loads HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

Model for Generating Bin Data Erbs et al. (1983) have also proposed a correlation method for the monthly cumulative frequency distribution (CFD) of the number of hours in the month below a balance or base temperature Tbal which has been normalized as: HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation 10.19 HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Figure 10.9 Comparison of actual versus empirically generated bin data for New York City for February following Example 10.7 HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Inverse Modeling Approach which uses monitored energy data from the building to develop regression models. They are being used extensively for: Commissioning tests: to evaluate whether a component or a system is installed and commissioned properly; Comparison with design intent: to compare actual consumption with design predictions and identify causes of discrepancies, Demand Side Management (DSM): to predict reduction in electrical costs if certain operational changes are made which alter the buildings loads during on-peak hours of the day; Operation and maintenance (O&M): to predict energy savings from planned retrofits to building shell and equipment Monitoring and verification (M&V): to verify, once energy conservation measures are implemented, that the actual savings are consistent with the anticipated savings HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Utility Bill Analysis FIGURE 10.11 Variable-base degree-day model identification using electricity utility bills at a hospital. Note that some utility bills have been excluded from the regression due to a degree-day threshold. (a) Left graph shows bills vs. time, (b) right graph shows bills vs. cooling degree-days (Courtesy of Sonderegger, 1998) HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation 2-P cooling Single Variate Change-Point Models 1-P 3-P heating 3-P cooling Steady-state, single-variate models appropriate for modeling energy use in residential and commercial buildings- such models can be used to regress utility bills (MMT), as well as daily or hourly energy use A non-linear modeling approach is needed for 3-P models and higher. Specialized software has been developed for this purpose 4-P heating 4-P cooling 5-P Fig. 10.12 HCB 3- Chap 10: Annual Energy Estimation

M&V Requires Modeling Determining savings from energy conservation measures Figure 10.14 Scatter plot showing how daily cooling energy use varies with outdoor temperature for a large university building in Texas The faint dots correspond to initial energy use, while the dark circles correspond to energy use after energy efficiency improvements were made to the building. HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Process of determining the best model fit for a specific project involves fitting all forms of change point models and selecting the one with the least root mean square error (RMSE) HCB 3- Chap 10: Annual Energy Estimation

HCB 3- Chap 10: Annual Energy Estimation Outcomes Be familiar with the general classification of energy estimation methods and advantages of multiple measure methods over single measure methods Understand the basis of single measure methods, to what types of structures they are applicable and the concept of degree-day Be able to solve problems involving heating degree-day method (HDD) and cooling degree-day (CDD) method Familiarity with the Erbs et al. approach to generate monthly HDD for any location Understand the basis of the bin method and to what type of structures it is applicable Be able to solve problems involving the basic bin method Familiar with the Erbs et al. approach to generate monthly bin data for any location Understand the basis of the modified bin method and its advantage over the bin method Familiarity with inverse methods and their usefulness applicable to M&V Understand how the DD concept is used for utility bill modeling Familiarity with different change point model functional forms and how models are identified from data HCB 3- Chap 10: Annual Energy Estimation