2018 Updates May 2018.

Slides:



Advertisements
Similar presentations
Code Analysis:Accessibility Colleen MacEachern & Stephanie Novak.
Advertisements

2009 Edition – NFPA 101 Steve Hornyak, DAHC, CDT, FDAI
OSHA Office of Training and Education
Electronic Locking and Exemption Request Form Training
VL Connector To introduce the VL wire-to-board and wire-to-wire, crimp style connector series.
2015 Update to OBC September 17, 2014.
By: Alex Sowa Electrical Projects April 10 th, 2013.
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
Trouble - Shooting ELR - Electric Latch Retraction.
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
Corporate Profile June the right touch in door controls! The right company The right products The right support Camden is The right partner for.
Model 3000 Magnetic Lock 1500 lbs. Holding Force Fas-Trak Mounting System 12 or 24 VDC or VAC field selectable One Piece Housing Low Power Consumption.
FIRE ESCAPE Christina Joy Chambers IND 5615 Fall 2011.
EGRESS AND FIRE PROTECTION
Architectural CAD I – IM230 Vocabulary. GROUP 3 Vocabulary.
1/05 Means of Egress WAC School Safety Training.
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Safety Training Presentation
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
The Monitor 4000 Alarm provides the most cost effective, worry-free method of keeping backdoors secure during business hours…protecting your business,
Pre Load Strikes for Cylindrical Locksets 20 SERIES PRE LOAD STRIKES.
code calculations, construction drawings
Exit Routes and Fire Protection
Area of Refuge It’s the Law!
City of Ottawa Update to Accessibility Design Standards (ADS) Second Edition released November 2015 Jo-anne Moore, P.Eng. Senior Engineer, Guidelines and.
Means of Egress Don Ebert- Risk Manager (509)
Control and signalling Harmony Easy XA2E Ø 22 mm, plastic push-buttons, switches with metallic-look ring Introducing the Easy line Essential automation.
1 ALARMLINC. 2 OVERVIEW Expanding Situational AwarenessOVERVIEW.
Fluid Power Control.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Select your System Freedom Micro DI.
“Electromagnetic Locks, Electric Strikes
Asahi/America Electric Actuators
New Electric Actuators EA Type
Accessible Environment
ModICE Modular Integrated Connector Enclosure
AUTOMATIC STREET LIGHT CONTROL USING LDR
DESCRIPTION AND GUIDE TO OPERATIONS
Connections Topology of Apollo ACS.
Asahi/America Electric Actuators Series 94.
Actuators and directional control valves
The Electrical Diagram
Analog Room Command Module
Fire Door Inspections Qualified Training
2N® Access Unit Touch Keypad
Product Training Module
Asahi/America Electric Actuators
Industrial Electronics
Accessibility for Ontarians with Disabilities Act
CM-75 SERIES PUSH PLATE SWITCHES No One Does Wireless Door
Open-Voice Analog Apartment Intercoms
Building Emergency Evacuation Plan (BEEP) Training for Building Emergency Coordinators and Alternates.
Campus Ministry Accessibility
Hitchcock architectural barriers: Part 1
Hannah Ehresman, Kelsey Russell, Kaitlyn Higgins, Lynette Akai
Flotection: Building Main Shutoff System
Asahi/America Electric Actuators Series 94.
Product Training Module
Open-Voice Analog Apartment Intercoms
Area of Refuge It’s the Law!
Telephone Entry and Digital Dial Systems
An Introduction. An Introduction An Introduction Atlas steel lockers are the ultimate solution when it comes to versatile, durable personal storage.
An Introduction. An Introduction An Introduction Atlas steel lockers are the ultimate solution when it comes to versatile, durable personal storage.
S.T.R. Apartment Video-Intercom System
Accelerator PSS Radiation Monitoring
PSS0 Design & Concept of Operations
ENTER OUR FRIEND MR. RELAY
Building Emergency Evacuation Plan (BEEP) Training for Building Emergency Coordinators and Alternates.
Fluid Power System Electrical Control
Presentation transcript:

2018 Updates May 2018

About Camden Door Controls Establish in 1988 Independent, Canadian owned Co. Product design, manufacturing and warehousing in Mississauga, Ontario ISO 9001 certified manufacturer We are Canada’s leading manufacturer of door controls, activation and locking products We offer more than 4,000 models of activation switches Serving the automatic door and access control markets Our automatic door accessory products are compatible with all makes of automatic door operators.

368/13 Amendment to OBC Ontario Regulation 368/13 was filed to amend the 2012 Ontario Building Code, effective January 1, 2015. The amended requirements substantially enhances accessibility in newly constructed buildings, and existing buildings that are to be extensively renovated. The Building Code requires barrier-free washrooms to be provided in public areas of most buildings. These washrooms must be situated on a barrier-free path of travel and are subject to a number of requirements addressing turning space, doorway widths, grab bars, counter heights and signage, among others.

368/13 Amendment to OBC New amendments update these requirements in a number of ways. Key changes include: • Requirements for power door operators at the entrance door to all barrier-free and universal washrooms. • Universal washroom in all buildings in which a washroom is required, including the requirement for code compliant Emergency Call Systems. • Multi-storey buildings must provide one universal washroom for every three floors. The location is not specified – this sets out the number, but leaves flexibility for designers to locate the universal washrooms where appropriate.

All Barrier Free Systems Activation Switches

All Barrier Free Systems – Activation Switches

All Barrier Free Systems – Activation Switches

All Barrier Free Systems – Activation Switches

All Barrier Free Systems OBC COMPLIANT NARROW PUSH PLATE SWITCHES Camden has updated all our narrow switches with 2” x 4” actuation plates. CM-35N Narrow Jamb Switch CM-35 Single Gang Narrow Switch CM-2520 Vestibule Switch

All Barrier Free Systems – Activation Switches

All Barrier Free Systems – Activation Switches

All Barrier Free Systems – Activation Switches

Barrier Free Systems In Restrooms Restroom Control Systems

Restroom Control Systems – Basic Components Low Energy Swing Door Operator (by others) Door Control Relay Interconnects door operator, activation switches, electric lock and annunciation Door Activation Switches Push Plate or Hands Free switches. One inside restroom and one outside Restroom.

Restroom Control Systems – Basic Components Magnetic Door Contact This device monitors the door status. When door is opened, the door control relay is reset to unlocked status. ‘Push To Lock’ Switch Push plate switch or mushroom push button. Switch type and placement not defined as door activation switches under OBC. Electric Strike or Magnetic Lock 24VDC, typically grade 2 strike for cylindrical locksets, fail safe/fail secure

Restroom Control Systems – Basic Design

Restroom Control Systems – Enhancement ‘Occupied When Lit’ Visual Annunciation Without annunciation, building occupants will not know why a ‘push to open’ switch outside the washroom does not operate. ‘Occupied When Lit’ Annunciator Single gang LED indicator with ‘white out’ text (cannot be seen when de-energized). CM-AF500 Aura™ Illuminated Push Plate & Sign Aura™ combines door activation and annunciation in one device. Eliminates Multiple devices and improves usability.

Restroom Control Systems – CM-AF500

Restroom Control Systems – Aura™ Aura™ Surface & Flush Enclosures, Selectable Blue/Green/Red Aura™ gives you the option for surface or flush mounting, with field selection of blue, green and red illumination, as idled or active color. CM-45/854SE1 Surface ‘push to lock’ with sign CM-45/454SE1 Surface ‘wheelchair & push to open’ with sign CM-45/855SE1 Flush ‘push to lock’ with sign CM-45/455SE1 Flush ‘wheelchair & push to open’ with sign

Restroom Control Systems – Aura™ (CM-45)

Restroom Control Systems – Enhancement ‘Locked When Lit’ Visual Annunciation Without annunciation, building occupants do not have a visual indication that the ‘Push to Lock’ switch has locked the door. Double gang, mushroom push button and LED annunciator ‘Push to Lock’ switch and LED indicator, with ‘white out’ text (invisible until energized). CM-AF500 Aura™ Combo Illuminated Push Plate & Sign Combines ‘Push to Open’ and ‘Push to Lock’ switches, Aura™ lock status indication and sign in one device. CM-25204855SE1

Restroom Control Systems – Aura™ (CM-2520)

Restroom Control Systems – Touchless Switches Restroom Control System Kits With SureWave™ touchless switches! Camden is the 1st manufacturer to offer a touchless switch restroom control system. SureWave™ touchless switches have been proven in thousands of applications and the ‘push to open’ touchless switch has been specifically designed to prevent false activation. CX-WC16 includes: CX-33 controller CM-331/43S-SGLR ‘Wave to Lock’ switch CM-331/42WS-SGLR Wave to Open’ switch CM-325/42WS ‘Wave to Open’ switch CX-MDA N/C surface mount Door Contact.

Restroom Control Systems – Touchless Switches

Restroom Control Systems – 2 Door System

Emergency Call For Universal Washrooms Emergency Call Systems

368/13 Amendment to OBC 3.8.3.12. Universal Washrooms (1) A universal washroom shall b) have a door that is capable of being locked from the inside and released from the outside in case of emergency and that has, (i) a graspable latch-operating mechanism located not less than 900 mm and not more than1000 mm above the finished floor, (iii) if it is an outward swinging door, a door closer, spring hinges or gravity hinges, so that the door closes automatically

368/13 Amendment to OBC 3.8.3.12. Universal Washrooms (2) A universal washroom shall have, (a) an emergency call system that consists of audible and visual signal devices inside and outside of the washroom that are activated by a control device inside the washroom, and (b) an emergency sign that contains the words IN THE EVENT OF AN EMERGENCY PUSH EMERGENCY BUTTON AND AUDIBLE AND VISUAL SIGNAL WILL ACTIVATE in letters at least 25 mm high with a 5 mm stroke and that is posted above the emergency button.

Emergency Call Systems – Components ‘Press For Emergency Assistance’ Switch The type or placement of switch is not defined by code but must have the ability to latch upon activation and be reset. Camden suggests a large ADA compliant mushroom button with ‘Push/Pull’ activation. Alternative momentary switches will require an additional latching relay and reset device. Audible & Visual Signal (Inside) The type of signal device is not defined by code but consideration should be given to loudness. A siren/strobe designed for fire alarm application is not recommended. Camden developed a signal device specifically for this application.

Emergency Call Systems – Components Audible & Visual Signal (Outside) The type or placement of signal device is not defined by code. Camden suggests a dome light with sounder, that can be easily seen and heard along corridors. Instructional Sign The placement of the sign inside the washroom is not defined by code. Camden suggests that the sign is placed directly above the ‘Press for Emergency Assistance’ switch and audible and visual signal device. Camden offers signs on Self-adhesive vinyl (ideal for drywall) and 1/16” Board (ideal for brick and rough surfaces).

Emergency Call System – Design CX-WEC10 UNIVERSAL RESTROOM KIT

Emergency Call System – Design CX-WEC10 EMERGENCY CALL & CX-WC13 BARRIER FREE RESTROOM SYSTEM

Emergency Call Systems - New Latching Relay Kits For Momentary Switches Camden now offers emergency. call system kits for use with momentary ‘press for assistance’ switches, including tape (ribbon) switches. CX-WEC12 Emergency Call System Kit w/ push button system reset. CX-WEC13 Emergency Call System Kit w/ key switch system reset.

Emergency Call Systems – New ‘Press For Emergency Assistance’ Switch & LED Annunciator Combo CM-AF540SO Double gang combo for ‘press for assistance’ Push button and LED annunciator, with adjustable Sounder. Also Available In a System Kit CX-WEC10K2 Includes CM-AF540SO combo, CM-AF140SO dome light w/ sounder and CM-SE21A (Eng.) instructional Signage.

Emergency Call Systems – New Dome Light with Sounder (Available May 2017) CM-AF141SO Camden’s new dome light w/ sounder has been specifically designed for restroom control applications: Weather Resistant Vandal Resistant Super bright LED illumination Adjustable 95dB sounder ‘Assistance Required’ text, with option for Eng., Fr. or Bilingual

Support Services For Project Specifiers

Support Services Camden has included 3 part project specifications, CAD drawings and shop drawing documents in ‘Lunch & Learn’ presentation package. Camden barrier free and emergency call systems are stock products, ready to ship next day from receipt of order. Camden products are sold through an extensive network of authorized distributors across Canada. Camden is ready to meet special project needs with custom products and unique system design documentation.

Thank You!