Disks.

Slides:



Advertisements
Similar presentations
Hard Disks Low-level format- organizes both sides of each platter into tracks and sectors to define where items will be stored on the disk. Partitioning:
Advertisements

Hard Disk Drives Chapter 7.
Faculty of Information Technology Department of Computer Science Computer Organization Chapter 7 External Memory Mohammad Sharaf.
RAID Oh yes Whats RAID? Redundant Array (of) Independent Disks. A scheme involving multiple disks which replicates data across multiple drives. Methods.
Hands-on RAID on Moxa Computer Prepared by: (40min) Date: mm-dd-yyyy.
Linux Installation LINUX INSTALLATION. Download LINUX Linux Installation To install Red Hat, you will need to download the ISO images (CD Images) of the.
“Redundant Array of Inexpensive Disks”. CONTENTS Storage devices. Optical drives. Floppy disk. Hard disk. Components of Hard disks. RAID technology. Levels.
RAID- Redundant Array of Inexpensive Drives. Purpose Provide faster data access and larger storage Provide data redundancy.
Disks. Computer Center, CS, NCTU 2 Outline  Interfaces  Geometry  Add new disks Installation procedure Filesystem check Add a disk using sysinstall.
REDUNDANT ARRAY OF INEXPENSIVE DISCS RAID. What is RAID ? RAID is an acronym for Redundant Array of Independent Drives (or Disks), also known as Redundant.
Chapter 22 All About SCSI.
Other Disk Details. 2 Disk Formatting After manufacturing disk has no information –Is stack of platters coated with magnetizable metal oxide Before use,
Chapter 8 Adding a Disk. Computer Center, CS, NCTU 2 Disk Interface  SCSI Small Computer Systems Interface High performance and reliability  IDE (or.
Laksh mi.  fdisk is an interactive utility to manipulate disk partitions.  Use fdisk –l to review the disks and partitions on the system.  Use fdisk.
Chapter 8: Adding a Disk — Unix Hard Disk Basics Installation and Configuration Barry Kane CMSC-691X.
IDE and SCSI Devices Terms and Definitions.
Hard Drive.
Servers Redundant Array of Inexpensive Disks (RAID) –A group of hard disks is called a disk array FIGURE Server with redundant NICs.
Session 3 Windows Platform Dina Alkhoudari. Learning Objectives Understanding Server Storage Technologies Direct Attached Storage DAS Network-Attached.
Secondary Storage Unit 013: Systems Architecture Workbook: Secondary Storage 1G.
RAID Redundancy is the factor for development of RAID in server environments. This allows for backup of the data in the storage in the event of failure.
Copyright © 2007 Heathkit Company, Inc. All Rights Reserved PC Fundamentals Presentation 20 – The Hard Drive Interface.
CENG334 Introduction to Operating Systems Erol Sahin Dept of Computer Eng. Middle East Technical University Ankara, TURKEY URL:
1 Chapter Overview CD-ROM and DVD Drives Advanced Hard Disk Drives SCSI Drives.
A+ Guide to Managing and Maintaining Your PC Fifth Edition Chapter 8 Understanding and Installing Hard Drives.
RAID Shuli Han COSC 573 Presentation.
Chapter 6 Advanced Installation. Objectives  Describe the types and structure of SCSI devices  Explain the different levels of RAID and types of RAID.
Day 10 Hardware Fault Tolerance RAID. High availability All servers should be on UPSs –2 Types Smart UPS –Serial cable connects from UPS to computer.
Device and Filesystem Management CSCI N321 – System and Network Administration Copyright © 2000, 2012 by Scott Orr and the Trustees of Indiana University.
Disk Access. DISK STRUCTURE Sector: Smallest unit of data transfer from/to disk; 512B 2/4/8 adjacent sectors transferred together: Blocks Read/write heads.
 SCSI › Small Computer Systems Interface › High performance and reliability  IDE (or ATA) › Integrated Device Electronics (or AT Attachment) › Low cost.
Guide to Linux Installation and Administration, 2e 1 Chapter 9 Preparing for Emergencies.
Understanding and Troubleshooting Your PC. Chapter 5: Understanding, Installing, and Troubleshooting Disk Drives2 Chapter Objectives  In this chapter,
Linux+ Guide to Linux Certification, Third Edition Chapter 6 Advanced Installation.
1 Interface Two most common types of interfaces –SCSI: Small Computer Systems Interface (servers and high-performance desktops) –IDE/ATA: Integrated Drive.
Managing Disks and Drives Chapter 13 powered by dj.
Disks. Computer Center, CS, NCTU 2 Outline  Interfaces  Geometry  Add new disks Installation procedure Filesystem check Add a disk using sysinstall.
Windows Server 2003 硬碟管理與磁碟機陣列 林寶森
Device and Filesystem Management CSCI N321 – System and Network Administration Copyright © 2000, 2010 by Scott Orr and the Trustees of Indiana University.
System Administration – Part 2. Devices in UNIX are files: A device can be accessed with different file names All device files are stored in /dev or its.
Chapter 8: Installing Linux The Complete Guide To Linux System Administration.
1 CEG 2400 Fall 2012 Network Servers. 2 Network Servers Critical Network servers – Contain redundant components Power supplies Fans Memory CPU Hard Drives.
Hands-On Microsoft Windows Server 2008 Chapter 7 Configuring and Managing Data Storage.
Enhanced Availability With RAID CC5493/7493. RAID Redundant Array of Independent Disks RAID is implemented to improve: –IO throughput (speed) and –Availability.
RAID TECHNOLOGY RASHMI ACHARYA CSE(A) RG NO
Network-Attached Storage. Network-attached storage devices Attached to a local area network, generally an Ethernet-based network environment.
Silberschatz, Galvin and Gagne ©2013 Operating System Concepts – 9 th Edition Chapter 10: Mass-Storage Systems.
Linux Filesystem Administration
CSCE 385: Computer Architecture Spring 2014 Dr. Mike Turi I/O.
I/O Errors 1 Computer Organization II © McQuain RAID Redundant Array of Inexpensive (Independent) Disks – Use multiple smaller disks (c.f.
Chapter 8 Adding a Disk.
Disks frank.
Disks and Formatting Ch 3.
Chapter 11: File System Implementation
Multiple Platters.
Chapter 12: File System Implementation
I/O System Chapter 5 Designed by .VAS.
IDE and SCSI Devices Terms and Definitions. Chapter Objectives After completing this chapter you will: Understand hard drive terminology. Understand the.
Hard Drive Technologies
Direct Attached Storage and Introduction to SCSI
RAID RAID Mukesh N Tekwani
Operating System Module 1: Linux Installation
Chapter Overview CD-ROM and DVD Drives Advanced Hard Disk Drives
Linux+ Guide to Linux Certification, Third Edition
UNIT IV RAID.
Adding a Disk Chapter 8.
RAID RAID Mukesh N Tekwani April 23, 2019
Hard disk basics Prof:R.CHARLES SILVESTER JOE Departmet of Electronics St.Joseph’s College,Trichy.
Storage Management Lecture 7.
Improving performance
Presentation transcript:

Disks

Outline Interfaces Geometry Add new disks RAID Appendix – SCSI & SAS Installation procedure Filesystem check Add a disk using sysinstall RAID GEOM Appendix – SCSI & SAS

Disk Interfaces SCSI IDE (or ATA) SATA SAS USB Small Computer Systems Interface High performance and reliability IDE (or ATA) Integrated Device Electronics (or AT Attachment) Low cost Become acceptable for enterprise with the help of RAID technology SATA Serial ATA SAS Serial Attached SCSI USB Universal Serial Bus Convenient to use

Disk Interfaces – ATA & SATA ATA (AT Attachment) ATA2 PIO, DMA LBA (Logical Block Addressing) ATA3, Ultra DMA/33/66/100/133 ATAPI (ATA Packet Interface) CDROM, TAPE Only one device can be active at a time SCSI support overlapping commands, command queuing, scatter-gather I/O Master-Slave 40-pin ribbon cable SATA Serial ATA SATA-1 1.5Gbit/s, SATA-2 3Gbit/s, SATA-3 6GBit/s

Disk Interfaces – ATA & SATA Interfaces ATA interface and it’s cable SATA interface and it’s cable

Disk Interfaces – USB IDE/SATA to USB Converter

Disk Geometry (1) sector track cylinder Position Individual data block circle cylinder circle on all platters Position CHS Cylinder, Head, Sector

Disk Geometry (2) 40G HD 4866 cylinders, 255 heads 63 sectors per track, 512 bytes per sector 512 * 63 * 4866 * 255 = 40,024,212,480 bytes 1KB = 1024 bytes 1MB = 1024 KB = 1,048,576 bytes 1GB = 1024 MB = 1,073,741,824 bytes 40,024,212,480 / 1,073,741,824 ≒ 37.275 GB

Disk Installation Procedure

Disk Installation Procedure (1) The procedure involves the following steps: Connecting the disk to the computer IDE: master/slave SATA SCSI: ID, terminator power Creating device files Auto created by devfs Formatting the disk Low-level format Address information and timing marks on platters bad sectors Manufacturer diagnostic utility

Disk Installation Procedure (2) Partitioning and Labeling the disk Allow the disk to be treated as a group of independent data area root, home, swap partitions Suggestion: /var, /tmp  separate partition Make a copy of root filesystem for emergency Establishing logical volumes Combine multiple partitions into a logical volume Software RAID technology GEOM: geom(4)、geom(8) ZFS: zpool(8)、zfs(8)、zdb(8)

Disk Installation Procedure (3) Creating UNIX filesystems within disk partitions Use “newfs” to install a filesystem for a partition Filesystem components A set of inode storage cells A set of data blocks A set of superblocks A map of the disk blocks in the filesystem A block usage summary

Disk Installation Procedure (4) Superblock contents The length of a disk block Inode table’s size and location Disk block map Usage information Other filesystem’s parameters sync The sync() system call forces a write of dirty (modified) buffers in the block buffer cache out to disk. The sync utility can be called to ensure that all disk writes have been completed before the processor is halted in a way not suitably done by reboot(8) or halt(8).

Disk Installation Procedure (5) mount Bring the new partition to the filesystem tree mount point can be any directory # mount /dev/ad1s1e /home2 Setting up automatic mounting Automount at boot time /etc/fstab % mount –t ufs /dev/ad2s1a /backup % mount –t cd9600 –o ro,noauto /dev/acd0c /cdrom liuyh@NASA:/etc> cat fstab # Device Mountpoint Fstype Options Dump Pass# /dev/ad0s1b none swap sw 0 0 /dev/ad2s1b none swap sw 0 0 /dev/ad0s1a / ufs rw 1 1 /dev/acd0 /cdrom cd9660 ro,noauto 0 0 /dev/ad2s1a /backup ufs rw,noauto 2 2 csduty:/bsdhome /bsdhome nfs rw,noauto 0 0

Disk Installation Procedure (6) Setting up swapping on swap partitions swapon, swapoff, swapctl swapinfo, pstat

fsck – check and repair filesystem (1) System crash will cause Inconsistency between memory image and disk contents fsck Examine all local filesystem listed in /etc/fstab at boot time. (fsck -p) Automatically correct the following damages: Unreferenced inodes Inexplicably large link counts Unused data blocks not recorded in block maps Data blocks listed as free but used in file Incorrect summary information in the superblock fsck(8)、fsck_ffs(8) ffsinfo(8): dump metadata

fsck – check and repair filesystem (2) Run fsck in manual to fix serious damages Blocks claimed by more than one file Blocks claimed outside the range of the filesystem Link counts that are too small Blocks that are not accounted for Directories that refer to unallocated inodes Other errors fsck will suggest you the action to perform Delete, repair, …

Adding a disk to FreeBSD (1) Check disk connection Look system boot message Use /usr/sbin/sysinstall to install the new HD Configure  Fdisk  Label Don’t forget to “W” the actions Easiest approach, but has some problems. fdisk(8), bsdlabel(8), newfs(8) Make mount point and mount it # mkdir /home2 # mount –t ufs /dev/ad3s1e /home2 # df Edit /etc/fstab ad3: 238475MB <Hitachi HDS722525VLAT80 V36OA6MA> at ata1-slave UDMA100

Adding a disk to FreeBSD (2) If you forget to enable soft-update when you add the disk % umount /home2 % tunefs –n enable /dev/ad3s1e % mount –t ufs /dev/ad3s1e /home2 % mount /dev/ad0s1a on / (ufs, local, soft-updates) /dev/ad1s1e on /home (ufs, local, soft-updates) procfs on /proc (procfs, local) /dev/ad3s1e on /home2 (ufs, local, soft-updates)

RAID

RAID – (1) Redundant Array of Inexpensive Disks A method to combine several physical hard drives into one logical unit Depending on the type of RAID, it has the following benefits: Fault tolerance Higher throughput Real-time data recovery RAID Level RAID 0, 1, 0+1, 2, 3, 4, 5, 6 Hierarchical RAID

RAID – (2) Hardware RAID Software RAID There is a dedicate controller to take over the whole business RAID Configuration Utility after BIOS Create RAID array, build Array Software RAID GEOM CACHE、CONCAT、ELI、JOURNAL、LABEL、MIRROR、MULTIPATH、NOP、PART、RAID3、SHSEC、STRIPE、VIRSTOR ZFS JBOD、STRIPE MIRROR RAID-Z、RAID-Z2、RAID-Z3

RAID 0 Stripped data intro several disks Minimum number of drives: 2 Advantage Performance increase in proportional to n theoretically Simple to implement Disadvantage No fault tolerance Recommended applications Non-critical data storage Application requiring high bandwidth (such as video editing)

RAID 1 Mirror data into several disks Minimum number of drives: 2 Advantage 100% redundancy of data Disadvantage 100% storage overage Moderately slower write performance Recommended application Application requiring very high availability (such as home)

RAID 0+1 Combine RAID 0 and RAID 1 Minimum number of drives: 4

RAID 2 Hamming Code ECC Each bit of data word Advantages: "On the fly" data error correction Disadvantages: Inefficient Very high ratio of ECC disks to data disks Recommended Application No commercial implementations exist / not commercially viable

RAID 3 Parallel transfer with Parity Minimum number of drives: 3 Advantages: Very high data transfer rate Disadvantages: Transaction rate equal to that of a single disk drive at best Recommended Application Any application requiring high throughput

RAID 4 Similar to RAID3 RAID 3 V.S RAID 4 Byte Level V.S Block Level Block interleaving

RAID 5 Independent Disk with distributed parity blocks Minimum number of drives: 3 Advantage Highest read data rate Medium write data rate Disadvantage Disk failure has a medium impact on throughput Complex controller design When one disk failed, you have to rebuild the RAID array “write hole”

RAID 6 Similar to RAID5 Minimum number of drives: 4 2 parity checks, 2 disk failures tolerable.

Modular Disk Transformation Framework GEOM Modular Disk Transformation Framework

GEOM – (1) Support ELI – geli(8): cryptographic GEOM class JOURNAL – gjournal(8): journaled devices LABEL – glabel(8): disk labelization MIRROR – gmirror(8): mirrored devices STRIPE – gstripe(8): striped devices … http://www.freebsd.org/doc/handbook/geom.html

GEOM – (2) GEOM framework in FreeBSD Kernel support Major RAID control utilities Kernel modules (/boot/kernel/geom_*) Name and Prodivers “manual” or “automatic” Metadata in the last sector of the providers Kernel support {glabel,gmirror,gstripe,g*} load/unload device GEOM_* in kernel config geom_*_enable=“YES” in /boot/loader.conf

GEOM – (3) LABEL Used for GEOM provider labelization. Kernel glabel device GEOM_LABEL geom_label_load=“YES” glabel # glabel label -v usr da2 # newfs /dev/label/usr # mount /dev/label/usr /usr # glabel stop usr # glabel clear da2 UFS label # tunefs -L data /dev/da4s1a # mount /dev/ufs/data /mnt/data

GEOM – (4) MIRROR Used for GEOM provider labelization. Kernel gmirror device GEOM_MIRROR geom_mirror_load=“YES” gmirror # gmirror label -v -b round-robin data da0 # newfs /dev/mirror/data # mount /dev/mirror/data /mnt # gmirror insert data da1 # gmirror forget data # gmirror stop data # gmirror clear da0

GEOM – (5) STRIPE Used for GEOM provider labelization. Kernel gstripe device GEOM_STRIPE geom_stripe_load=“YES” gstripe # gstripe label -v -s 131072 data da0 da1 da2 da3 # newfs /dev/stripe/data # mount /dev/stripe/data /mnt # gstripe stop data # gstripe clear da0

Appendix SCSI & SAS

Disk Interfaces – SCSI Interface Evolution Version Freq. Width Speed Length Diff. SCSI-1 5MHz 8 bits 5MB/s 6m 25m SCSI-2 SCSI-2 Fast 10MHz 10MB/s 3m SCSI-2 Fast Wide 16 bits 20MB/s Ultra SCSI 20MHz 1.5m Ultra Wide SCSI 40MB/s Ultra2 SCSI 40MHz 80MB/s - 12m Ultra160 SCSI 80MHz 160MB/s Ultra320 SCSI 160MHz 320MB/s

Disk Interfaces – SCSI Interface Connector

Disk Interfaces – SCSI Interface Daisy chain on SCSI bus Most external devices have two SCSI ports Terminator Each SCSI device has a SCSI ID

Disk Interfaces – SAS SAS – Serial Attached SCSI SAS vs parallel SCSI SAS uses Serial transfer protocol to interface multiple devices hence lesser signaling overhead than parallel SCSI, resulting in higher speed. No bus contention as SAS bus is point-to-point while SCSI bus is multidrop. Each device is connected by a dedicated bus to the initiator. Connection through expanders may appear to cause some contention, but this is transparent to the initiator. SAS has no termination issues and does not require terminator packs like parallel SCSI. SAS eliminates skew. SAS supports higher number of devices (> 16384) while Parallel SCSI limits it to 16 or 32. SAS supports higher transfer speed (1.5, 3.0 or 6.0 Gbps). The speed is realized on each initiator-target connection, hence higher throughput whereas in parallel SCSI the speed is shared across the entire multidrop bus. SAS supports SATA devices. SAS uses SCSI commands to interface with SAS End devices.