TAXUS II and IV: two-year follow-up

Slides:



Advertisements
Similar presentations
ENDEAVOR IV Acronym: ENDEAVOR IV. Lead investigator: Dr Martin Leon from Columbia University, New York Source: Transcatheter cardiovascular Therapeutics,
Advertisements

Copyleft Clinical Trial Results. You Must Redistribute Slides PEPCAD II ISR Study Paclitaxel-eluting devices: randomized comparison of the SeQuent™ please.
Www. Clinical trial results.org The C-SIRIUS Study A The Canadian Multi-Center, Randomized, Double-Blind Study of the Sirolimus-Eluting Stent in the Treatment.
“Real World”: SVG, De Novo or Restenotic Coronary Artery Lesions Chronic Stable Angina, Silent Ischemia, Acute Coronary Syndromes Vessel Diameters:
Www. Clinical trial results.org  Major Endpoints: Death, MI, stent thrombosis, TLR, TVR, MACE, and CKMB >3x nl  Major Endpoints: Death, MI, stent thrombosis,
Www. Clinical trial results.org The RAVEL Study A RAndomised (double blind) study with the Sirolimus coated BX™ VElocity balloon expandable stent (CYPHER™)
3rd CEEGI Advisory Board1 Resolute in the DES era: Indications & Limitations Georgios I. Papaioannou, MD, MPH, FACC, FSCAI Athens Medical Center Cardiac.
Basel Stent Cost-effectiveness Trial-Late Thrombotic Events (BASKET LATE) Trial Basel Stent Cost-effectiveness Trial-Late Thrombotic Events (BASKET LATE)
Arterial Revascularization Therapies Part II: a non- randomized comparison of contemporary PCI and coronary artery bypass grafting (CABG) in patients with.
The REALITY Study Results. REALITY Study Design The REALITY Study : Prospective randomized clinical trial to evaluate the safety and efficacy of CYPHER®
Rapamycin- and Paclitaxel-Eluting Stents With Identical Biodegradable Polymeric Coating and Design Trial Presented at The American College of Cardiology.
1 of Presented by Gregg W. Stone, MD, ACC PROMUS Stent is a private-labeled Xience V Everolimus Eluting Coronary Stent System manufactured.
Treatment of In-Stent Restenosis by Paclitaxel Coated PTCA Balloons Presented at The American Heart Association Scientific Session 2006 Presented by Dr.
TAXUS ATLAS Trial Presented at The EuroPCR meeting Paris, France May 2006 Presented by Dr. Mark Turco TAXUS ATLAS 9-Month Results: Evaluation of TAXUS.
Basel Stent Cost-Effectiveness (BASKET) Trial BASKET Trial Presented at The European Society of Cardiology Hotline Session 2005 Presented by Dr. Matthias.
Paclitaxel Eluting Stent Versus Conventional Stent in ST-segment Elevation Myocardial Infarction (PASSION) Trial Presented at The American College of Cardiology.
Slow-rate release polymer-based paclitaxel- eluting stent compared with bare stent in patients with single complex coronary lesions TAXUS V Presented at.
A Prospective, Randomized Trial Evaluating a Paclitaxel-Eluting Balloon in Patients TReated with Endothelial Progenitor Cell CapTuring Stents for De Novo.
Endeavor 4: A Randomized Comparison of a Zotarolimus- Eluting Stent and a Paclitaxel- Eluting Stent in Patients with Coronary Artery Disease Martin B.
Www. Clinical trial results.org Cypher sirolimus-eluting stent Primary Endpoint:  In-stent and late lumen loss at 9 months (determined by QCA) Secondary.
Boston Scientific Drug eluting stent program A Scientific Approach Identify therapeutic agent Identify appropriate polymer carrier Evaluate a broad range.
Date of download: 7/8/2016 Copyright © The American College of Cardiology. All rights reserved. From: Randomized Trial of Paclitaxel- Versus Sirolimus-Eluting.
Trial to Assess the Use of the Cypher Stent in Acute Myocardial Infarction Treated with Balloon Angioplasty (TYPHOON) Trial Presented at The American College.
Final 5 year results from the all-comer COMPARE trial: a prospective randomized comparison between Xience-V and Taxus Liberté TCT 2013 San Francisco Pieter.
Harvard Clinical Research Institute, Boston, US
XIENCE V vs TAXUS: Game Over! The Studies are Definitive
TAXUS II: Slow Release Formula An International, Randomized, Multicenter, Blinded Trial of TAXUSTM NIRxTM SR Stent Presented at TCT 2002.
NORSTENT Trial design: Patients with obstructive coronary artery disease were randomized to a drug-eluting stent (DES) (n = 4,504) versus a bare-metal.
Volume 54, Issue 1, Pages (August 2009)
For the HORIZONS-AMI Investigators
LONG-DES II Trial Randomized Comparison of the Efficacy of Sirolimus-Eluting Stent Versus Paclitaxel-Eluting Stent in the Treatment of Long Native Coronary.
TAXUS IV Trial Slow-rate release polymer-based paclitaxel-eluting stent compared with bare stent in patients with single de novo coronary lesions Presented.
DES Should be Used as the Default Stent in ACS!
Stenting of Coronary Arteries in Non Stress/Benestent Disease
SIRIUS Trial: Diameter Restenosis
The American College of Cardiology Presented by Dr. Maurits T. Dirksen
Background There is ongoing debate to identify the most effective drug-eluting stent between the two currently most used devices (ie, sirolimus- [SES]
American College of Cardiology Presented by Dr. Stephan Windecker
TAXUS II: Moderate Release Formula An International, Randomized, Multicenter, Blinded Trial of TAXUSTM NIRxTM MR Stent Presented at TCT 2002.
REALITY: 8 month results
Kyoto University Hospital, Japan
ENDEAVOR IV: 5 Year Final Outcomes
For the HORIZONS-AMI Investigators
For the HORIZONS-AMI Investigators
Presented at ACC 2003 Late Breaking Clinical Trials
The American College of Cardiology Presented by Dr. Raimund Erbel
Large-Scale Registry Examining Safety and Effectiveness of Zotarolimus-Eluting and Sirolimus-Eluting Stents in Patients with Coronary Artery Disease Western.
SIRIUS: A U.S. Multicenter, Randomized, Double-Blind Study of the SIRolImUS-Eluting Stent in De Novo Native Coronary Lesions Presented at TCT 2002.
American Heart Association Presented by Dr. Julinda Mehilli
(p = 0.32 for noninferiority)
Drug-eluting stents for in-stent restenosis
ENDEAVOR II Five-Year Clinical Follow-up
European Society of Cardiology Scientific Congress, September 2006
Role of Stenting in Acute MI: PAMI Stent Pilot Trial
Long-term safety and efficacy of zotarolimus-eluting and sirolimus-eluting stents in routine clinical care patients 36-month follow-up in the SORT OUT.
Gregg W. Stone, MD Columbia University Medical Center
SMART-STRATEGY Trial design: Patients with a bifurcation coronary lesion were randomized to a conservative strategy (n = 128) vs. an aggressive strategy.
ENDEAVOR III Multicenter Randomized Trial Clinical/MACE Angio/IVUS
Updated 3-Year Meta-Analysis of the TAXUS Clinical Trials Safety and Efficacy Demonstrated in 3,445 Randomized Patients Time allocation for this talk.
Presented at TCT 2006.
Martin B. Leon, David R. Holmes, Dean J. Kereiakes, Jeffrey J
Maintenance of Long-Term Clinical Benefit with
DEScover: One-Year Clinical Results
TAXUS VI Randomized Trial of Moderate-Rate Release Polymer-Based Paclitaxel-Eluting TAXUS Stent for the Treatment of Longer Lesions Three Year Clinical.
MACE: Death, MI or TLR at 5 years
Sirolimus Stent vs. Bare Stent in Acute Myocardial Infarction Trial
American College of Cardiology Presented by Dr. Adnan Kastrati
The American College of Cardiology Presented by Dr. A. Abazid
NOBLE Trial design: Patients with unprotected left main disease were randomized to either PCI with a drug-eluting stent (DES) (88% biolimus) or CABG. They.
TYPHOON Trial Trial to Assess the Use of the Cypher Stent in Acute Myocardial Infarction Treated with Balloon Angioplasty (TYPHOON) Trial Presented at.
Presentation transcript:

TAXUS II and IV: two-year follow-up TAXUS II Trial TAXUS IV Trial 536 patients with single de novo lesions Lesions <12 mm in length, 3.0-3.5 mm in diameter; Double blind, randomized trial 1,326 patients with single de novo lesions Lesions 10-28 mm in length, 2.5-3.75 mm in diameter; Double blind, randomized trial Paclitaxel-eluting stent Slow-release formulation n=131 Moderate-release formulation n=135 Paclitaxel-eluting stent Slow-release formulation n=662 Bare Stent n= 270 (combined control) Bare Stent n= 652 Endpoints (2 year follow-up): TAXUS II – MACE (97% two-year clinical follow-up) – Late loss (<40% two-year angiographic follow-up) TAXUS IV – MACE – angiographic results not presented Presented at TCT 2004

TAXUS II: Late loss at 6 mo. and two yrs. Two-year angiographic results were available for < 40% of the original TAXUS cohorts, but those available showed little change in late-loss between six months and two years. p=<0.0001 p =NS p =NS mm TCT 2004

TAXUS II: MACE at two years Target lesion revascularization (TLR) and target vessel revascularization (TVR) remained significantly lower in the TAXUS groups, resulting in lower overall MACE. p=0.0178 p=0.0178 p=0.0622 p=0.0126 % p=0.0047 p=0.0006 TCT 2004

TAXUS II: MACE at two years (contin.) Despite reduced TLR and TVR in the TAXUS groups, CABG, MI, and death rates were not statistically different between the TAXUS and control groups. p=NS p=NS p=NS p=NS % TCT 2004

TAXUS IV: MACE at two years TAXUS IV showed similar two-year results: TVR, TLR, and overall MACE remained significantly lower in the TAXUS group. p =<0.0001 p=<0.0001 p =<0.0001 % TCT 2004

TAXUS IV: MACE at two years (contin.) Again, despite reduced overall MACE, rates of death and MI were not significantly different between the two groups. p =NS p=NS % TCT 2004

TAXUS II and IV: two-year follow-up Among patients with single de novo coronary lesions, treatment with a paclitaxel-eluting stent continued to be associated with a reduction in TLR and TVR at 2 years compared with bare stent Consistent with the 6 month and 1 year data, TAXUS stents were not associated with a reduction in the clinical endpoints of death or MI at 2 years. The on-going REALITY trial is a head-to-head trial comparing paclitaxel-eluting stents to sirolimus-eluting stents, which have also been associated with significant reduction in TVR (SIRIUS trial)