AC Power.

Slides:



Advertisements
Similar presentations
Since Therefore Since.
Advertisements

Each of the circuit elements will have a different ac current response to an applied ac voltage. We need to look at each of these elements. Resistor:
Chapter 15 AC Fundamentals.
Capacitor: Let us consider the following circuit consisting of an ac voltage source and a capacitor. The current has a phase shift of +  /2 relative to.
We have been using voltage sources that send out a current in a single direction called direct current (dc). Current does not have to flow continuously.
Sinusoidal Steady-State Power Calculations
Alternating Current Circuits
1 Chapter 1. Three-Phase System. 1.1: Review of Single-Phase System The Sinusoidal voltage v 1 (t) = V m sin  t i v1v1 Load AC generator v2v2 2.
Alternating Current Circuits
Faculty of Electrical Engineering Universiti Teknologi Malaysia
1 My Chapter 21 Lecture Outline. 2 Chapter 21: Alternating Currents Sinusoidal Voltages and Currents Capacitors, Resistors, and Inductors in AC Circuits.
EET 103 Chapter 3 (Lecture 1) Three Phase System.
THREE PHASE CIRCUIT.
Ch – 35 AC Circuits.
AC Fundamentals Chapter 15. Introduction 2 Alternating Current 3 Voltages of ac sources alternate in polarity and vary in magnitude Voltages produce.
Alternating Current Circuits
ELECTRICAL CIRCUIT ET 201 Define and explain characteristics of sinusoidal wave, phase relationships and phase shifting.
EE2010 Fundamentals of Electric Circuits Lecture 13 Sinusoidal sources and the concept of phasor in circuit analysis.
Chapter 7 AC Power Analysis
1 Alternating Current Circuits Chapter Inductance CapacitorResistor.
1 ELECTRICAL CIRCUIT ET 201  Become familiar with the operation of a three phase generator and the magnitude and phase relationship.  Be able to calculate.
Review 1. Review of Phasors Goal of phasor analysis is to simplify the analysis of constant frequency ac systems: v(t) = V max cos(  t +  v ), i(t)
Power System Fundamentals EE-317 Lecture 3 06 October 2010.
ELECTRICAL TECHNOLOGY EET 103/4
Fig 33-CO These large transformers are used to increase the voltage at a power plant for distribution of energy by electrical transmission to the power.
Slide 1Fig 33-CO, p Slide 2Fig 33-1, p the basic principle of the ac generator is a direct consequence of Faraday’s law of induction. When.
COVERAGE TOPICS 1. AC Fundamentals AC sinusoids AC response (reactance, impedance) Phasors and complex numbers 2. AC Analysis RL, RC, RLC circuit analysis.
EKT103 ELECTRICAL ENGINEERING
Three-Phase System 1 by Dr Rosemizi Abd Rahim Click here to watch the three phase animation video
THREE PHASE POWER Generation Transportation Consumption.
ELECTRICAL TECHNOLOGY (EET 103) PN HAZIAH ABDUL HAMID.
EKT103 ELECTRICAL ENGINEERING
1 AC Circuit Theory. 2 Sinusoidal AC Voltage Waveform: The path traced by a quantity, such as voltage, plotted as a function of some variable such as.
EKT103 ELECTRICAL ENGINEERING Chapter 1 Three-Phase System Dr. Rosemizi Abdul Rahim Dr. Amir Razif Arief Jamil Abdullah ( ) Dr. Junita Mohd Nordin.
Announcements Midterm Exam next Wednesday Exam starts at 6 PM, ~1 hr. Closed book, one page of notes Bring a calculator (not phone, computer, iPad, etc.)
1 Chapter 3 AC Power Analysis. 2 AC Power Analysis Chapter 3 3.1Instantaneous and Average Power 3.2Maximum Average Power Transfer 3.3Effective or RMS.
Copyright R. Janow – Spring 2016 Physics Electricity and Magnetism Lecture 14 - AC Circuits, Resonance Y&F Chapter 31, Sec Phasor Diagrams.
Chapter 33 Alternating Current Circuits. Electrical appliances in the house use alternating current (AC) circuits. If an AC source applies an alternating.
Physics 213 General Physics Lecture Last Meeting: Self Inductance, RL Circuits, Energy Stored Today: Finish RL Circuits and Energy Stored. Electric.
Lesson 31: Three Phase Sources and Loads
Lesson 14: Introduction to AC and Sinusoids
BASIC ELECTRICAL TECHNOLOGY Chapter 3 - Three Phase System
SYLLABUS AC Fundamentals AC Analysis AC power Three phase circuit
ELECTRICAL TECHNOLOGY EET 103/4
Sinusoidal Excitation of Circuits
Physics Electricity and Magnetism Lecture 14 - AC Circuits, Resonance Y&F Chapter 31, Sec Phasor Diagrams for Voltage and Current The Series.
PHYS 1444 – Section 501 Lecture #22
Inductance, Electromagnetic Oscillations, and AC Circuits
Three-Phase System Three phase systems Faculty of IIITN Ratnakar N.
DKT213 ELECTRICAL TECHNOLOGY
Why are the transmission lines high-voltage, three-phase and AC?
COVERAGE TOPICS AC Fundamentals AC Analysis AC power
5. Alternating Current Circuits
site.iugaza.edu.ps/ajasser
Chapter 22: AC Circuits Figure (a) Direct current. (b) Alternating current.
Alternating Current Circuits
An {image} series circuit has {image} , {image} , and {image}
Sinusoidal Waveform Phasor Method.
Electromechanical Systems
POLYPHASE CIRCUITS LEARNING GOALS Three Phase Circuits
CHAPTER 6 (BEE) AC Fundamentals
Circuits II EE221 Unit 12 Instructor: Kevin D. Donohue
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
The instantaneous power
C H A P T E R 11 A.C. Fundamentals.
Passive Elements and Phasor Diagrams
BALANCE THREE PHASE SYSTEM
Grid system is accomplished by three-phase alternating currents.
Physics 312: Electronics (1) Lecture 7 AC Current I Fundamentals of Electronics Circuits (with CD-ROH) By: Charles Alexander, Hathew Sadika, McGraw Hill.
Presentation transcript:

AC Power

AC Power As in the case with DC power, the instantaneous electric power in an AC circuit is given by P = VI, but these quantities are continuously varying. Almost always the desired power in an AC circuit is the average power, which is given by Pavg = V I cos  where  is the phase angle between the current and the voltage and V and I are understood to be the effective or rms values of the voltage and current. The term cos    is called the "power factor" for the circuit.

Instantaneous Power As in DC circuits, the instantaneous electric power in an AC circuit is given by P=VI where V and I are the instantaneous voltage and current. Since then the instantaneous power at any time t can be expressed as

Average Power the power becomes: Averaging this power over a complete cycle gives the average power. Average Power                                                   Normally the average power is the power of interest in AC circuits. Since the expression for the instantaneous power is a continuously varying one with time, the average must be obtained by integration. Averaging over one period T of the sinusoidal function will give the average power. The second term in the power expression above averages to zero since it is an odd function of t. The average of the first term is given by

Since the rms voltage and current are given by                and the average power can be expressed as                       

Average Power Integral Finding the value of the average power for sinusoidal voltages involves the integral                                                                                                     The period T of the sinusoid is related to the angular frequency   and angle   by                                                        Using these relationships, the integral above can be recast in the form: Which can be shown using the trig identity:                                                which reduces the integral to the value 1/2 since the second term on the right has an integral of zero over the full period.

RLC Series Circuit The RLC series circuit is a very important example of a resonant circuit. It has a minimum of impedance Z=R at the resonant frequency, and the phase angle is equal to zero at resonance.

Vm = the amplitude of the sinusoid Single-phase System The Sinusoidal voltage v(t) = Vm sin wt where Vm = the amplitude of the sinusoid w = the angular frequency in radian/s t = time

The angular frequency in radians per second

Single-phase System v(t) = Vm sin (wt + q) where q is the phase angle A more general expression for the sinusoid (as shown in the figure): v(t) = Vm sin (wt + q) where q is the phase angle

Single-phase System sin (ωt ± 180o) = - sin ωt A sinusoid can be expressed in either sine or cosine form. When comparing two sinusoids, it is expedient to express both as either sine or cosine with positive amplitudes. We can transform a sinusoid from sine to cosine form or vice versa using this relationship: sin (ωt ± 180o) = - sin ωt cos (ωt ± 180o) = - cos ωt sin (ωt ± 90o) = ± cos ωt cos (ωt ± 90o) = + sin ωt

Single-phase System Apparent Power, Reactive Power and Power Factor The apparent power is the product of the rms values of voltage and current. The reactive power is a measure of the energy exchange between the source and the load reactive part.

Single-phase System The power factor is the cosine of the phase difference between voltage and current. The complex power:

Three-phase System

Generation of Three-phase In a three phase system the source consists of three sinusoidal voltages. For a balanced source, the three sources have equal magnitudes and are phase displaced from one another by 120 electrical degrees. A three-phase system is superior economically and advantage, and for an operating of view, to a single-phase system. In a balanced three phase system the power delivered to the load is constant at all times, whereas in a single-phase system the power pulsates with time.

Generation of Three-phase Suppose three similar loops of wire with terminals R-R’, Y-Y’ and B-B’ are fixed to one another at angles of 120o and rotating in a magnetic field.

Generation of Three-phase The instantaneous e.m.f. generated in phase R, Y and B: vR = VR sin wt vY = VY sin (wt -120o) vB = VB sin (wt -240o) = VBsin (wt +120o)

Generation of Three-phase Phase sequences: RYB or positive sequence VR leads VY, which in turn leads VB This sequence is produced when the rotor rotates in the counterclockwise direction

Generation of Three-phase (b) RBY or negative sequence VR leads VB, which in turn leads VY This sequence is produced when the rotor rotates in the clockwise direction

Star and Delta Connection

Star Connection Three wire system

Four wire system

Wye connection of Load

Delta Connection

Delta connection of load

Wye Connection Line-to-neutral voltages: # Reference: VRN # Positive sequence

The two other can be calculated similarly.

The line to line voltages

Line-to-line currents: Delta Connection Line-to-line currents: # Reference: IRY # Positive sequence.

The two other can be calculated similarly.

The line currents:

Vector diagram Phasor diagram is used to visualize the system voltages • Wye system has two type of voltages: Line-to-neutral, and line-to-line • The line-to-neutral voltages are shifted with 120 degrees • The line-to-line voltage leads the line to neutral voltage with 30 degrees • The line-to-line voltage is times the line-to-neutral voltage

TNB SUPPLY SYSTEM Voltage 3 phase, 50 Hz The main transmission and substation network are: - 275 kV - 132 kV - 66 kV The distribution are: - 33 kV - 22 kV - 11 kV - 6.6 kV - 415 volts - 240 volts (single phase) drawn from 415 volts 3 phase (phase voltage), between line (R, Y, B) and Neutral (N)

Supply Method (two types of premises) SYSTEM The low voltage system (415/240 V) is 3-phase four wire. The low voltage system is a mixture of overhead lines and under ground cables. The high voltage and extra high voltage system is 3-phase three wire Configuration. Overhead line and under ground cable system are used. Supply Method (two types of premises) 1. Single consumer such as private dwelling house, workshop, factory, etc Single phase, two wire, 240 V, up to 12 kVA max demand Three phase, four wire, 415 V, up to 45 kVA max demand Three phase, four wire, C. T. metered 415 V, up to 1,500 kVA max demand

High Voltage and Extra High Voltage 2. Multi tenanted premises, such as high rises flats, commercial, office blocks, etc Low Voltage Three phase, four wire, C.T. metered 415 V, up to 1,500 kVA max demand High Voltage and Extra High Voltage Three phase, three wires, 6,600 and 11,000 V for load of 1, 500 kVA max demand and above, whichever voltage is available Three phase, three wires, 22,000 and 33,000 V for load of 5,000 kVA Three phase, three wires, 66,000 V, 132,000 V and 275,000 for exceptionally large load of above 20 MVA max demand

Standby Supply Standby generator(s) to be used by the consumer in his premises, in accordance with the relevant by-laws, may be provided by the consumer The generator(s) shall remain a separate system from the TNB’s Distribution system and should be certified and registered by Suruhanjaya Tenaga (formerly JBE) This may be used in place of the TNB’s supply source through a suitable, Approved change over facility under emergency conditions.

Berubah setiap masa, hari, minggu dan bulan. Beban Berubah setiap masa, hari, minggu dan bulan. Beban mempengaruhi penjanaan tenaga. Penjanaan tenaga berdasarkan permintaan beban yang lepas. Lengkuk beban berubah dalam sehari.