Risk Management with Minimum Weight

Slides:



Advertisements
Similar presentations
Measurements: Accuracy, Precision, & Error
Advertisements

1 Seventh Lecture Error Analysis Instrumentation and Product Testing.
Key changes and transition process
Topic 11: Measurement and Data Processing
Introduction to ISO New and modified requirements.
Chapter 2 Data Handling.
INTRODUCTION TO MEASUREMENT
Accuracy, Precision, and Error
Measurement and Its Uncertainties.
Calculating Uncertainties
Metrology Adapted from Introduction to Metrology from the Madison Area Technical College, Biotechnology Project (Lisa Seidman)
Topic 11.  The material in this topic is tested any time you do a lab or calculation.  It is extremely important that you follow the rules explained.
1 / 24 Introduction Eccentricity effects INTI Buenos Aires Oliver Mack: Recommendation For The Revision Of Test Procedures For Load Cells In Legal Metrology.
Case Study 1. References Provides full details of sources of information Author. (YEAR). Title. Place of Publishing. Publisher. Lave, J. (1988) Cognition.
Uncertainty and Error in Measurement (IB text - Ch 11) (If reviewing this slide in the senior year, there is also uncertainty information in the AP text.
1 CURRENT PRACTICES AND FUTURE CHALLENGES IN METHODS VALIDATION – NEW AREAS OF APPLICATION THE POINT OF VIEW OF AN ACCREDITATION BODY EURACHEM Workshop.
3.1 Using and Expressing Measurements > 1 Copyright © Pearson Education, Inc., or its affiliates. All Rights Reserved. Chapter 3 Scientific Measurement.
Experimental Errors & Uncertainty. Objectives Define precision, accuracy. Understand sources of uncertainty where they come from. Understand sources of.
Author: Nurul Azyyati Sabri
Scientific Notation Do you know this number? m/sec
Topic 1: Measurement and uncertainties 1.2 Uncertainties and errors
MECH 373 Instrumentation and Measurement
Actuaries Climate Index™
Measurement: Accuracy, Precision, & Error
Learn Your Information Security Management System
Weighbridge Training Course Beijing - September 2017
Making Measurements and Using Numbers
Calculating Uncertainties
Instrument Maintenance
Prepared by Rand E Winters, Jr. ASR Senior Auditor October 2014
Teacher’s Notes This sequence of slides is designed to introduce, and explain the taking of measurements, including the meaning of variation, range, mean.
Calibration of Weighing Instruments
Fundamentals of ISO.
Accuracy and Precision
INTRODUCTION TO ISO 9001:2015 FOR IMPLEMENTATION Varinder Kumar CISA, ISO27001 LA, ISO 9001 LA, ITIL, CEH, MEPGP IT, Certificate course in PII & Privacy.
ISO 9001:2015 Auditor / Registration Decision Lessons Learned
2005 MRG stakeholder day Concerns and proposals of the downstream oil industry J-F. Larivé, CONCAWE.
HIGHLIGHTING THE KEY CHANGES
Actuaries Climate Index™
Accuracy and Precision
Chapter 3 Scientific Measurement 3.1 Using and Expressing Measurements
Errors and Uncertainties
Measurements and Sig Figs
Significant Figures The significant figures of a (measured or calculated) quantity are the meaningful digits in it. There are conventions which you should.
Introduction to Significant Figures &
ERT 207 Analytical Chemistry
Measurements and Their Uncertainty 3.1
Measurements and Their Uncertainty
Lesson 1: Summarizing and Interpreting Data
The Standard Normal Distribution
Errors and Uncertainties
Measurement book reference p
Please take a notes packet and put your name on it.
Introduction Previous lessons have demonstrated that the normal distribution provides a useful model for many situations in business and industry, as.
Measurement Unit Unit Description:
Estimating a Population Mean:  Known
Risky Business Standalone ISO9001:2015 Risk-Based Thinking and Integration of Risk Management with ISO9001:2015.
ISO 9001:2008 Quality Management Systems
Chapter # 8 Quality Management Standards
How to conduct Effective Stage-1 Audit
3.1A Measurements and Their Uncertainty
Stewardship in biotechnology
Solving Absolute Value Inequalities
Introduction to Measurement
Using Scientific Measurements
8.3 Estimating a Population Mean
Introduction to Chemistry and Measurement
Nonconformity Writing
Presentation transcript:

Risk Management with Minimum Weight Conference Centre, Centurion August 1st Denis LOUVEL, MT-SI denis.louvel@mt.com Risk Management with Minimum Weight

Agenda 1 Introduction 2 Reading, Rounding and Relative error 3 Weighing Range 4 Minimum Weight, MW 5 Safety Factor, SF 6 Safe Weighing Range, SWR 7 GWP Verification® 8 ISO 9001:2015 9 To shift Highlight Click the arrow, press shift key and move top or bottom For internal use - Confidential

Introduction Many companies may be unaware that their weighing instruments do not meet their process accuracy requirements. An analysis of weighing instruments is imperative in providing data which can be used to minimize non conformity related to accuracy.

Agenda 1 Introduction 2 Reading, Rounding and Relative error 3 Weighing Range 4 Minimum Weight, MW 5 Safety Factor, SF 6 Safe Weighing Range, SWR 7 GWP Verification® 8 ISO 9001:2015 9 To shift Highlight Click the arrow, press shift key and move top or bottom For internal use - Confidential

Reading, Rounding and Relative error All balances generate a risk during weighing This phenomenon is not limited to balances It occurs for all instruments having a digital display (e.g. a voltmeter, a thermometer, a speed meter, etc.) The weight measured by the balance is not the weight displayed by the balance Amazing but true!! Let me explain to understand this risk with a closer look to the balance digital display

Reading, Rounding and Relative error What you see is NOT what you get To each weight displayed corresponds a set of measured weights limited by 2 changeover points (yellow circles). This set of values generates an ambiguity during the conformity assessment of a weighed product. The range of the measured weights before rounding (e.g. 2000.5 g – 1999.5 g = 1 g ; 2001.5 g – 2000.5 g = 1 g) corresponds to the balance readability d. The official name for d is "actual scale interval".

Reading, Rounding and Relative error The relative error depends on the displayed mass With a displayed weight of 2000 g, the relative error is then: With a displayed weight of 200 g, the relative error is then: With a displayed weight of 20 g, the relative error is then:

Reading, Rounding and Relative error We can plot the relative error E%, (ratio between d and the displayed weight, m) The relative error becomes increasingly larger as the load approaches zero.

Reading, Rounding and Relative error If the user wants to guarantee a weighing of 0.5 %, the minimum weight with this balance will be 200 g (red dotted lines).

Agenda 1 Introduction 2 Reading, Rounding and Relative error 3 Weighing Range 4 Minimum Weight, MW 5 Safety Factor, SF 6 Safe Weighing Range, SWR 7 GWP Verification® 8 ISO 9001:2015 9 To shift Highlight Click the arrow, press shift key and move top or bottom For internal use - Confidential

Weighing Range Red or Green With a relative error of 0.5%: Below 200 g (red area) the weighing is not safe Above 200 g (green area) the weighing is safe WEIGHING RANGE

Agenda 1 Introduction 2 Reading, Rounding and Relative error 3 Weighing Range 4 Minimum Weight, MW 5 Safety Factor, SF 6 Safe Weighing Range, SWR 7 GWP Verification® 8 ISO 9001:2015 9 To shift Highlight Click the arrow, press shift key and move top or bottom For internal use - Confidential

Minimum Weight, MW Simple calculation The definition of the minimum weight is based on the same formula but few changes are necessary. with: d, is the actual scale interval Acceptance limit is the relative error (E%) as percentage replaced by the acceptance limit (always defined by the user) The weight displayed m becomes the minimum weight “MW ”

Minimum Weight, MW A better definition for MW As the actual scale interval, d, doesn't show the quality of a measurement, it is better to replace d by the balance uncertainty U. This leads to a minor change in the formula. d is replaced by the balance uncertainty U MW is still the Minimum weight The Acceptance Limit, in percentage, is always defined by the user A last improvement is necessary. It consists to account the Safety Factor defined by the user.

Agenda 1 Introduction 2 Reading, Rounding and Relative error 3 Weighing Range 4 Minimum Weight, MW 5 Safety Factor, SF 6 Safe Weighing Range, SWR 7 GWP Verification® 8 ISO 9001:2015 9 To shift Highlight Click the arrow, press shift key and move top or bottom For internal use - Confidential

Safety Factor, SF The safety factor accounts for: changes during working conditions different people working with the instruments historical data of the weighing instrument verification therefore and not to be forgotten, economic factors changes that could affect measurement in daily routine use A safety factor equal to 1 reflects the balance uncertainty only at the point and time when it was last calibrated with standards weights. In the worst case, it can happen that the temperature vary right after the calibration, thus leading to an increase of the measurement uncertainty and consequently out-of- specifications results. Therefore a safety factor >1 adds safety to the manufacturing process. Typically a safety factor between 2 and 5 is recommended.

Safety Factor, SF The user decides what factor to apply. If the weighing is critical, a safety > 2 is necessary. Today, no tables are available to define a safety factor. As a general rule of thumb, within an industrial context, a safety factor of at least 2 is always suggested – even if everything appears to be under control.

Agenda 1 Introduction 2 Reading, Rounding and Relative error 3 Weighing Range 4 Minimum Weight, MW 5 Safety Factor, SF 6 Safe Weighing Range, SWR 7 GWP Verification® 8 ISO 9001:2015 9 To shift Highlight Click the arrow, press shift key and move top or bottom For internal use - Confidential

Safe Weighing Range, SWR Red, Orange and Green like traffic lights The safety factor improves the weighing: In the red area, the weighing is not safe In the orange area, the weighing is safe, but the safety factor is not fulfilled In the green area, the weighing is fully safe SAFE WEIGHING RANGE

Agenda 1 Introduction 2 Reading, Rounding and Relative error 3 Weighing Range 4 Minimum Weight, MW 5 Safety Factor, SF 6 Safe Weighing Range, SWR 7 GWP Verification® 8 ISO 9001:2015 9 To shift Highlight Click the arrow, press shift key and move top or bottom For internal use - Confidential

GWP Verification® A scientific approach to assess a process With GWP® (GWP = Good Weighing Practice), the METTLER TOLEDO service, you can assess the risk GWP Verification® consists to establish the link between the balance performance (its uncertainty) and the acceptance limits defined by the user. GWP Verification® applies to all models and brands of weighing instruments and to all balances in the production field.

GWP® Life Cycle Management GWP®, the science-based standard for efficient life-cycle management of weighing equipment. GWP® gives clear answers how to specify and calibrate balances and scales – covering every relevant step in the equipment's life cycle. GWP is the global weighing guideline for managing of weighing instruments. It helps the user get accurate results at all times and guides them in five simple steps, following the life cycle of the instrument. In each of these important 5 steps, GWP helps the user make the right decisions. ->>>> Allow me to highlight each of these 5 steps briefly in the subsequent slides. 33

Certifies the accuracy of the scale for the weighing process GWP® Verification Certifies the accuracy of the scale for the weighing process For every instrument Documents whether the accuracy of the scale, based on minimum weight and safety factor, satisfies the process requirements Sample Determines the minimum weight based on the calibration of the scale

GWP® Verification Analysis of the scales and their accuracy in the process Recommendations for measuring equipment monitoring based on risk analysis Complete documentation Overview of the status of all scales Training

Agenda 1 Introduction 2 Reading, Rounding and Relative error 3 Weighing Range 4 Minimum Weight, MW 5 Safety Factor, SF 6 Safe Weighing Range, SWR 7 GWP Verification® 8 ISO 9001:2015 9 To shift Highlight Click the arrow, press shift key and move top or bottom For internal use - Confidential

ISO 9001:2015 and Weighing GWP complies with Risk-based thinking One of the key changes in the 2015 revision of ISO 9001 is a focus on risk-based thinking. Whilst risk-based thinking has always been a part of ISO 9001, the 2015 version gives it increased prominence by building it into the whole management system. In previous editions of ISO 9001, a clause on preventive action was separated from the whole. The aim is to establish a systematic approach to considering risk, rather than treating “prevention” as a separate component of a quality management system. Risk-based thinking is part of the process approach. ISO 9001:2015 0.3.3 Risk-based thinking Risk-based thinking is essential for achieving an effective quality management system. […] To conform to the requirements […] an organization needs to plan and implement actions to address risks and opportunities. For internal use - Confidential

Thank you for your attention Visit us to see our GWP solutions for Risk Management