Midterm Exam One-week take-home exam, to cover material of HW#1-6 Averaged switch modeling Simulation Extra element theorem Input filter design N-extra element theorem Feedback theorem DCM modeling On-campus: handed out this Friday March 6, due at beginning of class of Friday March 13 Off-campus: start exam at time of your choosing, after you at least have completed HW#6.
Sampling v*(t) v(t) T Sampler v(t) t v*(t) t Unit impulse (Dirac)
Unit impulse Properties t Laplace transform unit step d(t) area = 1
Sampling in frequency domain
Sampling in frequency domain: derivation
Sampling in frequency domain: derivation
Aliasing
Zero-order hold H v*(t) vo(t) v*(t) t vo(t) t Zero-order hold nT T = sampling period 1/T = sampling frequency
Zero-order hold: time domain vo(t) Zero-order hold
Zero-order hold: frequency domain u(t) vo(t) Zero-order hold
Sampled-data system example: frequency domain v*(t) H v(t) vo(t) T Sampler Zero-order hold Consider only low-frequency signals: System “transfer function” =
Zero-order hold: frequency responses
Zero-order hold: frequency responses fs = 1 MHz MATLAB file: zohfr.m
Zero-order hold: 1st-order approximation 1st-order Pade approximation
Zero-order hold: frequency responses fs = 1 MHz MATLAB file: zohfr.m
How does any of this apply to converter modeling?
PWM is a small-signal sampler! PWM sampling occurs at tp (i.e. at dTs, periodically, in each switching period)
General sampled-data model Sampled-data model valid at all frequencies Equivalent hold describes the converter small-signal response to the sampled duty-cycle perturbations [Billy Lau, PESC 1986] State-space averaging or averaged-switch models are low-frequency continuous-time approximations to this sampled-data model
Application to DCM high-frequency modeling iL c dTs d2Ts Ts
Application to DCM high-frequency modeling iL c dTs d2Ts Ts
DCM inductor current high-frequency response High-frequency pole due to the inductor current dynamics in DCM, see (11.77) in Section 11.3
Conclusions PWM is a small-signal sampler Switching converter is a sampled-data system Duty-cycle perturbations act as a string of impulses Converter response to the duty-cycle perturbations can be modeled as an equivalent hold Averaged small-signal models are low-frequency approximations to the equivalent hold In DCM, at high frequencies, the inductor-current dynamic response is described by an equivalent hold that behaves as zero-order hold of length D2Ts Approximate continuous-time model based on the DCM sampled-data model correlates with the analysis of Section 11.3: the same high-frequency pole at fs/(pD2) is obtained Next: current-mode control (Chapter 12)