Noise Analysis for PREx - Pb Radius Experiment

Slides:



Advertisements
Similar presentations
PREX PAC 29 Jan 2006 R. Michaels Jefferson Lab Lead ( Pb) Radius Experiment : PREX Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons ( T.W.
Advertisements

R. Michaels PREX at HE06 July 2006 Lead ( Pb) Radius Experiment : PREX Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons ( T.W. Donnelly,
Robert Michaels PREX at Trento PREX Workshop 09 Physics Interpretation of PREX 208 Pb E = 1 GeV, electrons on lead Elastic Scattering Parity Violating.
Compton integrating method Beam test summary PREX/Happex Collaboration Meeting Alexandre Camsonne.
Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : precise measurement of the density -dependence.
Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : density -dependence of the symmetry energy. Nuclear.
BigBite K.Egiyan Probabilities of SRC in Nuclei Measured with A(e,e / ) Reactions K. Egiyan (Yerevan Physics Institute, Yerevan, Armenia and Jefferson.
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky for the JLab Hall A Collaboration College of William and Mary, Williamsburg VA.
Lumi Analysis for HAPPEx III / PREX Presented by: Luis Mercado UMass - Amherst 5/18/2007.
1 Experimental Nuclear Physics at UMass UMass, February 1st, 2010.
Lead ( Pb) Radius Experiment : PREX Pb E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons Paul Souder Krishna.
The neutron radius of 208 Pb and neutron star structure. guitar nebula, neutron star bow wave.
Noise Analysis for PREx - Pb Radius Experiment Presented by: Luis Mercado UMass - Amherst 6/20/2008.
The Strange Form Factors of the Proton and the G 0 Experiment Jeff Martin University of Winnipeg Collaborating Institutions Caltech, Carnegie-Mellon, William&Mary,
Recent Electroweak Results from the Tevatron Weak Interactions and Neutrinos Workshop Delphi, Greece, 6-11 June, 2005 Dhiman Chakraborty Northern Illinois.
Parity Violation in Electron Scattering Emlyn Hughes SLAC DOE Review June 2, 2004 *SLAC E122 *SLAC E158 *FUTURE.
PN12 Workshop JLab, Nov 2004 R. Michaels Jefferson Lab Parity Violating Neutron Densities Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons.
PREX PAVI06 May 2006 R. Michaels Jefferson Lab Lead ( Pb) Radius Experiment : PREX Z of Weak Interaction : Clean Probe Couples Mainly to Neutrons ( T.W.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Does a nucleon appears different when inside a nucleus ? Patricia Solvignon Argonne National Laboratory Postdoctoral Research Symposium September 11-12,
Measurements of F 2 and R=σ L /σ T on Deuteron and Nuclei in the Nucleon Resonance Region Ya Li January 31, 2009 Jlab E02-109/E (Jan05)
Opportunities for Precision Measurements, New Physics Searches & Low Energy Fixed Target Expts at a Modified “FEL” Accelerator Complex R. D. Carlini 12/7/2011.
Nuruzzaman ( Hampton University Group Meeting 1 st November 2011 Beamline Optics Using Beam Modulation for the Q-weak Experiment.
Z coll =590cm z targ,up =-75cm z targ,center =0cm z targ,down =75cm θ low =5.5mrad θ high =17mrad R inner =3.658cm R outer =11.306cm From center:From downstream:
Crystal Ball Collaboration Meeting, Mainz, October 2007 Claire Tarbert, Univeristy of Edinburgh Coherent  0 Photoproduction on Nuclei Claire Tarbert,
Isospin mixing and parity- violating electron scattering O. Moreno, P. Sarriguren, E. Moya de Guerra and J. M. Udías (IEM-CSIC Madrid and UCM Madrid) T.
Pygmy Dipole Resonance in 64Fe
Pb Electroweak Asymmetry in Elastic Electron-Nucleus Scattering -- Weak charge form factor -- most weak charge is carried by neutrons PREX and.
Presentation by T. Gogami 2015/6/15 (Mon). Equation state of neutron matter.
Pb Electroweak Asymmetry in Elastic Electron-Nucleus Scattering : A measure of the neutron distribution PREX and CREX 48 Ca Neutron Skin Horowitz.
May 17, 2006Sebastian Baunack, PAVI06 The Parity Violation A4 Experiment at forward and backward angles Strange Form Factors The Mainz A4 Experiment Result.
Neutral Current Deep Inelastic Scattering in ZEUS The HERA collider NC Deep Inelastic Scattering at HERA The ZEUS detector Neutral current cross section.
Jin Huang M.I.T. For Transversity Collaboration Meeting Mar 26, JLab.
Coulomb distortions in the Lead Radius Experiment (PREX) Tim Cooper (Univ. College Fraser Valley) C. J. Horowitz (Indiana)
HAPPEX DAQ / ADC Tests Luis Mercado UMASS 4/17/09.
PREX Issues. Outline New issue: souce systematics and Aug. 07 run. Update on old issues. Progress at SU.
Moller Polarimeter Q-weak: First direct measurement of the weak charge of the proton Nuruzzaman (
R. Michaels PREX at PAVI 09 Lead ( Pb) Radius Experiment : PREX Pb E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.
Absolute Polarization Measurement at RHIC in the Coulomb Nuclear Interference Region September 30, 2006 RHIC Spin Collaboration Meeting RIKEN, Wako, Japan.
HAPPEX/Lumi PMT Studies Luis Mercado UMASS 7/10/09.
Comparison of MC and data Abelardo Moralejo Padova.
H. Matis, S. Hedges, M. Placidi, A. Ratti, W. Turner [+several students] (LBNL) R. Miyamoto (now at ESSS) H. Matis - LARP CM18 - May 8, Fluka Modeling.
John Leacock April 20, 2009 Qweak: A Precision Test of Standard Model and Determination of Weak Charge of the Proton Four fundamental interactions of the.
LUIS MERCADO UMASS 7/10/09 HAPPEX DAQ / 18-bit ADCs.
Hall A Collab. Mtg, 6/ 2010R. Michaels, JLAB Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, Elastic Scattering Parity-Violating Asymmetry PREX : precise.
Understanding the 3 He Nuclei: Asymmetry Measurements in Quasi- Elastic Ge Jin University of Virginia For the E Collaboration.
Pb-Parity and Septum Update Presented by: Luis Mercado UMass - Amherst 12/05/2008 Thanks to Robert Michaels, Kent Pachke, Krishna Kumar, Dustin McNulty.
Electric Dipole Response, Neutron Skin, and Symmetry Energy
PV Electron Scattering
Radiative Corrections to PREX and QWEAK
Sanghwa Park (Stony Brook) for the PREX/CREX Collaboration
Kellogg Radiation Lab, Caltech Pasadena, CA
Charged Current Cross Sections with polarised lepton beam at ZEUS
Weak probe of the nucleon in electron scattering
The G0 experiment at JLAB
Hall A Collaboration Meeting
Instrumentation for Colliding Beam Physics 2017
G0 Accelerator Planning Meeting (11/1/05)
LEDA / Lepton Scattering on Hadrons
Precision Measurement of η Radiative Decay Width via Primakoff Effect
Deep Inelastic Parity Robert Michaels, JLab Electroweak Physics
Lead ( Pb) Radius Experiment : PREX
LEDA / Lepton Scattering on Hadrons
Physics Interpretation of PREX
PREX / CREX Collaboration Meeting and Status
Charged Current Cross Sections with polarised lepton beam at ZEUS
Parity – Violating Neutron Density Measurements : PREX, C-REX
IR/MDI requirements for the EIC
Measurement of Parity-Violation in the N→△ Transition During Qweak
Presentation transcript:

Noise Analysis for PREx - Pb Radius Experiment Presented by: Luis Mercado UMass - Amherst 6/20/2008

Overview Part I: About the experiment Part II: My current work Introduction – What is PREX? Motivation / Physics Background Applications in nuclear and astrophysics. Part II: My current work Luminosity Monitors Recent Results Looking Forward

PART I About the Experiment…

Introduction – What is PREx? PREx is a Parity Violation experiment to be conducted in Hall A in 2010. Will measure PV electroweak asymmetry in elastic scattering of polarized electrons from 208Lead.

Motivation (T.W. Donnelly, J. Duback, I. Sick). Because the Z boson couples mainly to neutrons, ALR can provide a clean measurement of Rn by studying the ratio of proton and neutron form factors. Proton form factor is well known, so we can extract the neutron density distribution from the neutron form factor. The value of Rn is currently known to 5% accuracy. PREx aims to achieve an accuracy of 1% or less. (C. J. Horowitz)

Physics Background Heavy nuclei such as 208Pb are believe to have a larger neutron-weak radius than its proton-charge radius. This “neutron skin” is a result of a large neutron excess and a large Coulomb barrier. Finding Rn will be a fundamental test of nuclear theory and provide clues about neutron-rich matter. (C. J. Horowitz)

Heavy Nuclei and Neutron Stars The 208Pb nucleus is 18 orders smaller and 55 orders lighter than a neutron star. Rn -> Sv -> E(np/nn) -> Pressure Lead’s neutron skin is similar to the crust of a neutron star, made up of neutron-rich matter at similar densities. To understand these systems, the equation of state of dense matter is essential. Transition density between crust and outer core depends on the neutron skin of 208Pb.

PART II My current work…

Luminosity Monitor Setup Used as diagnostic for experimental setup (beam-line, instrumentation and target). Located 7m from the target. Consists of eight symmetrically placed detectors.

Luminosity Monitor Setup

Reason for Analysis Lumis are sensitive to very small scattering angles (~0.5°), where any measured asymmetries should go to zero. Width of integrated signal gives an idea of the intrinsic noise of the experimental setup. Want noise to be < 100ppm. Noise is defined as width of asymmetry distribution for 15Hz pulse pair.

January ’08 Test Run Had week long test period for diagnosing several components of the experiment. Used several beam energies/currents on Carbon and Lead targets. Tested target stability up to 100uA successfully. New Lumi design was made to include a filter box. Some of the goals were to study backgrounds, diagnose noise and understand linearity of Lumi setup (PMTs and ADCs).

Test Run Configuration 1 1, 3, 5 & 7 see full signal. 2 & 6 have 10% filters. 4 & 8 were ‘blinded’ with aluminum sheets. Bottom three were shielded by Lead bricks. 8 2 7 3 6 4 5

Analysis of ’08 Run #10296 Data acquired on 01/25/08 with beam current of 60uA on a Thin Lead target. RMS values are regressed with respect to position and current. Lumi ID Reg. RMS [ppm] 1 119.1 2 270.2 3 112.4 4 816.3 5 105.7 6 152 7 8 383.6

1 ’08 RMS Values I (odd) 7 3 5 1 3 5 7

8 2 ’08 RMS Values II (even) 6 4 2 4 6 8

’08 Combo Noise V D1 C Sum H D2 X Ave

Analysis of ’08 Run (cont.) V D2 D1 Analysis of ’08 Run (cont.) H Statistics for 4-Lumi combo is ~50 ppm For each odd-numbered Lumi, noise should be ~100 ppm, but we get higher value. When averaging Lumis, width does not scale like 1/sqrt(N). Lumi ID Reg. RMS [ppm] V 55.7 H 62.8 D1 149.6 D2 451.2 C 51.7 X 241.1 Sum 126.7 Ave 126.3

What are the source of noise? Blinded – Backgrounds. Electronics noise in BPM and BCM. Unaccounted Beam Noise. PMT pedestals. Correlated noise. Possible Higher order effects.

Summary Lumi data is very useful for studying noise. Seems like we will be able to achieve required noise levels. Can try to reduce it further by over-sampling or by using a thicker target. Problem: thicker target introduces nonlinearities in PMTs and ADCs. Need further tests and analysis.

Acknowledgements Robert Michaels (JLab) Kent Pachke (UVA) Krishna Kumar (UMASS) Dustin McNulty (UMASS) Charles Horowitz (IU-Bloomington) The rest of the HAPPEx/PREx Collaboration…