Extraction Procedure (2)

Slides:



Advertisements
Similar presentations
Chem. 231 – 3/4 Lecture. Announcements I Set 1 Lab Reports –Both Lab Reports due 3/13 –Only one of the lab reports needs to be detailed, the other can.
Advertisements

For Large Scale Purification
Advantages to Automating the 1664 Method Joe Boyd March 28, 2012.
InfraCal TOG/TPH Analyzers for Oil and Grease Measurements
Week 3 Collection and Analysis of Biodiesel
Brian Cornwell Jason Freischlag Longwood University CHEM 351 Starlight Lane Tire Fire Superfund Site Roanoke, VA 04/26/13.
Validation of Microbiological Methods for Use in the Food Industry Brazilian Association for Food Protection 6 th International Symposium Sao Paulo, Brazil.
Introducing the LabFit AS-3000 Series Automated pH Analyzers Labfit Pty Ltd 102 Goodwood Parade PO Box 343 Burswood, Western Australia 6100 Tel +(618)
Launching MIURA sample prep system
Development of an Automated, Pyridine Free Method for Aerosol Cyanide Compounds and Hydrogen Cyanide. An Alternative to NIOSH LeRoy Dobson, Chemist.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
.
US Army Engineer Research & Development Center One Team, One ERDC... Relevant, Ready, Responsive, Reliable Field Portable GC-MS Instrument for Analysis.
Laboratory requirements Dioxin Workshop, Leon Mexico Richard Turle Analysis and Air Quality Division Environmental Science and Technology Centre Environment.
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
Real-time PCR automated solution for food pathogen testing
Prabh Jassal SUPA Che113 Forensics Ms. Tolentino.
Chromatography Dr.Tawfeq A. Al-Howiriny Associate Professor
The determination of lead by MD-HG-AFS in APMP*-QM-P3 comparison Lu Xiaohua, Lu Hai, Ma Liandi, Cui Yanjie National Research Center for Certified Reference.
Workflow Diagram for the Natural Product/Metabolite/Discovery Chemist LC vacuum centrifuge MS DAD/ELSD or bioactivity NMR Purification Fraction Collection.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
A Single Calibration for Waters and Soil Samples Performing EPA Method 8260 Anne Jurek – Applications Chemist.
Ultra-Trace PCB Sampling
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
COLUMN CHROMATOGRAPHIC PURIFICATION OF NITROANILINES
Experiment 5: COLUMN CHROMATOGRAPHIC PURIFICATION OF NITROANILINES.
Lecture 12 Chromatography Introduction Ch 7: Thin-Layer Chromatography Lecture Problem 4 Due This Week In Lab: Ch 6: Procedures 2 & 3 Due: Ch 5 Final Report.
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
COLUMN CHROMATOGRAPHIC PURIFICATION OF NITROANILINES
Polybrominated diphenyl ethers by HRGC/HRMS Coreen Hamilton Brian Fowler Louis Haviland Axys Analytical Services, Ltd.
Application of Method 1668A to the Analysis of Dioxin-Like PCBs and Total PCBs in Human Tissue and Environmental Samples Coreen Hamilton, Todd Fisher,
Challenges of Conducting Analytical Chemistry in Environmental Matrices May 8 th 2006 Meg Sedlak and Don Yee San Francisco Estuary Institute Oakland, California.
From the Seed Sample to DNA II: DNA Isolation, Quantification, & Normalization Beni Kaufman.
HPLC – High Performance Liquid Chromatography
Experiment 2 DISTILLATION AND GAS CHROMATOGRAPHY OF ALKANES.
Chapter 29 Supercritical Fluid Chromatography and Extraction.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
The world leader in serving science Transmission Techniques Liquids.
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Aroclor Analysis and the Challenge of Matrix Interference “Using a Holistic approach in the Laboratory to analyze uncommon matrices with Confidence and.
Large Volume Parental (LVP) Application Biopharmaceutical Application
Marco Iammarino, Aurelia Di Taranto, Carmen Palermo*, Diego Centonze*
LU 3: Separation Technique (P2)
20l of whole blood + 80 l of water +80 l of 0.1M ZnSO4
% € $ Multiresidue analysis of 25 pesticide residues in wines
LAL: Choice of Test Method
Alltesta HPLC Analyzer Analysis of Pesticides, Dyes, and Drugs
LU 3: Separation Techniques
Introduction to Basic Clinical Chemistry
Automation of Solid Phase Extraction Column Chromatographic Cleanup
Automation of Sample Preparation for Trace Analysis Haibin Wan
Creative Filtration and Chromatography Products
Chem. 31 – 11/1 Lecture.
GC-TRIPLE QUADRUPOLE MASS SPECTROMETRY MS/MS vs GC-HRMS FOR THE ANALYSIS OF POLYCHLORINATED DIOXINS AND FURANS UNIVERSITY OF MURCIA Agricultural Chemistry.
Determination of carbamate residues in high-fat cheeses by ultra-high performance liquid chromatography–tandem mass spectrometry using zirconia-based QuEChERS.
Solid Phase Extraction Optimization Experiment
Extraction Procedure (2)
Supercritical Fluid Chromatography and Extraction
Extraction Procedure (2)
CLEANING VALIDATION FOOD & BEVERAGE –– WASTEWATER –– LABORATORY –– PHARMACEUTICAL & MEDICAL DEVICE.
EPA method 521 by direct-inject LC-MS/MS
Extraction Procedure (2)
The Practicality (Necessity) of Use of Clean-up Techniques for the Analysis of D/F and PCB Congeners Charles Neslund, Scientific Officer, Eurofins Lancaster.
Diagnostics Analytical 920 LC Semi-Prep 940 LC
National Air and Radiation Environmental Lab
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
David Thornton1, Xiqin Yang1, Gary Yanik2 and Leo Hsu1*
Presentation transcript:

Extraction Procedure (2) Evaluation of High Throughput, No Methylene Chloride, Low Cost Sample Clean Up for POPs Analysis Ruud Addink and Tom Hall Toxic Report, LLC Watertown MA

Extraction Procedure (2) Introduction POPs (PCDD/Fs, PCBs) continue to attract interest around the world due to strict regulations enforced in many countries Rapid and quality sample clean up and analysis is needed for many laboratories processing samples Processing times and cost are important considerations

Challenges of POPs Sample Prep Extraction Procedure (2) Challenges of POPs Sample Prep Labor intensive, prone to error Compliance with regulatory procedures and accreditation (lengthy method validation) Strict QA/QC requirements Sample matrix complexity Native background and interferences (can be orders of magnitude higher than analytes) Pico/femto-gram analyses require ultra pure extract and excellent instrument sensitivity

Automated System Advantages of Automated Sample Prep Rapid Turn Around Time: 30 Minutes for 6 Samples Cleaner Background Interferences: Closed Loop System Quality Results: Certified Prepacked Columns Green Technology: No DCM, Low Solvent, as low as 90mL QA/QC & Accreditation Requirements: Easier to Manage Computerized Method: Instrumentation based prep

Extraction Procedure (2) Manual Sample Prep Advantages of Manual Sample Prep Most labs use Manual Methods for the following reasons: No electronics or mechanical components to fail No down time due to the system failure No service contract No capital equipment cost

Challenges of Manual Prep Labor intensive, prone to error Compliance with regulatory procedures and accreditation (lengthy method validation) Strict QA/QC requirements Sample matrix complexity, lack of certified column to use Open columns, native background and interferences (can be orders of magnitude higher than analytes) Pico/femto-gram analyses require ultra pure extract and excellent instrument sensitivity

Extraction Procedure (2) Automated vs Manual Extraction Procedure (2)

Automated System Attributes Fully automated: From sample loading to elution and fraction collection Closed loop system: Cleaner background, lower detection limit High recoveries & Excellent precision: Certified columns Green Technology: No DCM, Low solvents, only Hexane and Toluene. Fast: Total Clean Up time 30-45 min. Low volumes: 100-250 mLs.

Semi-Automated System Simple to run, no computerized instrumentation Fast: 30 ~ 40 min Closed loop system to give a clean background, low level detection Use certified columns Green technology, no DCM Low solvents, as low as 90mL Economical column kits, choice of low fat, and high fat column kits No capital equipment cost No electronics or mechanical equipment to fail No downtime

Automated vs Semi-Automated Human Control Place the columns Fill Solvent reservoirs Start 3 step clean up Load samples 5 Min Elute silica 20 Min Elute Dioxins 5 Min & PCBs Micro Computer Control Place the columns Load samples Start the system & walk away Collect fractions 30 minutes later

Characteristics of Semi-Automated System Stage 1 Step 1:Load Sample Step 2:Elute Silica Solvents hexane or toluene Vacuum gauge Silica column Waste Carbon column Vacuum pump Alumina column Rotary work station

Stage 1 to Stage 2 Remove the Columns Remove Easy Connect fittings Disassemble the Columns Keep the Carbon & Alumina Rotate the work station to stage 2 Place Carbon & Alumina on Stage 2 Manifold Silica Column Carbon Column Alumina Column

Stage 2: Collection of Fractions Step 3: Collect Dioxins Collect PCBs Alumina column ready for elution Carbon column ready for elution Manifold with collection tubes

Plumbing and Steps

Attributes (1) Closed loop system: Eliminates background contaminants No washing needed. Capped solvent reservoirs Optimized for solvent reduction while obtaining highest possible recoveries Dichloromethane eliminated from clean up Ideal for food applications with PCDD/Fs and co-planary PCBs in one fraction and mono- and di-ortho PCBs in other fraction

Attributes (2) Easy sample loading on top of silica column via injection or sample vial (step 1) Connect to carbon and alumina columns with Quick Connect connections Elute silica columns with hexane and transfer all target compounds to carbon and alumina Hexane goes to waste (step 2) Rotate turntable (step 3) Install carbon and alumina columns Elute carbon and alumina with toluene simultaneously Carbon Fraction 1 with PCDD/F and co-PCBs and alumina Fraction 2 with mono- and di-ortho PCBs Collection step ~ 1 min

Column Kits with various fat removal capacities

13C PCBs Recoveries EZPrep

13C PCDD/F Recoveries EZPrep

Comparison Native Data with Automated System 2 g Fish Oil pg/g EP-110 EZPrep PCB 28 6398 6324 PCB 52 9549 10150 PCB 118 7566 7542 PCB 138 17816 19270 PCB 156 657 616 PCB 157 208 227 PCB 167 540 501 PCB 170 2013 1994 PCB 189 64 50

EZPrep Environmental Have all PCBs in one fraction, PCDD/Fs in other. Does use DCM. Load samples in hexane or toluene onto silica and alumina. Elute columns with hexane and toluene (or 10% DCM/hexane) and collect all PCBs in one fraction. PCDD/Fs still on alumina, add carbon column below. Elute PCDD/Fs off alumina onto carbon with DCM and elute carbon in reverse with toluene.

13C Recoveries with EZPrep Environmental

13C PBDEs Recoveries in Sediment with EZPrep Environmental

Conclusions (1) EZprep is low solvent and fast clean up system (30 – 45 min) 180 mL for low fat (< 0.15 g fat, mini kit) 360 mL for high fat (up to 5 g fat, HC kit) High sample throughput → 18 samples/hour 6 samples in parallel per station 3 stations fit in one hood System gives excellent recoveries for PCDD/F, PCB and PBDEs comparable to FMS’ automated systems Use of certified pre-packaged columns guarantees low native background

Conclusions (2) No DCM used in clean up No worries about breakdown or downtime No washing needed No cross-contamination Low cost EZPrep Environmental gives all PCBs and all PCDD/Fs in separate fractions.