Today AM – Need Ney Surveyor PM - Clinic

Slides:



Advertisements
Similar presentations
Rests & Rest Seats.
Advertisements

RESTS AND REST SEATS. RESTS AND REST SEATS The Component Parts of Removable Partial Dentures Denture Base Artificial Teeth Supporting Rests Connectors:
Surveying maxillary cast
Removable Partial Dentures
Alternatives to Clasp-Retained Removable Partial Dentures
Components of a Partial Denture
Rpd Design considerations
INDIRECT RETAINERS Definitions Indications for I. R. Types Factors Affecting I.R.
FIXED PROSTHODONTICS ( CROWN & BRIDGE )
Dr Kaushal Kishor Agrawal Department of Prosthodontics
(6) Seating Framework 4 (a) Test fit framework on duplicate master cast 1Use duplicate master cast for initial seating 2Inspect natural teeth and tissue.
INTRODUCTION - REMOVABLE PARTIAL DENTURE
Direct retainers (general considerations) &
Introduction to R.P.D Dr.noracheta.
TodayToday AM - Seminar AM - Seminar – Get Casts from Marjorie – Survey Class I & II Casts (no preps) – Tripod Casts – Get Heads & Mounts.
Summary of Abutment Modifications  After RPD Designed  Guideplanes  Lower heights of contour to eliminate interferences & improve esthetics  Create.
DIRECT RETAINERs By Dr hisham mously
Precision and Semi-Precision Attachments Where? When? Why?
Mandibular major connectors
Dr. Waseem Bahjat Mushtaha Specialized in prosthodontics
PREPARATIONS FOR PARTIAL VENEER CROWNS
Dr. Waseem Bahjat Mushtaha Specialized in prosthodontics
Direct Retainers Infra Bulge Direct Retainers
Removable Partial Dentures Direct Retainers
Direct Retainers Rola M. Shadid, BDS, MSc.
McCracken’s Removable Partial Prosthodontics. Chapter 10 & 19
Principles of bridge construction.
Arrangement of the posterior teeth
DL 313 Removable Partial Dentures II
BY : DR. Nora cheta. Intracoronal attachments.
Surveying the Master cast & Framework Fabrication
RETAINERS DEFINITION:
Clasps Functional requirements of a clasp:
Indications and clinical technology of manufacture of artificial crowns.
Indirect Retainers Rola M. Shadid, BDS, MSc.
Acrylic partial denture
Principles of RPD Design

WEL-COME.
Mouth preparation of partial denture. Mouth preparation is fundamental to a successful removable partial denture prosthesis. It contributes to philosophy.
LABORATORY PROCEDURES FOR PROCESSING ACRYLIC DENTURES Dr Barbara Ndagire.
Rest and Rest Seats Dr.shanai M..
Clinical Protocol for Removable Partial Dentures
Biomechanics of Removable partial denture
Today AM – Need Ney Surveyor PM - Clinic
COMPONENT PARTS OF AN RPD AND THEIR FUNCTIONS
Principles of Removable Partial Denture Design
Rotational path removable partail dentures
Removable partial denture Rests & Rest Seat
Guiding plane and Occlusal rest seat Design & Preparation
The altered cast technique
Minor Connectors Connect components to the major connector
Removable partial denture design
Direct retainer Dr.shanai m..
Dental surveyor :- is an instrument used to determine the relative parallelism of two or more surfaces of the teeth or other parts of dental arch. Surveying.
Minor connectors Dr. Shanai M..
Internal attachments (intracoronal direct retainer)
Introduction to Removable Partial Dentures (RPD’s)
Interim Removable Partial Dentures
Principles of Removable Partial Denture Design Dalhousie University
Removable Partial Denture Framework Adjustment
Removable Partial Denture Framework Adjustment
Rests & Rest Seats.
Interim Removable Partial Dentures
Clinical Protocol for Removable Partial Dentures
Minor Connectors Connect components to the major connector
Artificial crowns. Clinical and technological aspects.
Clasps Functional requirements of a clasp:
Presentation transcript:

Today AM – Need Ney Surveyor PM - Clinic Get Casts, Typodonts & Marking Sheets at front Presentations and Videos Survey Class I & II Casts (‘TYPO’)(w/o preps) Tripod Casts Get Mannikin Heads & Mounts ready for PM PM - Clinic Prepare guiding planes on Class I & II Typodonts (last sheet Course Sched) Formative Marking sheets

Surveying, Path of Insertion, Guiding Planes

Definitions Height of contour Suprabulge Undercut = Infrabulge

Rule: Retentive tip should usually be designed to be placed in the gingival 1/3

Path of Insertion Path that the prosthesis is Placed/removed Usually a single path

Advantages of a Single Path of Insertion Equalizes retention

Advantages of a Single Path of Insertion Bracing and Cross-arch Stabilization

Advantages of a Single Path of Insertion Minimizes torque on abutments

Advantages of a Single Path of Insertion Allows removal without encountering interferences

Advantages of a Single Path of Insertion Directs forces along long axes of teeth

Advantages of a Single Path of Insertion Provides frictional retention

Selecting a Single Path of Insertion Use a dental surveyor to Select path Prepare guiding planes

Parts of a Surveyor Surveying VIDEOS: Parts of a Surveyor Surveying

Guiding Plane Preparation Where rigid components contact abutments Proximal Plates Bracing Arms Rigid portions of Retentive Arms

Altering Path of Insertion Proximal surfaces similar undercuts Retentive areas similar undercuts

Selecting a Path of Insertion Modify tilt if necessary Soft tissue interferences

Selecting a Path of Insertion Modify tilt if necessary Esthetics

Once Path Selected Instructor: Approves path Demo: Mark heights of contour - carbon marker Tripod

Optimal Path of Insertion Retentive undercuts equalized Retentive arm has a different path of escapement than guiding plane, so it must flex during removal

Optimal Path of Insertion Retentive undercuts equalized Ideally, retentive arms should oppose each other on opposite sides of the arch

Optimal Path of Insertion Minimize severe tooth & soft tissue interferences

Optimal Path of Insertion Esthetics Minimize display of clasps, metal components

Optimal Path of Insertion Prepare Guiding Planes Flat surfaces parallel to path of insertion Control & limit movement of RPD Initial contacts for RPD

Effectiveness of Guideplanes Most effective when: Parallel to each other More than one common axial surface

Effectiveness of Guideplanes Most effective when: Directly opposing each other

Effectiveness of Guideplanes Most effective when: Prepared on several teeth Cover a large surface area

Videos: Preparing Guiding Planes Assessing Guide Planes Operator Positioning RPD Preps (view yourself)

Assessing Guiding Planes Proximal View Carbon Markings Facial View

Preparing Guiding Planes Select path of insertion Design Partial Denture * Select number & position of guiding planes Prepare guiding planes

Use Surveyor to Align Bur Intraorally When Preparing Guide Planes Cast should be on Surveyor Close to Operator to Compare Orientation of Analyzing Rod and Bur to the Tooth

FINGER REST!

Burs 8837K-014 Long Cylindrical Carbide or Diamond (8837K 014)

Guiding Plane Dimensions

Axial Surface Already Parallel to Path of Insertion NO Preparation !

Polish Prepared Surfaces Rubber wheels or points

Prepare Guiding Planes First

Effects of Guiding Planes On Retention & Stability Maintains Retention

Effects of Guiding Planes On Retention & Stability Minimizes Need for Retention

Effects of Guiding Planes On Retention & Stability Stabilizing Teeth

Marking Sheets