Measure Control Automate MCS Product Training Simply convincing.

Slides:



Advertisements
Similar presentations
3D Micromanufacturing Lab. School of Mechatronics Gwangju Institute of Science and Technology 3D Micromanufacturing Lab. School of Mechatronics Gwangju.
Advertisements

RWD CONTROLLERS TECHNICAL
KEB COMBIVERT F5-M Exercises.
WebStat™ Programming and Configuration of Thermostats.
Getting Started Product Description Setting Parameters How does it work Wiring Diagram.
Chapter 7 Discrete Control Using Wireless Field Devices.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
PID Temperature Controller
HASCO Hotrunner controllers Perfectly suiting your control task  A wide variety of hotrunner controllers ranging from the competitively priced single.
2008 Indication Product Workshop Temperature / PID Controls.
Date: File:PRO1_12E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation Troubleshooting.
EE330 Final Project Lithium Battery Monitor Evan Adkins and Brandon Umscheid.
Codan 5700 Series C-Band Transceiver Technical Overview.
Scope To convert panel meter based BOD incubator to a dedicated and customized control unit with enhanced feature and automation. Existing product with.
UTH-300 INSTALLATION AND MANUAL. Method of Wiring Adhesion Construction and Wiring Method #1.
Motor. What Does it Do? Monitors three phase motors for a number of current, temperature, estimated power and timing parameters. Provides motor protection.
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
InnoSys Park Brake Tool Master Control Panel Screens Revision A, 12Dec /12/20071.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
© 2013 Eaton Corporation. All rights reserved. easy Programmable Relay Training Program Exercise 3.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
SECTION 6 DESIGN STUDY. What’s in this section: –Design Variables –Design Studies Overview –Specifying an Objective –Execution Display Settings –Output.
Process Control. Feedback control y sp = set point (target value) y = measured value The process information (y) is fed back to the controller The objective.
shift to the Test Mode (Forced Operation).
Specialized Battery Emulator for Automotive Electrical Systems
Room Controller RC/A 8.1 Room Controller economic flexible modular.
Monitoring systems COMET types MS55 & MS6
Text آشنایی بیشتر با کنترلر هوشمند زیمنس
ABB i-bus® KNX Valve Drive Actuator VAA/A
EP4P03 Nuclear Plant Systems and Operation
Universal Interface, 4-fold, FM, US/U 4.2
TPS - Thyristor Power Supply for Resistive/Inductive Loads
Chapter 12. Controlling the Process
RL78 POC and LVD © 2010 Renesas Electronics Corporation. All rights reserved.
PID Temperature Controller
FEEDER PROTECTION UNIT
MPU-16A / FPU-16 TEST UNIT TUTORIAL
BRC1E61 – Energy Saving Function
17 Personnel Time Recording
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
Grid feeding monitoring relay
Module 1: System Overview
PID Temperature Controller
Training Presentation
Roof Top Unit Overview (MAGNUM)
Chiller Plant Manager (CPM)
07 Master Data – Tools
Failure types, Codes, Clearing codes
Loop Water Controller Overview
Process Capability.
Universal Dim Actuator UD/S
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
NAF Product Training.
Switching & Controlling LoB
NRL NRL - Welcome to the NRL Sales Training Program
How electronic systems work using the Systems approach.
Universal Interrupted Electronic Oil Primary R7184U Training Module
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
easYgen-3000XT Series Training
724 Temperature Calibrator
A Tutorial Overview Proportional Integral Derivative.
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

Measure Control Automate MCS Product Training Simply convincing.

Content MCS product training Basics Functionality Commissioning Excercises

MCS Device Overview 6 housing sizes 2 … 128 control loops with a single device MCS8 MCS16 MCS32 MCS64 MCSr96 MCSr128 MCS – with display of all zones MCS r – no display of all zones

MCS Hot Runner Controller Touch-Display und function keys Fuses Heatsink LED stripe „Operating Condition“ Individual display of all zones

Display and Operating Elements Outputs On / Off Home Boost Parameter settings Standby Operating mode Zone display Operating condition (green, yellow, red)

Contact for Alarm and Warning Connections Control Inputs Outputs Thermo-couples Contact for Alarm and Warning Fuses

Content MCS product training Basics Functionality Commissioning Excercises

MCS Functionality Control behaviour Automatic determination of the control parameters P I D During the heating nozzles and manifolds are classified (automatic detection between sluggish and fast control loops) and the PID control parameters determined. Suppression of overshoots At aggressive control circuits, overshooting can be reduced when heating up. Pulse mode / phase-fired control Pulse mode and phase-fired control are two different ways of controlling heating. Thus the controller reaches a high control precision, even in sensitive processes. (devices starting at 20 zones)

MCS Functionality Heating Gentle heating Gentle heating by reducing the output rate in dependance of the temperature. Group heating Zones are heated up so that they must only have a specific temperature difference from each other. Sequential heating / cooling Zones can be heated and cooled sequentially. Ramp The ramp function enables a slow and uniform heating / cooling of zones by specifying a rise / cooling curve.

MCS Functionality Zone monitoring Temperature monitoring Supervision of the zones to under- or overtemperature. Sensor monitoring The behavior at sensor break can be determined. Material leakage monitoring Irregularities in heating e.g. material leakage can be detected Leakage current monitoring Records leakage currents outside of a specified tolerance limit. Heating current monitoring The heating currents are measured for each zone. A deviation from the nominal values ​​can be monitored and displayed. Triac monitoring Device monitoring with LED indication with a defective triac.

MCS Functionality Special functions BOOST Raising the temperature of groups or individual zones for a set period of time. STANDBY Lowering of the temperature to a specific value. Diagnosis Detecting wiring faults as well as heating and sensor defects. Programs Recipes with setpoints, parameters and operation mode can be stored as programs and also be activated via the digital input.

Special functions … continued MCS Functionality Special functions … continued Flexible expansion of the zone number Several controllers can be connected into a PLUS unit. The PLUS unit works virtually like one controller. Communication For data exchange with the injection molding machine and remote monitoring of the device or for connecting the mobile control and diagnostic station MCScontrol. Monitor function Individual zones can be used only for display and monitoring. Standard parameter Resetting the parameters and settings to the factory settings.

Setting the Functions The setting of the functions are carried out via parameter. Zone parameters relate to each zone. System parameters set the device function. Zone parameters System parameters

The parameters in detail Zone parameters System parameters

Functions and Parameter Settings Use „Functions and Parameter Settings“

… the most important ones Functions and Parameter Settings Beschreibung im Dokument: Funktionen und Parameter … the most important ones

Temperature monitoring Zone parameter System parameter 1 L-Alarm 2 H-Alarm 3 dL/dH-Alarm HH HH-Alarm AL Alarm delay Description Supervision of the zones to under- or overtemperature Example Maximum upper temperature limit of all zones HH HH-Alarm Limit for overtemperature 2 H-Alarm Upper limit of the tolerance band Setpoint 3 dL/dH-Alarm Lower limit of the tolerance band 1 L-Alarm Limit for undertemperature

Sensor Monitoring Zone parameter System parameter 10 16 AP Description Alternative Zone 16 Nominal output rate AP Auto Power Description Behaviour at sensor break with the parameter AP Auto Power AP=0 Output rate = 0% The zone remains in Control Mode and must be switched manually to manual mode. AP=1 Output rate = Medium Output rate The zone is automatically switched to manual mode. The output rate will be queried. The medium output rate can be assumed or a new value must be entered manually. AP=2 As AP=1 but without confirmation query AP=3 Output rate = Nominal output rate The zone with sensor break automatically switches to manual mode and applies the nominal output rate to be specified in parameter 16. AP=4 Output rate = Alternative zone Parameter 10 specifies the zone that delivers the output rate at sensor break. 16 Nominal output rate 10 Alternative Zone

Output rate monitoring Zone parameter 17 Average output rate 18 Output rate monitoring average 19 Output rate monitoring tolerance Description The output rate monitoring serves to recognize irregularities in heating, e.g. at a leaking nozzle from which liquid plastic may leak (plug formation). When the controller is in steady state and the process is stable the controller generates internally an average output level. This average output level can be monitored for deviations (plus / minus).

Output rate monitoring Zone parameter 17 Average output rate 18 Output rate monitoring average 19 Output rate monitoring tolerance Method Step 1 Heating ... Let the system work at the setpoint for approximately 10 min. The determined value is shown in the zone parameter No. 17. Step 2 Enter this value as a kind of monitoring at the "output level setpoint" in zone parameter No. 18. Step 3 Enter in zone Parameter No. 19 the desired tolerance as a % value. Example 50% is the output level to be monitored, desired alarm at 45% and 55%, means the value "5" is to be entered in parameter No. 19.

Temperature raise / Temperature lowering Zone parameter System parameter 25 Boost Offset 26 Standby Temperature b-t Boost time Boost Temperature is raised by a fixed value for a specific time.. Standby Temperature is lowered to a new setpoint   New setpoint Current setpoint 25 Boost Offset setpoint Boost time 26 Standby Temperature b-t Boost time

Gentle heating 1 1 Zone parameter Soft start Description Soft start = Gentle heating All zones are gently heated separately of each other to max. 100 °C, independently of a higher target temperature set. Up to a temperature of 50 °C, each zone is heated with a max. output rate of 50%. From 50 – 100 °C, the output rate is determined based on the present temperature, i.e. from 60 °C onwards the output rate is 60%, etc. After 100 °C are reached, the soft-start is complete and the zone can heat up at full output. Soft start is already pre-set ex works. Parameter Zone parameter Einstellungen   11 Soft start 0: No soft start 1: This zone with soft start Standard value: 1

Group heating Zone parameter System parameter 12 Ct Description Group (combined) heating Ct Max temperature difference of the group Description Slow heating with consideration of the slowest zone This is to prevent the complete tool, manifold and nozzles from being heated up with thermal dysbalances. All zones are heated up so that they must only have a specific temperature difference from each other (system parameter Ct = Max temperature difference of the group). The slowest zone works at the maximum output rate and the other zones will be limited in their output rate so that they must only advance by the set temperature difference. The parameter 12 defines the assignment of a zone to the "Group".

Group heating … Cont. Parameter Zone parameter Settings 12   12 Group (combined) heating 0: This zone without group 1..8: Zone/group in group heating. Higher values are heated up first. System parameter Ct Max temperature difference of the group Can be set from 1° … 100° Standard value: 25° Example Zones 1 to 6 are to be heated together. The temperature difference during this heating process is to be 20 °C at most. Zones 7 and 8 are not to be part of the heating group. Settings: Zone 1 to zone 6: Parameter 12 = 1 Zone 7 and zone 8: Parameter 12 = 0 System parameter Ct = 20

Sequential heating / cooling Zone parameter System parameter 12 Group (combined) heating Ct Max temperature difference of the group COL Cooling Limit Description Zones are heated or cooled ina sequentiel order The heating process starts with the zones/groups that have the highest set value at the parameter 12 = group heating (max. 8). This is followed by the zones with the lower values. A group or zone will start its heating phase only when the preceding group or zone has reached 10 °C below the setpoint. If no zones or groups are summarized for parameter composite heating, all zones will start without delay without the function sequential heating. Sequential cooling works according to the same rules as heating, but in the reverse order.

Sequential heating / cooling Example Zone 1 is to be heated first then zones 2,3,4 are heated together. Only then should zone 5 be heated. Settings of the parameter 12 "Group heating" Parameter 12, Zone 1 = 3 Parameter 12, Zone 2,3,4, = 2 Parameter 12, Zone 5 =1

Content MCS product training Basics Functionality Commissioning Excercises

After switching on the controller … No setpoints All zones are off (outputs deactivated)

Display - and operating elements Outputs On / Off Home Boost Parameter settings Standby Operating mode Zone display Operating condition (green, yellow, red)

Commissioning steps Use Quickstart! Select Zone / Group Operating Mode Setpoints Parameters Activate outputs Use Quickstart!

Step 1: Select Zone / Group 7-Seg. Touch

Step 1b: Define Groups  Zone parameter P31 7-Seg.

Step 1b: Define Groups Touch

Step 2: Operating Mode 7-Seg.

Step 3: Setpoints 7-Seg. Touch

Step 4: Parameters 7-Seg. System-parameter: Touch

Step 5: Activate outputs

After activating the outputs … with factory settings: Classification The controller calculates the control parameters P I D (while the flashing LED strip) Soft-start The tool is in soft start heated (increasing output ratio with increasing temperature) Upon reaching 100 ° C the soft start is complete Group heating Group Heating with maximum temperature deviation of the zones of 25 ° C (standard value of system parameter “Ct”)

Warnings and Alarms Use „Troubleshooting MCS“!

Content MCS product training Basics Functionality Commissioning Excercises

Exercises Groups Operating mode Setpoints Temperature monitoring - Low Alarm - High Alarm - Tolerance band Behavour at sensor break Heating: in groups, sequential, soft-start Boost / Standby Programs

Excercise 1 Groups: Zone 1 to 3 = Group 1 Operating mode Setpoints: All zones: setpoint 80° C Temperature monitoring Low Alarm: 50° High Alarm: 110° Maximum deviation to the setpoint: 20° Maximum temperature of all zones: 150°

… Excercise 1 Activate outputs

… Excercise 1 Heating? Watch output rates and temperatures Watch alarms Analyze errors Which messages are displayed? Meaning? Activate troubleshooter Use „Troubleshooting MCS“- document

Excercise 2 Behavour at sensor break A zone should automatically switch to manual mode and continue to work with the output level of an alternative zone  Simulate sensor break

Excercise 3 Sequentiel Heating First Zone 1 Then Zone 2 Finally Zone 3 Max. temperature difference +20°

Excercise 4 no Soft start and no group heating Watch output rates and temperatures

Excercise 5 Boost Standby Boost-Offset: 10° Boost-time: 30sec Standby-Temperature: 60°

Excercise 6 Programs Current settings are saved in Program 1 Select new Programm 2 and change: New alarm limits New setpoints Select Programm 1 again Verify settings of program 1