The CIE System Dr Huw Owens
Lights, Surfaces and Observers Colour Matching Experiments Introduction Lights, Surfaces and Observers Colour Matching Experiments The CIE System Tristimulus Values Chromaticity Diagrams Dominant Wavelength and Purity © Dr Huw Owens - University of Manchester : 23/11/2018
Standing in line to See the show tonight And there's a light of Heavy glow By the way I tried to say I'd be there waiting for Dani's the girl is Singing songs to me Beneath the marquee Overload © Dr Huw Owens - University of Manchester : 23/11/2018
How can we simplify colour specification? Colour matching. The CIE System Specifying colour can be difficult. Even if a physical sample is selected from a colour order system, its appearance will probably change with changes in illuminant and viewing conditions. How can we simplify colour specification? Colour matching. Colour matching first performed by Newton (1730). He found white light could be produced by mixing yellow and blue lights. Colorimetry: A synthesis of two words, colour and metrein (Greek meaning to measure). It is the science of colour measurement. Lovibond (1887) developed a device with which he could specify the colour of beer. © Dr Huw Owens - University of Manchester : 23/11/2018
Requires three factors Colour Perception Requires three factors Light Source Observer Object © Dr Huw Owens - University of Manchester : 23/11/2018
Illuminants and Light Sources A light source is a physical emitter of radiation such as a candle or the sun. An illuminant is a table of spectral power distributions; a blueprint for a possible light source. © Dr Huw Owens - University of Manchester : 23/11/2018
A - a tungsten filament lamp Standard Illuminants In 1931 the CIE (Commision Internationale de l’Éclairage) defined 3 light sources by their SPD (relative power, 400-700nm). A - a tungsten filament lamp B - tungsten with yellow filter (sunlight) C - tungsten with blue filter (daylight) B and C no longer used. In 1964 the CIE introduced a further series of standards based on measurements of daylight and extended the spectral range. D50, D55, D60, D65 D65 used in textile industry as standard daylight No lamp available to emulate D65 exactly. © Dr Huw Owens - University of Manchester : 23/11/2018
Illuminants © Dr Huw Owens - University of Manchester : 23/11/2018
Surface Reflectance Spectra Wavelength (nm) %R 400 6.1 420 6.2 440 6.5 460 7.1 480 7.3 500 7.2 520 7.5 540 8.1 560 8.5 580 10.2 600 22.1 620 40.1 640 58.9 660 65.5 680 70.2 700 73.4 © Dr Huw Owens - University of Manchester : 23/11/2018
1924 CIE Standard Photopic Observer Brightness: Attribute of visual perception according to which an area appears to emit, or reflect, more or less light (CIE 17.4) © Dr Huw Owens - University of Manchester : 23/11/2018
Grassmann’s Laws of Additive Colour Matching Symmetry Law – If colour stimulus A matches colour stimulus B, the colour stimulus B matches colour stimulus A. Transitivity Law – If A matches B and B matches C then A matches C. Proportionality Law – if A matches B, then αA matches αB, where α is any positive factor by which the radiant power of the colour stimulus is increased or reduced, while its relative spectral distribution is kept the same. Additivity Law – If A, B, C, D are any four colour stimuli, then if any two of the following three colour matches: A matches B, C matches D, and (A+C) matches (B+D), then (A+D) matches (B+C) © Dr Huw Owens - University of Manchester : 23/11/2018
Primaries for the 1931 Colour Matching Experiment © Dr Huw Owens - University of Manchester : 23/11/2018
Colour-Matching Experiment © Dr Huw Owens - University of Manchester : 23/11/2018
Admixture of three primaries Reference Field Test Field Admixture of three primaries Reference Field Admixture of three primaries
RGB colour-matching functions CIE colour-matching experiment Wright’s observers’ results Blue Green Red © Dr Huw Owens - University of Manchester : 23/11/2018
The Standard Observer The CIE defined the colour vision of the ‘average’ human by asking a panel of observers to match the monochromatic spectral colours with red, green and blue lights, having first ‘balanced’ them to match a standard ‘white’ lamp. In 1931 the CIE converted 2 sets of results, Wright’s (10 observers) and Guild’s (7 observers), so that the white and the 3 primaries were the same. They used the equal energy white (illuminant E) and 3 monochromatic primaries. However, this still meant that at any wavelength the amount of one of the primaries was negative. © Dr Huw Owens - University of Manchester : 23/11/2018
RGB to XYZ colour-matching functions Judd suggested to the CIE that new ‘supersaturated’ primaries be defined so as to avoid negative values. These were called X (red), Y (green) and Z (blue). They were defined by drawing a triangle which was outside the spectrum locus and the RGB triangle. © Dr Huw Owens - University of Manchester : 23/11/2018
The Standard Observer The standard observer is a set of colour-matching functions. These were obtained in 1931 for a 2 degree field of view. In 1964 the CIE introduced a new set of colour-matching functions and these were obtained using a larger (10 degree) field of view. CIE 1931 2 degree CIE 1964 10 degree In 1964 the CIE also supplemented the original set of illuminants (A,B and C) with a new set of illuminants based upon the spectral power distributions (SPDs) of a blackbody radiator – these are the D illuminants. D65 is the spectral power distribution of a blackbody radiator at 6500K and is used to simulate daylight. © Dr Huw Owens - University of Manchester : 23/11/2018
XYZ colour-matching functions © Dr Huw Owens - University of Manchester : 23/11/2018
Computing Tristimulus Values λ E(λ) P(λ) Y(λ) E(λ)P(λ)Y(λ) 400 90 0.8 0.01 0.72 420 85 0.83 0.02 1.41 440 82 0.84 0.04 2.76 … 700 99 0.12 Observer (colour- matching function) Tristimulus Value Illuminant Reflectance © Dr Huw Owens - University of Manchester : 23/11/2018
Computing Tristimulus Values k is a normalising factor, k = This ensures that Y is always 100 for a perfect reflecting diffuser for any illuminant. Note that X and Z do not necessarily sum to 100. © Dr Huw Owens - University of Manchester : 23/11/2018
Table of Weights Tables of weights are reproduced in many text books that pre-multiply K,E, and X,Y,Z. © Dr Huw Owens - University of Manchester : 23/11/2018
Illuminant White Points Illuminant\ Observer X Y Z Equal Energy 1931 100.0 Equal Enegy 1964 A (1931) 109.9 35.6 A (1964) 111.1 35.2 D65 (1931) 95.0 108.9 D65 (1964) 94.8 107.3 TL84 (F11) 1931 101.0 64.4 TL84 (F11) 1964 103.8 65.6 © Dr Huw Owens - University of Manchester : 23/11/2018
The CIE Chromaticity Diagram This is a 2-dimensional x,y chart which gives an indication of colour, but removes lightness information. This can be rectified by quoting the Y tristimulus value as well as the x,y coordinates. © Dr Huw Owens - University of Manchester : 23/11/2018
However, they cannot be used to predict appearance! Tristimulus Values The XYZ values can easily be computed. They quantify the amounts of the three imaginary primaries that an observer would use to match the stimulus if used in an additive mixture. They form a specification of the stimulus that takes into account the illumination, the surface and the observer. However, they cannot be used to predict appearance! © Dr Huw Owens - University of Manchester : 23/11/2018
The CIE Chromaticity Diagram © Dr Huw Owens - University of Manchester : 23/11/2018
Dominant Wavelength and Purity © Dr Huw Owens - University of Manchester : 23/11/2018