INSPECTION OF RISK AND ANALYSIS OF INSPECTION REPORT A PRACTICAL APPROACH PRESENTED BY AJAY K. JAIN.

Slides:



Advertisements
Similar presentations
OSHA Most Frequently Cited Serious Violations
Advertisements

OSHA Most Frequently Cited Serious Violations
OSHA Most Frequently Cited Serious Violations
1 Copyright © 2013 Elsevier Inc. All rights reserved. Chapter 116.
1 Copyright © 2013 Elsevier Inc. All rights reserved. Chapter 107.
1 Copyright © 2013 Elsevier Inc. All rights reserved. Chapter 40.
1 Copyright © 2013 Elsevier Inc. All rights reserved. Chapter 28.
1 Copyright © 2013 Elsevier Inc. All rights reserved. Chapter 38.
1 Copyright © 2013 Elsevier Inc. All rights reserved. Chapter 75.
Chapter 1 Image Slides Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fire Service Pre – Incident Planning
Workplace Occupational Health, Safety and Security
OSHA Office of Training and Education
Safety in Hospitals A Computer – Based Learning Program for Students.
2.01 Understand safety procedures Environmental Safety Fire Safety 2.01 Understand safety procedures 1.
Process Equipment Warehouse A division of Mather Process Solutions
OSHA Most Frequently Cited Serious Violations General Industry - FY-2007.
Fire Protection Systems
Let’s watch a DVD… DVD Instructor Notes
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Developed by Western Iowa Tech Community College This material was produced under a grant (SH F-19) from the Occupational Safety and Health.
Work Health and Safety Section 6 ICA11v1.0
There are three types of emergencies:  Internal  External  Natural disasters.
Emergency Evacuation Zayed University, Dubai Campus.
Guidelines and Required Codes That Affect Building Design
Green Initiatives Throughout Green-collar job training – Enhance, Expand, Develop, Sustain Green practices in facilities and center culture – Construction,
FIRE Safety Solutions Dr. Pulak De FIGHT FIRE WITH KNOWLEDGE.
Cairo University Faculty of Engineering Petrochemicals Engineering Plant Layout May 2010.
Safety First: Facility Safety Inspections “Reginald C. Reese VP, Safety and Risk Management.
The Life Safety Surveyor Facility Tour
Site Planning and Layout  In the design phase of a facility, fire protection requirements are considered in the site layout  Water supply, traffic and.
Facility Management. The International Facility Management Association defines facility management as a profession that encompasses multiple disciplines.
 Presented by: Mark Jee Fire Protection Manager Facilities Management Dept. of Environmental Health and Safety Phone #: address:
BY Prashant P. Rane Safety, Health & Environment Gadegaon.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Child Care Fire Safety Program North Carolina Fire Prevention Code 2000 International Fire Code with NC amendments. North Carolina Building Code Council.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Civil engineering branches & scopes
Business Owners and Managers and the Fire Code
Church Administrators & Emergency Planning
Chapter 7 Preventing Losses from Accidents and Emergencies.
Property Risks – The Surveyor’s Perspective Stuart Blackie UK Risk Engineering - Property Snakes & Ladders Managing Risk in Higher Education 23 April 2008.
Construction Health and Safety Management By Dr Simon Smith – licensed under the Creative Commons Attribution – Non- Commercial – Share Alike License.
ONSITE EMERGENCY MANAGEMENT PLAN. DISASTER Disaster in industry may be defined as one or more emergencies which can affect several or all plants / departments,
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Risk Management Risk- Uncertainty of occurrence of any unforeseen event Pure Risk- Always leads to loss Speculative Risk- May Result in loss or Gain Static.
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
Click here for Game Rules & Instructions: Copyright © 2009, Steve Beutler, All rights.
HE UTTAR PRADESH FIRE PREVENTION AND FIRE SAFETY RULES 2005
Joint ILC/CLIC Safety document ► Incentive for this document:  Share effort to define a coherent safety protocol for future linear colliders.  Insure.
Common Rental Property Code Compliance Issues Zoning – property usage Building Inspection – minimum standards for construction Housing Code – minimum standards.
Risk Assessment and Claims. Risk Assessment -Selection of appropriate Insurance Policy -Selection of additional Covers -Type of Indemnity -Declaration.
Fire No institution is immune from fire. Flood damage can be dried out and restored, stolen property has a chance of being recovered; damage from fire.
Planning Construction Chapter 15. Private Sector  Most buildings and other structures are built for ordinary people. These people make up the private.
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
Why make a plan? Disasters change things. When an emergency happens you may have to decide what to do very quickly, while you are worrying about what.
Transfer Station Safety OR WORKER AND PUBLIC RISK.
1 Regulatory Reform (Fire Safety) Order 2005: An Insurer’s View Mark Newton Property Technical Manager Royal & Sunalliance Insurance.
Author: Eng. Abdel-Razek Rashwan QHSE Senior Consultant CAE-Egypt Safety in Global.
CITY OF HARARE EMERGENCY SERVICES
Safety and Prevention of Typical Fire Plan
FIRE PROTECTION & SECURITY in ELI Beamlines
Most Frequently Cited Serious Violations
OSHA Most Frequently Cited Serious Violations
Most Frequently Cited Serious Violations
Most Frequently Cited Serious Violations
Tosheka fire safety system
Most Frequently Cited Serious Violations
Firefighting equipment
Most Frequently Cited Serious Violations
Presentation transcript:

INSPECTION OF RISK AND ANALYSIS OF INSPECTION REPORT A PRACTICAL APPROACH PRESENTED BY AJAY K. JAIN

FIELD OF INSPECTION AND RISK ANALYSIS MOTOR O.D. ENGINEERING. FIRE.

INSPECTION OF MOTOR O.D. RISK SEGMENT OF THE VEHICLE. CLASS OF VEHICLE. PURPOSE/ USES OF THE VEHICLE. PRESENCE OF THE VEHICLE IN THE MARKET. REPARING NETWORK OF THE VEHICLE. AVAILABILITY OF SPARE PARTS AGE/ CONDITION OF THE VEHICLE.

INSPECTION OF MOTOR O.D. RISK FITMENT OF SAFETY EQUIPMENT. PAST CLAIM EXPERIENCE. CONDITION OF WIRING. INSPECTION/ VALUATION BY A COMPETENT PERSON. IMPORTANCE OF AGGREGATE NUMBERS. CONSIDERATION OF VALUE OF FABRICATED PARTS SEPRETELY MAINLY IN COMMERCIAL VEHICLES. ANATOMY OF VEHICLE.

INSPECTION OF ENGINEERING RISK TYPE OF MACHINERY/ PLANT. USES OF MACHINERY/ PLANT. RUNNING HOURS OF MACHINERY/ PLANT IN A DAY. AGE/ CONDITION OF MACHINERY/ PLANT. GENERAL MAINTENANCE/ A.M.C. OF MACHINERY/ PLANT.

INSPECTION OF ENGINEERING RISK AVAILABILITY OF SPARE PARTS. COST OF SPARE PARTS. FOUDATION/ GROUND CONDITIONS OF MACHINE/ PLANT. PAST CLAIM EXPERIENCE. AGGREGATE NOS. OF MAJOR ASSY. INSPECTION/ VALUATION BY A COMPETENT PERSON. VERIFICATION OF DEFECTS/ DAMAGES EXISTING IN THE MACHINERY.

INSPECTION OF ENGINEERING RISK SAFETY MEASUREMENTS AND PROTECTION COVERS ON MACHINERY/ PALNT. LOCATION OF MACHINE/ PLANT AND DETAILS OF SURROUNDING PROPERTY. MAINTENANCE OF LOG BOOK. TO PERSONALLY VERIFY THE RUNNING/ WORKING OF MACHINERY/ PALNT. IF THE PREMISES WHERE THE EQUIPMENT OPERATES WELL GUARDED OF NOT.

INSPECTION OF ENGINEERING RISK AVAIALBILITY OF TRAINED/ QUALIFIED OPERATORS. WHETHER COVERED BY ANY OTHER INSURANCE. IN CASE OF BOILERS AND PRESSURE VESSELS DETAILS OF WORKING PRESSURE, MAXIMUM LOAD & TYPES OF PRESSURE GAUGES/ SAFETY EQIPMENTS.

INSPECTION OF FIRE RISK COVER TYPE/ NATURE OF PROPERTY. PAST CLAIM EXPERIENCE. INDUSTRIAL RELATION SITUATION. MARKING OF MACHINERY/ BLOCKS. AGGREGAE NOS. OF MACHINERY/ MAJOR ASSY.

INSPECTION OF FIRE RISK COVER LOCATION OF PROPERTY. 01. DISTANCE FROM RAILWAY STATION, AIR PORT, NEAREST METRO CITY, NATIONAL HIGHWAY & PORT. 02. DISTENCE FROM NEAREST POLICE STATION, FIRE BRIGADE STATION & HOSPITAL. 03. DISTENCE FROM NEARBY RIVER & DAM. 04. HISTORY OF FLOOD/ INUNDATION IN THE AREA. 05. HISTORY OF ROITS/ STRIKES IN THE AREA.

INSPECTION OF FIRE RISK COVER LOCATION OF PROPERTY. 06. HISTROY OF FIRE/ OTHER PROPERTY DAMAGE LOSSES IN THE AREA. 07. THE EARTH QUAKE ZONE AS PER A.I.F.T. 08. LOWEST AND HIGHEST TEMPRATURE OF THE AREA. 09. TRANSPORTATION FACILITY AVAILABLE IN THE AREA.

INSPECTION OF FIRE RISK COVER THE COMPOUND OF PROPERTY. 1.TOTAL PLOT AREA AND BUILT UP AREA. 2.CONDITION OF BOUNDARY WALL, MAIN GATE AND SECURITY GATE. 3.SURROUNDING CONDITION OF COMPOUND. 4.CONDITION OF INTERNAL ROADS. 5.HEIGHT OF COMPOUND LEVEL COMPARED TO THE OUTSIDE AREA/ ROAD.. 6.THE WIDENESS AND CONDITION OF APPROACH ROAD OF COMPOUND. 7.WHETHER THE APPROACH ROAD HAS ANY BOTTLENECK

INSPECTION OF FIRE RISK COVER LAYOUT/ CONSTRUCTION DETAILS. 1.NUMBER OF BLOCKS WITH FLOORS. 2.BASEMENT PRESENT OR NOT. 3.DISTANCE BETWEEN DIFFERENT BLOCKS. 4.HEIGHT OF ENTRY TO BASEMENT/ GROUND FLOOR COMPARED TO SURROUNDING AREA. 5.FOUNDATION OF STRUCTURE. 6.HEIGHT OF FLOOR AND TOTAL HEIGHT OF BUILDING.

INSPECTION OF FIRE RISK COVER LAYOUT/ CONSTRUCTION DETAILS. 7. CONSTRUCTION OF ROOFING/ FLOORING/ WINDOWS/ DOORS. 8.LOCATION OF PRODUCTION AREAS, STORAGE AREAS, UTILITIES AND OFFICE AREAS. 9.PRESENCE OF COMBUSTIBLE CONSTRUCTION IN PRODUCTION AREA. 10.DISTANCE BETWEEN MACHINERY-STORAGES, ELECTRICAL PANEL-MACHINERY-STORAGES AND ELECTRICAL PANELS-PERSONS WORKING. 11.PROTECTION ON ELECTRICAL PANELS.

INSPECTION OF FIRE RISK COVER LAYOUT/ CONSTRUCTION DETAILS. 12.TYPE OF ELECTRIC WIRING – INTERNAL/ CONDUIT/ OPEN/ LOOSE. 13.TYPE OF ELECTRICAL INSTALLATION – MESSY/ DOMESTIC/ INDUSTRIAL/ FLAME PROOF. 14.CONGESTION AT THE PRODUCTION AREA. 15.CONDITION OF STOCKS IN STORAGE AREAS – PLANNED MANNER/ ON RACKS/ ON FLOOR/ MESSY. 16.PRESENCE OF ELECTRICAL APPLIANCES IN STORAGE AREAS/ TYPE OF CONNECTION.

INSPECTION OF FIRE RISK COVER SAFETY, OCCUPATIONAL HEALTH AND ENVIRONMENT. 1.FIRE PREVENTION AND FIGHTING FACILITIES – TRAINED FIRE FIGHTERS, TRAINED FIRST AIDERS, RESCUE TEAM, FIRE CHAMPIONS, DETECTION SYSTEM AT L.P.G. WITH ALARM, HYDRANTS, SPRINKLER SYSTEM, SMOKE DETECTOR, UNDERGROUND/ OVERHEAD WATER RESERVOIR, FIRE EXTINGUISHER, EMERGENCY COMMUNICATION SYSTEM, DETAIL OF HYDRANT PUMPS, FIRE TENDERS/ JEEP/ AMBULANCE AND FIRE TRAININGS AND SAFETY DRILLS.

INSPECTION OF FIRE RISK COVER SAFETY, OCCUPATIONAL HEALTH AND ENVIRONMENT. 02. FITTMENT OF DIFFERENT TYPE OF FILTERS AT ALL SOURCE OF EMISSIONS. 03. WATER CONSERVATION/ ZERO WATER DISCHARGE FACILITY. 04. WASTE MANAGEMENT/ WASTE MINIMIZATION SYSTEM. 05. PROGRAM FOR TREE PLANTATION. 06. RAIN WATER HARVESTING SYSTEM.

INSPECTION OF FIRE RISK COVER SAFETY, OCCUPATIONAL HEALTH AND ENVIRONMENT. 07. HOUSE KEEPING – CONDITION OF HOUSE KEEPING IN PLANT/ PRODUCTION AREA/ STORAGE AREA/ UTILITY AREA. STRICTNESS OF THE NO SMOKING REGULATION DISPLAY OF SIGNAGES IN PLANT.