Analyzer flow (30 lpm) Carbon vane pump Exhaust filter System vacuum gauge Spare#1 (30 lpm) Spare#2 (30 lpm) Spare#3 (30 lpm) Spare#4 (30 lpm) Blower#1.

Slides:



Advertisements
Similar presentations
Purpose of Carburetion
Advertisements

Service Section Technical Training.
Air and Water Chiller Basic Class
Basic Electricity.
Operating Nitrox Systems 11 Presented by Nuvair. Operating Nitrox Systems2 Membrane systems produce nitrox efficiently Compressed air flows through the.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Air Conditioning and Refrigeration Basics Don Gulliver February 9, 2013.
CARBURETOR CIRCUITS AND COMPONENTS
Fuel System Carburetor A device that mixes air and fuel
Pneumatic Systems (Part 2)
STEAM TRAPS.
Filter manifold Holding tank Iron- manganese filter Aeration tank Control unit Pre- filter To storage tanks Backwash overflow SO2 vent Bypass Cutoff valve.
Airflow Properties & Measurement
 Latent heat  Sensible heat  Total heat  Specific heat.
Mauna Loa, Hawaii (MLO) At MLO, the sampling stack is cantilevered away from the tower so that the stack can go through the building roof while the tower.
Simple Carburettor Fuel System for a Piston Engine
Determination of Vacuum Pump Operational Efficiency By: D K Singhal Chandpur Enterprises Ltd. 1.
Ventricle Chamber Valve Imaging Chamber ECG Machine Aortic Compliance Chamber Buffer Chamber Secondary Compliance Chamber Flow Meter Pressure Sensors DAQ.
GD150 Liquid bulk contactless compressor. GD150 Compressors.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Fuel System Fundamentals
L H H L L H Pitot tube High pressure flow Low pressure flow Pressure transmitter Magnehelic vacuum gauge Pitot tube tip Pitot tube schematic Air flow.
¾-1/2” Red. Union 3/8”OD ACSM Inlet Configuration 0.1 lpm to ACSM with PM 1 passing thru aerodynamic lens 2.9 lpm to external Pump* Sheath Flow 6 lpm dry.
Pressure Switches. New modulating and multi-stage furnaces are more complex and require that installation instructions and procedures be followed so that.
Oil Safety Control.
Introduction to Thermo Electron Instruments Robert Kinsella Sky Patton Thermo Electron.
Mentors Workshop Pneumatic Sub-System Mark McLeod Team 358 Festo/Hauppauge H.S. F For I Inspiration and R Recognition of S Science and T Technology.
Lung Volumes and Gas Distribution - Testing Equipment RET 2414L Pulmonary Function Testing Module 3.1.
Measurement of total mass concentration. 1. Sampling probe - Isokinetic or sampling from still air 2. Flow rate - Rotameter or digital flowmeter 3. Filter.
Chiller basics With Phil Rodin. Things to check when chiller is not running or is in alarm.
WBEA Passive Sampler Validation Study for NH3 and HNO3 Operation of the dual-channel Annular Denuder System (ADS)
Air Handler Terminology
HVAC- Body Works 1 Energy Analysis and Comfort Solutions Inc. Consumers – understanding how an HVAC system works.
 automotive - carburetion and controls  biological - pharmaceutical distillation  braking - trains  cathode ray tubes  environmental controls and.
Unit devices with Entrainment tutorial by Elizabeth Kelley Buzbee AAS, RRT-NPS, RCP.
PISTON ENGINE PROPULSION Chapter 5 Fuel Systems 1933 Alvis Engine 2014 Hyundai Engine Simple Carburettor Fuel System for a Piston Engine.
CHAPTER Fuel Pumps, Lines, and Filters 22 Copyright © 2016 by Pearson Education, Inc. All Rights Reserved ADVANCED ENGINE PERFORMANCE DIAGNOSIS Advanced.
Purpose of Carburetion
Exhaust to atmosphere G1 V1 V2 V3 LN2 Storage Vessel 150 l Dewar Cryostat Exhaust to atmosphere Nitrogen or helium gas bottle LN2 Circuit for MIT Test,
Available Water Flow Meter Size Typical flow depending on size
Test Programme for AC coaches
Original CPC Box schematic
OILGEAR PVV PUMPS PVV 200 Performance Curves.
LCD Wiring Diagram Presentation B / B.
Byong Guk Jeon, Ho Sik Kim NQe 401 Exp. 3 Flow measurement.
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
MVD COOLING STATUS MVD COOLING PROJECT: CHOICE of COOLING FLUID,
VALIDATION OF HVAC SYSTEM.
Emission Control Diagnosis and Service
Air Flow Measurement K. F. Chan UNIVERSITY OF HONG KONG
Pixel cooling specifications
National Laboratory Association
The Basic Direct Expansion Refrigeration Cycle
Effective Methods to Test the Fuel Pressure Regulator in your Car.
Which Parts Get Affected Due to a Bad Radiator
MINI 1A iAquaMax™ Kidney / water removal system
Pneumatic nebulizer 4. Larger particles are smashed against the
1A iAquaMax™ Kidney / water removal system
Forced draft cooling tower. NumberingEquipment A-1Storage Tank B-2Temperature sensor C-3Pump D-4Ball valve E-5Rotameter F-6Cooling water from the tank.
Characterization of Inlet Contamination Potential
Introduction to Fluid Mechanics
Determination of Vacuum Pump Operational Efficiency
Presentation transcript:

Analyzer flow (30 lpm) Carbon vane pump Exhaust filter System vacuum gauge Spare#1 (30 lpm) Spare#2 (30 lpm) Spare#3 (30 lpm) Spare#4 (30 lpm) Blower#1 Spare lines Stack excess (850 lpm) rotameters Pitot tube Magnehelic gauge (stack pitot tube delta P) Pressure transducer Blower#2 Stack excess Pumpbox – 2 blower design

There are 3 pumps in the pump box: (1)The carbon vane pump pulls the main aerosol system flow (called analyzer flow) through the system (includes nephelometer, psap and CN flow. The carbon vane exhaust is filtered because as the carbon vane pump runs the vanes break down creating small black aerosol. (2) The spare lines blower pulls 30 lpm through each of the spare lines attached to the splitter. For a basic system there are 4 spare lines although one is used to measure stack T/RH which is used to control the stack heater. (3) The excess air blower pulls 850 lpm of extra air through the main stack to create isokinetic sampling conditions. For a basic system a single blower could be used, but having two allows for spare parts and/or system expansion. There is a time delay relay box in the pumpbox to ensure that all three pumps dont start at the same time. If they did, the surge could exceed 15A and blow the pumpbox circuit breaker.

Analyzer flow (30 lpm) Carbon vane pump Exhaust filter System vacuum gauge Spare#1 (30 lpm) Spare#2 (30 lpm) Spare#3 (30 lpm) Spare#4 (30 lpm) Blower#1 Spare lines Stack excess (850 lpm) rotameters Pitot tube Magnehelic gauge (stack pitot tube delta P) Pressure transducer Pumpbox – 1 blower design Manual valve, restricts past pitot tube so can get flow past rotameters which have higher dP

There are 2 pumps in the pump box: (1)The carbon vane pump pulls the main aerosol system flow (called analyzer flow) through the system (includes nephelometer, psap and CN flow. The carbon vane exhaust is filtered because as the carbon vane pump runs the vanes break down creating small black aerosol. (2) The single blower pulls 30 lpm through each of the spare lines attached to the splitter and 850 lpm of stack excess air. Total flow=970 lpm. A manual valve is used to restrict the flow past the pitot tube so that the blower is able to pull air through the rotameters despite their higher pressure drop. Comments about flows: (a) For a basic system there are 4 spare lines although one is used to measure stack T/RH which is used to control the stack heater. (b) the 850 lpm through the stack creates isokinetic sampling conditions. There are one or more time delay relay boxes in the pumpbox to ensure that all pumps dont start at the same time. If they did they could blow the pumpbox circuit breaker.