Junctional Emergency Treatment Tool

Slides:



Advertisements
Similar presentations
How To Pull A Pre-Connect
Advertisements

Lesson 4 PUT ON A FIELD DRESSING, PRESSURE DRESSING, AND TOURNIQUET
RadiStop™ Compression Assist Device
SOF Tactical Tourniquet Components Windlass Buckle Strap Safety Screw Tri-Rings Windlass Strap.
2 Fire Fighter Qualifications and Safety Skill Drills.
The C-A-T TM is Delivered in Its One-Handed Configuration Free-running end of the Self-Adhering Band passed through the buckle forming a loop for the arm.
The C-A-T TM is Delivered in Its One-Handed Configuration Free-running end of the Self-Adhering Band passed through the buckle forming a loop for the arm.
SKI SHEETS. This type of evacuation equipment has been manufactured for hospitals, nursing homes & hospices, since the early 1980’s. These unique products.
BWST Lecture KIN 436B Spring Transfer Place chair at angle to table Secure Chair Transfer Client Provide assistance as necessary.
SAM® Junctional Tourniquet (SJT) Training sammedical.com.
The Benefits of Commercial Tourniquets
Tourniquets for the EMS Provider Connecticut EMS Advisory Board Education and Training Committee Revised April, 2013.
TCCC Guidelines: Tourniquets & Hemostatic Agents (Paraphrased)
Direct Threat Care (Hot Zone) Direct Threat Care TERMINAL LEARNING OBJECTIVE Upon completion of this module, the participant will be able to determine.
Exercise Machines KIN 436B Spring Easy Stand – Height Adjustment Depress buttons to adjust Adjust machine to accommodate client Slide bar so pin.
Tactical Medical Solutions Inc.
Utilization of the Individual First Aid Kit (IFAK)
HEAD AND SPINE INJURIES
Slide 1 Copyright © 2011, 2006 Mosby, Inc., an imprint of Elsevier Inc. All rights reserved. Chapter 6 Lifting and Moving Patients.
Utilization and Characteristics of the Individual First Aid Kit (IFAK)
 TRY TO DISTRACT THE PERSON FROM THE BAD BEHAVIOR  MAINTAIN THE PERSON’S DAILY SCHEDULE AS MUCH AS POSSIBLE  SIGNAL LIGHT WITHIN REACH  ELIMINATION.
…not the lethal, last resort tool we were all taught to never use! TOURNIQUETS.
HEMORRHAGE CONTROL RIFLES LIFESAVERS. Core SkillsControl Bleeding2 Introduction Review types of injuries Review types of injuries Review Tactical Combat.
Start an Intravenous Infusion 081-T Administering Intravenous Fluids Through a Saline Lock 081-T
The JTC Claw Sling Kit, Assembly Sling Kit includes: One “Quick Release” Sling 2 – 4” adhesive backed Velcro “Loop Tape” 2 – 7” Double Sided Velcro straps.
Combat Ready Clamp™. Medic/Corpsman carried device Aidbag-based – Partially broken down – 1.5 lbs Combat Ready Clamp™
MANAGE INJURIES BLOOD LOSS AND SAFETY Wear gloves
SOF Tactical Tourniquet. SOFTT One-Handed Application to an Arm Step 1: Open the tourniquet, exposing the loop of webbing. Grasp the running end of the.
Applying Bandages and First Aid. Next Generation Science / Common Core Standards Addressed! CCSS.ELA-Literacy.RH Determine the meaning of words.
PCI What You Need to Know!. What and Where Radial- advantages  Immediate ambulation  Easily compressible vessel  Less risk of nerve injury  Dual blood.
Chapter 15 Detailed Physical Examination. © 2005 by Thomson Delmar Learning,a part of The Thomson Corporation. All Rights Reserved 2 Overview  Detailed.
AFAMS EO Emergency Medical Field Kits (Dari) 01/09/2013.
Contra Costa County CERT Program Unit 4A – Emergency Medical Operations Bandaging and Splinting Released: 10 January 2016.
Junctional Emergency Treatment Tool
By Patrick Nicol By Patrick Nicol. 3rd year medical student Queens.
First Aid EFE Veterinary Science. Introduction Immediate on-scene assessment and stabilization Not intended to be complete or definitive diagnosis or.
Bone, Joint, and Muscle Injuries. Look For: DOTS –Deformity, open wounds, tenderness, swelling CSM –Circulation, sensation, movement Point tenderness.
WI Healthcare Emergency Preparedness Program Coalitions.
Ergonomics  An Overview of Repetitive Motion and Cumulative Trauma Injury reduction in the workplace.
SOF Tactical Tourniquet
Injuries to Muscles and Bones Chapter : Checking Circulation, Sensation, and Movement in an Injured Extremity (1 of 4) 1. Check for circulation.
SAM® Junctional Tourniquet (SJT) Training
Musculoskeletal Care SrA Heintzelman.
Combat Application TourniquetTM
Tactical Combat Casualty Care Tourniquet Use
TCCC Change Pelvic Binders
Chapter 15 Safe Patient Handling.
Combat application tourniquet (CAT)
Kendrick Extrication Device (KED)
Head, Neck and Back Injuries First Aid, Part Two
Severe Hemorrhage Control
Wheelchairs & Assistive Devices
SAM Pelvic Sling II Read the text..
Combat Ready Clamp™ The CRoC is a CoTCCC-recommended device for control of junctional hemorrhage in the inguinal area. 1.
Gait Belt, Cane, Crutches, Walker
SOF Tactical Tourniquet Components
Contra Costa County CERT - Wound Management
SAFE WORK INSTRUCTIONS
Chapter 9 Dressings, Bandaging, and Immobilization Techniques
SOF Tactical Tourniquet
SOF Tactical Tourniquet
SAM® Junctional Tourniquet (SJT) Training
Pre-Hospital Emergency Care Course
Injuries to Muscles and Bones
First Aid Lessons 1-3.
STOP THE BLEED.
Bleeding You can See First Aid.
Presentation transcript:

Junctional Emergency Treatment Tool ™ Item#: 30-0088 NSN#: 6515-01-616-5841 35 Tedwall Ct. • Greer, SC 29650

Anatomy of the JETT™ (Junctional Emergency Treatment Tool)

Instructions Overview The Junctional Emergency Treatment Tool (JETT™) includes two individually adjustable compression pads in a single tool, allowing for simultaneous occlusion of blood flow to both lower limbs (bilateral) with an easy to apply, pre-assembled, ready-to-use belt solution. The unique design of the JETT™ allows for patient transport while the device is in place and includes a lanyard and toggle solution to ensure that the Threaded T- Handle (windlass axle) does not loosen due to vibration or bumps during transport. In cases where there are bilateral injuries, the JETT™ offers a simple, safe solution for occluding blood flow to both lower extremities. This expanded capability is built into every JETT™, meaning that with standardized training the device will be pre- positioned for rapid bilateral application whether the casualty requires a unilateral or bilateral treatment. High extremity wounds in the thigh/groin region where tourniquets cannot be placed or are less effective require equipment such as the JETT™ to stop the bleeding and potentially save the life of a casualty that would otherwise bleed out in minutes. Penetrating trauma, blast injuries and amputation are examples of injuries that may require treatment with this device.

Inguinal Anatomy

STEP 1: PATIENT ASSESSMENT 1.1 Determine that the injury is not amenable to treatment with a standard tourniquet (ie: high in the thigh and/or groin region) 1.2 Determine if a bilateral or unilateral application is required

STEP 2: PATIENT PREPARATION 2.1 Remove any gear, items in pockets or debris that might interfere with the placement of the JETT™ or cause additional trauma.

STEP 3: DEVICE DEPLOYMENT 3.1 Unroll the device in preparation for application

STEP 3.2: PLACEMENT of the JETT™ 3.2.A Slide the belt with “This Side Toward Casualty” facing up under the body at the lower back 3.2.B Locate the Superior Iliac Crest and Pubic Bone, which are connected by the Inguinal Ligament 3.2.A 3.2.B

STEP 3.2: PLACEMENT of the JETT™ 3.2.C Lifting the hips, position the belt under the buttocks so that the buttocks pad is centered behind the casualty and the pressure pads are immediately below (inferior to) the Inguinal Ligament

STEP 3.3: PLACEMENT of PRESSURE PADS 3.3.A Palpate to determine the location of the Inguinal Ligament 3.3.B Angle the pressure pads parallel to the Inguinal Ligament (approximately 30°) pointing midline toward the feet making sure that both pads are correctly positioned 3.3.C Ensure that casualty’s genitals are clear of the area where the pads will be positioned 3.3.B

STEP 3.4: BUCKLE & TIGHTEN 3.4 Buckle the belt, then firmly tighten by pulling the loop handle while stabilizing the belt with your other hand on top of the belt on the casualty (remove ALL slack)

STEP 3.5: REASSESS PAD PLACEMENT 3.5 Reassess the pad placement to ensure that they are still in the correct location below the inguinal ligament

STEP 3.6: TIGHTEN 3.6 With one hand on the base plate, grip the threaded T-handle and rotate it clockwise to tighten

STEP 3.7: HEMOSTASIS 3.7 Increase pressure until bright red bleeding stops (hemostasis is achieved) and If the extremity is intact, check to confirm that distal pulse has been occluded

STEP 3.8: LOCK 3.8 Insert the toggle into the opening on the threaded T-handle (pulling the handle in clockwise rotation) and cinch it tight at the base plate in order to secure the device

STEP 3.10: RECORD TIME 3.9 Repeat as necessary with the other threaded T-handle for bilateral injuries 3.10 Note time of application on Writeable Area

STEP 4: MONITOR 4.1 Assess frequently (every 5 minutes) to ensure that bleeding is still controlled (or based on your medical protocols) 4.2 Assess after any movement to ensure that pressure pads are in correct location and that pressure was not reduced during movement (hemostasis is maintained) 4.3 Device should only be removed under physician supervision (or based on your medical protocols) 4.4 Device application should not exceed 4 hours

Warnings & Cautions Warning: • Do not leave applied for longer than 4 hours • Inguinal use only Caution: • For use by trained personnel • Tighten until hemostasis is achieved • Reassess casualty condition after movement or every 5 minutes (or based on your medical protocols) • Caution: Federal law restricts this device to sale by or on the order of a physician

Link to Online Video