Presentation Title NEMC 2018 Dale Walker, Bruce Quimby Agilent

Slides:



Advertisements
Similar presentations
Introducing AnalyzerPro. Chapter 1: Qualitative Analysis.
Advertisements

Agilent’s MX QPCR Software Tutorial Field Application Scientist
Standard Data Analysis - Integration
Orchard Harvest™ LIS Review Results Training
6 th Annual Focus Users’ Conference 6 th Annual Focus Users’ Conference Scheduling Requests and Request Reports Presented by: Sara Sayasane Presented by:
Concepts of Database Management Seventh Edition
Standard Data Analysis - Calibration
EDAX Operation Operation of the Phoenix EDAX system
Scaffold Download free viewer:
Access Tutorial 3 Maintaining and Querying a Database
10 March Setup Users. 10 March Setup Users Window Allows you to perform several user tasks –Enroll users –Enable/disable users –Set user access.
Introduction to Excel 2007 Part 3: Bar Graphs and Histograms Psych 209.
© 2013 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 1 To Block a Bill to ID from being added to a Cisco.com profile using the Manage.
Quick Start Guide: Filters Advanced Learn about: 1.What filters are and their functionality 2.How to create a filter using Samples, Equipment & Labels.
NextGen Trustee Department Disbursements This class will cover the various methods of handling department disbursements. Whether entering them manually.
2007 GeneSpring MS GeneSpring for Metabolite BioMarker Analysis using Mass Spectrometry data Agilent Q-TOF VIP Visit Jan 16-17, 2007 Santa Clara, CA Thon.
IAGAP Access Database A Tutorial. Databases There are several databases available from the IAGAP Project. There are several databases available from the.
Qualitative Data Analysis. 2 In This Section, We Will Discuss:  How to load data files.  How to use Signal Options for data display.  How to apply.
Raul Garcia-Sanchez Research Investigator: Dr. Paul R. Mahaffy Code 699, NASA Goddard Space Flight Center Research Mentor: Dr. Prabhakar Misra Department.
Using the FOCUS Web Site Teacher’s Desk. Topics Covered in this Presentation n Accessing the FOCUS Web site n Importing and Creating Classes n Adding.
© Hanson Research Corporation Deduping contacts in Sage CRM 24 th Day of November 2010.
Introduction With TimeCard users can tag SharePoint events with information that converts them into time sheets. This way they can report.
Create Lists in Millennium Jenny Schmidt SWITCH Library Consortium.
Pete the penguin says… “Before “Before the show begins, don’t forget to visit the snack bar”
Quality Assurance How do you know your results are correct? How confident are you?
FIX Eye FIX Eye Getting started: The guide EPAM Systems B2BITS.
Application of Method 1668A to the Analysis of Dioxin-Like PCBs and Total PCBs in Human Tissue and Environmental Samples Coreen Hamilton, Todd Fisher,
7000A GC-QQQ Applications Pesticides in Foods (1).
Online Catalog Tutorial. Introduction Welcome to the Online Catalog Tutorial. This is the place to find answers to all of your online shopping questions.
How to create a prompt in an Alma Analytics report Yoel Kortick | Senior Librarian.
Canadian Bioinformatics Workshops
Please wait, Our presentation will be starting soon. Use Alt+Tab key to go to other applications while the presentation is running. Use Esc key to stop.
Emdeon Office Batch Management Services This document provides detailed information on Batch Import Services and other Batch features.
PowerTeacher Gradebook PTG and PowerTeacher Pro PT Pro A Comparison The following slides will give you an overview of the changes that will occur moving.
myWizard Metrics User Guide For Base Deployed Projects
Multi-Analyte LC-MS/MS Methods – Best Practice.
Core LIMS Training: Project Management
Open source tools for data analysis
Creating Custom Reports, Macros, and Switchboards
CLASS OVERVIEW/OBJECTIVES
Accelerating Research in Life Sciences
LC-MS/MS Identification of Impurities Present in Synthetic Peptide Drugs Dr Anna Meljon*, Dr Alan Thompson, Dr Osama Chahrour, and Dr John Malone Almac.
View  text zoom  large Set properties text size to 14 point
Accelerating Research in Life Sciences
Single Sample Registration
Data Validation and Protecting Workbook
Microsoft Office Illustrated Fundamentals
Reports: Pivot Table ©2015 SchoolCity, Inc. All rights reserved.
Introduction With TimeCard users can tag SharePoint events with information that converts them into time sheets. This way they can report.
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Microsoft Office Access 2003
NextGen Trustee Receipting
eTapestry Workshop Session 3: Queries and Reports
Local Government Corporation
Tutorial 3 – Querying a Database
Managing Rosters Screener Training Module Module 5
What’s New in Universal Access for ADP Workforce Now
Microsoft Office Access 2003
Benchmark Series Microsoft Word 2016 Level 2
Word offers a number of features to help you streamline the formatting of documents. In this chapter, you will learn how to use predesigned building blocks.
Creating Contracts Today’s webinar will cover creating individual contracts, printing contracts and mass building of contracts.
Tracking the Performance of your Holdings
Best Practices for Identification and Quantitation
Bill to ID - Manage by Number: Delete from Cisco
Introduction to Excel 2007 Part 3: Bar Graphs and Histograms
Gas chromatography Software
TQ Analyst Gamal A. Hamid.
Comprehensive, Non-Target Characterization of Environmental Exposome Samples Using GC×GC and High Resolution Time-of-Flight Mass Spectrometry James Carlson,
Operation manual of AI SIDA
Presentation transcript:

Presentation Title NEMC 2018 Dale Walker, Bruce Quimby Agilent 11/25/201811/25/2018 Confidentiality Label Enhanced Target Identity Confirmation In 8270D Using Deconvoluted Spectral Matching NEMC 2018 Dale Walker, Bruce Quimby Agilent

Data Review In Routine Quantitative Analysis Like Semi-VOAS After method is developed and calibration is sucessful, running real samples begins. Identification of targets is based on: Response at the target ion within the RT window for that compound Ratio of qualifier ion responses to target response With Semi-VOA extracts, there are often significant matrix interferences that can make the qualifier ratios fall out of the calibrated range. The data reviewer must now decide between: Do not report the compound as present because the qualifier ratios were not met Report the compound as present because there was a response at the target at the correct RT and (for example) one of the two qualifier ratios was met but not the other one. A means of getting more information to decide if a compound is present would be very helpful As part of our 8270 method project, we wanted to use spectral matching to help in the decision making.

Use of Spectra In Confirming Presence Of Target Analytes MSD ChemStation QEdit users can display spectrum at apex of target ion response with baseline spectrum (lowest of either before or after) automatically subtracted. Library reference spectrum can also displayed for comparison. No library match score is provided. DRS (Deconvolution Reporting Software) Deconvoluted spectrum from AMDIS is imported and displayed with library match score (LMS), reference spectrum and baseline subtracted spectrum. Spectra imported only for those analytes where LMS > user set minimum. Deconvolution component is independent of target found by quant criteria.

Use of Spectra In Confirming Presence Of Target Analytes MassHunter Quant In MHQ, analysts can display AVERAGE (default) or APEX spectrum in data review (baseline spectrum is not subtracted.) Reference spectrum and Library Match Score (LMS) can be displayed. Works for clean, well separated peaks that are not setting on high column bleed or background ions MassHunter Quant with SureTarget Deconvolution Deconvolution greatly improves library searching of spectra by removing interfering ions from co-eluting peaks and background Used to confirm identity of target identified by traditional target/qualifiers ratio method Alternate Peak In Window feature helps detect if wrong the target peak is chosen by Quant criteria and displays better choice SureTarget in Unknowns Analysis (UA) Unknowns Analysis uses same deconvolution engine as MassHunter Quant UA is a convenient way to build libraries Use library to create Quant method Use like AMDIS for identifying unknowns Search large RT locked libraries Search NIST and industry group libraries (like AAFS)

MassHunter Quant Using AVERAGE Spectrum Same peak as in previous MSD ChemStation slides Background Ions AVERAGE spectrum with no baseline subtracted LMS = 48 Library reference spectrum

MassHunter Quant Using SureTarget Deconvolution SureTarget deconvolution removes bleed and background ions, giving much better LMS Deconvoluted spectrum LMS = 85.1 Library reference spectrum

Alternative Peak in Window Alternative Peak RT diff Presentation Title 11/25/2018 Confidentiality Label Quant method criteria chooses the primary peak based on target qualifier ratio and RT SureTarget looks for alternative peaks in RT window based on deconvoluted LMS Indicates alternative peak with highest LMS as entry in Alternative Peak RT Diff column. Warns reviewer of possible better choice based on deconvoluted LMS Peak Found By Criteria Alternative Peak New Feature in SureTarget - Exclusive to Water Screener Alternative peak RT Diff indicates the time difference between the primary peak (green peak above at 5.584 min) and the alternative peak, which is 0.145 min after the primary peak. The deconvoluted spectrum of that primary peak does not have a good match with the reference library spectrum. The ethyl methanesulfonate peak was identified initially with a match score of 14, which is very low and the deconvoluted MS is not a good match to the library spectrum; however, there is an alternative peak entry in the alt peak RT diff column. We can investigate this peak by using the manual integration tools. LMS = 14.5 Deconv. spectrum Spectrum of peak found by criteria Library reference spectrum

Alternative Peak in Window Alternative Peak RT diff Presentation Title 11/25/2018 Confidentiality Label Use Manual Integration button to select alt peak Corresponding info of selected peak is updated in the batch table (RT, LMS, response, etc.) New Feature in SureTarget - Exclusive to Water Screener If we use the manual integration tools, we can click on that alternative peak at 5.729 min to look at the target ion, qualifiers and deconvoluted spectrum, along with the Library match score. Selecting the peak at 5.729 min shows a match score of 81.3 and the deconvoluted mass spectrum is a very good match (as indicated by the library match score). The raw spectrum is shown as an example of how well deconvolution works at pulling out the important fragments of ethyl methanesulfonate, while removing the interfering fragments related to the background/matrix. Spectrum of alternative peak LMS = 81.3 Library reference spectrum

Adding Deconvolution To MassHunter 8270 Semi-VOA Quant Method Build library of spectra from 10 ppm calibration standard containing all 84 analytes and ISTDs Use Unknowns Analysis to deconvolute spectra for library Search spectra against NIST Delete all identified impurities components that are not part of the method Use Show Alternate Hits feature to correct misidentified spectra (isomers, etc) Export desired spectra to MassHunter Library Builder program Edit names and CAS numbers to match those entered in Quant table In Quant Edit Method screen Select Workflow/Target Deconvolution Setup In Setup screen, fill in Reference Library, Library Method, and Outlier Setup Items In Quant Batch screen Add columns for RT Diff, Library Match Score, and Alternative Peak RT Diff

Adding Deconvolution To Quant Method: In Method Edit View Click On Target Deconvolution Setup Fill In Library and Library Method Info Here AND Globals

Add These Columns To the Batch Screen

20 ppm 8270 Semi-VOA Calibration Standard, 84 Compounds Including ISTDs With so many compounds, it is almost impossible to avoid co-elutions, which cause identification problems. Deconvolution helps resolve these Pentachlorophenol

Pentachlorophenol With Apex Spectrum APEX spectrum has library match score (LMS) of 88.8. There is still some interference with a large 169 ion 169 ??

Pentachlorophenol With Deconvolution In Quant Deconvoluted spectrum has improved LMS = 97.2 Note that 169 interference is gone. What was 169 from?

Unknowns Analysis Deconvolution Finds Co-eluting Impurity Deconvolution produces clean spectra from peaks only 0.005 min apart Pentachlorophenol (LMS = 97.2) 4-Aminobiphenyl (LMS = 93.6) 169 base peak of 4-Aminobiphenyl interferes in Pentachlorophenol apex spectrum

Analysis Of Semi-VOA Extract Provided Environmental Lab Semi-VOA extracts often look like diesel fuel, which means lots of potential interferences Is Benzo[b]fluoranthene in here?

Analysis Semi-VOA Extract Provided By Environmental Lab Target ion 252 has response at 0.066 min from quant table RT. Qualifier 253 is good (107%) Qualifier 125 is out (237%) TIC shows interference(s) Is it there or not? TIC Shows Coeleuting Interferences Target Ion 252 Qualifier 125 out of range

Analyze Semi-VOA Extract Provided By Environmental Lab Based on qualifier way out and APEX spectrum LMS = 52, Benzo[b]fluoranthene is absent Based on deconvoluted LMS of 90.1 AND RT diff of only 0.066 min, Benzo[b]fluoranthene is present APEX Spectrum LMS = 52.1 Deconvoluted Spectrum LMS = 90.1

Summary SureTarget Deconvolution features added to MassHunter Quant programs offer useful new tools for routine analyses: In MH Quant For data review in Quant Batch table, deconvoluted spectra with library match score helps confirm presence/absence of target analytes, especially for samples with matrix interferences Alternate Peak in Window function alerts user if Quant criteria has chosen wrong peak and makes it easy to correct. Unknowns Analysis Deconvolution simplifies identification of compounds, both targets and unknowns Use it to build libraries from calibration standards For users that only occasionally encounter matrix interferences, use Unknowns to inspect data file instead of in Quant review.

Thank you for your attention!