The new industry standard (1 UPS for 15,000 ft2)
The New Industry Standard Leading Choice for Internet Data Centers MGE now has taken the lead in Internet Data Center Power Protection Recognized by the Industry leaders for getting systems on-line / on time
Product Offering kVA 800 kVA 750 kVA K/W PF 0.9 0.95 All models share the same body and dimensions
Options Very simple to specify and order Core Product Options Details Multi-Module UPS SSC / MBP Same SSC and MBP on all EPS 6000s (5000 A SSC TBA) Single Module UPS MBP (fixed) Bottom Entry Adds extra cabinet / allows bottom entry Graphical Interface Advanced display to simplify operation (one display for 6 units & SSC) COMM + 2 Additional two serial ports Remote Battery Disconnect DC Disconnect for Battery Racks Distribution Output Distribution Breakers (non-matching) Very simple to specify and order All models include input isolation transformer and filter
UPS Topology and Physical Characteristics
Compact Footprint 121” 135” 720 kW 22 kW/ft2 120” 120” 600 kW Multi-Module Single Module kW 121” 135” 720 kW 22 kW/ft2 Power Density 120” 120” 600 kW 18.5 kW /ft2 600 kW 17 kW /ft2 127” 149” *675 kW *19.5 kW /ft2 All models w/ 12 pulse rectifier Close to 20% more power in the same footprint New 800 KVA Old MGE 750
Single Module Dimensions Split Split Bypass/ MBP I/O Cabinet UPS Cabinet 82’’ 39’’ 60.0” 61.0” 22.0” MBP 14.0” Bypass 135’’ Includes: Input isolation transformer & input filter Add 22.0” for bottom entry cabinet
Single Module Components Bypass Cabinet (Q4S) (Replace with Optional MBP) I/O Cabinet UPS Cabinet
Maintenance Bypass Options Ultra compact bussing reduces cabinet width to 22” Fits in wider version of bypass cabinet Strongly recommended for isolating single modules Kirkey interlocks standard For single or dual configurations Maintenance Bypass Cabinet (Q4S, Q3BP, Q5N)
Single Module Schematic 100% Solid State MBP (22” Cabinet / includes Q4S) Bypass (14” Cabinet)
Multi-Module Dimensions I/O Cabinet UPS Cabinet 82’’ 39’’ Yes! It comes in red too! 121’’ Includes: Input isolation transformer & input filter Add 22.0” for bottom entry
Multi-Module Components I/O Cabinet UPS Cabinet SSC is the same as the EPS6000 standard SSC MBP is also identical to the EPS 6000
Multi-Module Schematic
Rectifiers (top/bottom) UPS Topology Blowers (3) Blowers (3) Rectifiers (top/bottom) Static Switch Input CB Clear panel for thermal scanning Input Filter Caps Output CB (Q5N) Fan Xformer Input Transformer / series choke in front Fan Fuses Fan Fuses Seismic mounting holes Multi-module I/O Cabinet
I/O Cabinet – under construction Cable I/O I/O Cabinet – under construction
UPS Topology UPS Cabinet Blowers (3) Blowers (4) Inverters (6) DC Capacitors Inverters Fans (3) Transparent Viewing Port Inter-cabinet Connections Output Filter Capacitors (4) Card cage DC Connection Neutral UPS Cabinet
DC Components DC disconnect (option) is a 2000 A breaker / cabinet (remotely mounted) Same 480 DC Bus (40 cells) as EPS 6000 – may have more cells than others but DC current & cost of ownership is lower!! 90’’ DC DISCONNECT (2000 A) 28’’ 36’’
Easy Installation 6,000 lbs. per spilt Transformer is also front removable & sits on rail assembly Pallet Jack(s) both sides Fork Lift
Very “manageable” wiring installation
Q4S – Bypass Maintenance Bypass
Output Performance
Fault Tolerant Circuitry Output Performance Fault Tolerant Circuitry A B C Dead short across the output bus will not damage the UPS Wiring changes on the critical bus are common today Other UPS will suffer fatally from output shorts
Precision Voltage Regulation Digital Power Quality Feedback Loop <4% THD even when powering non linear loads A high resolution true sine wave output Prolongs life and avoid premature failure of switch mode power supplies
Optimized For Power Supplies Even in worst cases conditions output remains a pure sine wave Input current of power supplies is limited avoiding overheating distributing the distortion among the critical loads
Output Performance Other UPSs may have sub cycle distortion of 18% on a single phase 100% step load means 0%-100%-0% load (not 50% to 100%)
Efficiency Myths Exposed You said it gets 50 mpg I meant driving downhill CAUTION GENERALIZED STATEMENTS
Interpreting Efficiency w/o input isolation transformer w/ input isolation transformer and filter
Comparing Efficiency MGE maintains efficiency!! Caution: Most published efficiencies not with input isolation or input filter Manufacturers are also subject to best case scenarios MGE Other UPS MGE maintains efficiency!!
Cost Savings YOUR MISSION: Equate operating costs to capital costs $ 0.06 / kWh $ 0.10 / kWh
Easy Maintenance Modular components with low MTTR (mean time to repair) Low MTTR means higher availability –
Easy Maintenance Rapid fan assembly swap Filter replacement w/ UPS on-line Easy viewing of capacitors
No Side or Rear Access 800 kVA 33.0 ft2 Rear view of series 800 No rear access saves: 30 ft2 No side access saves: 9 ft2 800 kVA 33.0 ft2 40 ft2 saved!! Easy front thermal scanning of all components Rear view of series 800 All mechanical electrical bonds are front accessible
Multi-port Communications Interface COMM+2 Card Features 3 communications ports w/o GUI display 2 communications ports w/ GUI display Field retrofittable COMM+2 Serial Port Expansion (adds two ports to EPS 6000) Choose any one option (standard 6000) or add COMM+2 card and choose any three options Dry Contacts (standard) 11 x Dry Contacts (alarms) 9 x Dry Contacts (control) U-Talk / RS232 Port 2 J-Bus (RS232 or RS485) standard Port 3 DB9 Port (standard) Reserved for Field Engineer Diagnostics Port 1 SNMP Adapter Teleservice GUI Display
Communications Protocol MGE Uses J-Bus protocol to communicate with other devices via serial communications links A subset (part) of the most popular for industrial communication protocol Open protocol - most devices have ModBus drivers which usually work for J-BUS Communication registers available from MGE Most building Management and Monitoring system can communicate with MGE Three Phase UPSs
Graphical User Interface Mimic screen Alarm/event log 86 electrical parameters Graphing 96 hour rolling memory
Graphical User Interface Touch screen PC based system - Large 10.2” TFT LCD display Non-critical to UPS operation (standard LCD and controls remain) PC based display using Embedded NT operating system Utilizes MGE Monitor-Pac software One unit can monitor multiple UPSs and SSC’s
12 Pulse Rectifier / Low kVAR Input Filter
Causes of Generator Incompatibility Leading input power factor caused from capacitive content of input filter High kVARs kVAR (amount of reactive power) High input distortion MGE is <12% w/o filter
MGE Stays on the Right Side of the Line!
Generator Friendly Technology Series 800 features: No leading power factor Very low kVAR Low input distortion (5-7%) 100% solid state filter / no hard switching of caps / distortion like load activated filters Permits generator to UPS sizing as low as 1:1 (theoretically) ADVANTAGE MGE
Reliability - The only things that really matters Series 800 credentials: The series 800 is a mechanically optimized EPS6000 All control and PCB’s from EPS 6000 Extensive testing (one year) prior to release Units installed before yours - (15-100) EPS 6000 reliability since 1995 (excellent) No mechanical / contactors in power flow No technology risk “An optimized version of the EPS 6000”
Liebert Series 600 T
Powerware 9315
In Production! Dedicated 800 kVA Production Line in Full Operation
Why MGE? Fault Tolerant Circuitry Reliability Advanced Battery Management Easy to Maintain & Install Open Protocol Communications Graphical User Interface Reliability Leading Choice for Internet Data Centers Highest "real life" Efficiency Highest Energy Density Precision Voltage Regulation Low Input Distortion Generator Friendly Technology
Bypass / Maintenance Bypass
Multi-Module Dimensions
The Efficiency Leader Lowest operating costs under “real world” operating conditions At partial loads and non-linear loads MGE efficiency is the clear winner Operating cost savings can equal the capital cost of the UPS in three to five years
Maximum Power Density
Advanced Battery Management V battery Available ( utility present ) I battery AUTONOMY Software Calculation kW load Remaining ( utility not available) End of autonomy pre-alarm Ambient temp. Remaining time / life Battery age New fully charged battery parameters : Accurately predicts time remaining and battery life by incorporating all relevant data into calculations Also “maximizes” available time before shutoff Temp. compensation prolongs battery life