ABB i-bus® KNX Analogue Input

Slides:



Advertisements
Similar presentations
© 2003 ABB STOTZ-KONTAKT GmbH Gerd Schlag Folie 1 AN INTRODUCTION TO DALI.
Advertisements

Analog Value Processing
MTE´s Portable Product Portfolio
We are Group5 Weatherstation The team Members are : Saran Jackson Robert Howard Robert Garvey Gene Fitzgerald Steven Dowling.
1 INPUT & OUTPUT ■ INPUT * Voltage Side ( PT side ) Operational range : 0-110% Permissible over range : 150% for 10 seconds 120% continuously * Current.
The special unit for special tasks.  Installation possibilities Private area Special object Industrial park.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Lab instruments ELCT 201 Digital Multimeter Voltage Tester
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
ABB i-bus® EIB Shutter Actuators
Product Overview Analogue Input, 2fold, SM  Box  Sensor connections
ABB i-bus® KNX Fan Coil Actuator FCA/S
Fan Coil Actuator FCA/S 1.x.x.2
ABB STOTZ-KONTAKT GmbH Intrusion Detection Technology SSM/x SafeKey Switching Module 2011 | Slide 1.
Fan Coil Controller FC/S 1.1
AN INTRODUCTION TO DALI
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Weather Unit, Weather Sensor
G. Schlag / STO-GM / Novembre 2012
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX i-bus® Tool
ABB i-bus® KNX Application Unit Logic ABL/S 2.1
DALI-Gateway DG/S 1.1.
ABB STOTZ-KONTAKT GmbH DALI-Gateway DG/S
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX ISx/S 5.1 IP Switch Master and Slave IPM/S 1.1 IP Patch Module © STO/G - Slide 1.
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Line Coupler LK/S4.2
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
AA/S 4.1 Analogue Actuator AAM/S 4.1 Analogue Actuator Module
ABB i-bus® KNX Weather Station
August 2012 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Energy Module EM/S Energy Actuator SE/S © ABB 20 May 2018 | Slide 1.
ECAL Front-end development
ABB i-bus® KNX Fan Coil-Actuator FCA/S 1.1M
ABB i-bus® KNX Room Solutions
Blower-/Fan Coil-Actuator
ABB i-bus® EIB Display and Control Tableau
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
ABB i-bus® KNX Weather Unit , Weather Sensor
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Telephone Gateway TG/S 3.2
ABB i-bus® EIB Electronic Switch Actuator, 4-fold
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Premium, RM/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
HD SIGNAL CONDITIONER SERIES
What is meant by ‘Preventive Monitoring’?
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
EPR = Electronic Products and Relays
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Time Switch FW/S 8.2.1
Jörn Kruse / STO-G / Mai 2009 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX The „smaller“ Room Controller RC/A 4.2 © STO/G - Slide 1.
ABB Stotz-Kontakt GmbH ZS/S 1.1 Meter Interface Module
ABB i-bus® EIB / KNX Elektromotor Valve Drive ST/K 1.1
Jörn Kruse / STO-G / ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Brightness Sensor Interface HS/S © STO/G - Slide 1.
ABB STOTZ-KONTAKT GmbH
ABB i-bus® EIB / KNX Binary Input BE/S x.x.1
ABB i-bus® EIB / KNX Fault Monitoring Unit SMB/S 1.1
Electric Current.
4 channels, each as input or output
2 channels, each as input or output
Electronic relay ER/U 1.1 contact TU/W 1.1 US/U 4.1 ER/U 1.1
Commissioning Power Supply NTI/Z
Universal Interface, 12-fold, FM US/U 12.2
Universal I/O Concentrator UK/S 32.2
ABB i-bus® EIB Logic Module LM/S 1.1
Click to Continue to Calculator window
ABB STOTZ-KONTAKT GmbH DALI-Light Controller DLR/S M
Ohm’s Law The relationship between voltage, current and resistance is known as Ohm’s Law: V = IR Voltage (V) = Current (I) x Resistance (R) Volts.
ABB i-bus® KNX The new I/O-Actuators IO/S and IO/S
The rheostat (or variable resistor)
Universal Dim Actuator UD/S
ABB i-bus® EIB / KNX Data Logging Unit BDB/S 1.1
AN INTRODUCTION TO DALI
Presentation transcript:

ABB i-bus® KNX Analogue Input Intelligent Building Control ABB i-bus® KNX Analogue Input © ABB STOTZ-KONTAKT GmbH 2CDC504111N0201 | Page 1

ABB i-bus® KNX Analogue Input, AE/S 4.1.1.3 Registration and processing of 4 different analogue input signals Integrated power supply to provide the sensors, 24 V DC / max. 300 mA (over 115…230 V AC) Connection of any sensor with 0…1 V, 0…5 V, 0…10 V, 1…10 V, 0…20 mA, 4…20 mA, 0…1000 Ohm, PT100, PT1000 and potential free contact © ABB STOTZ-KONTAKT GmbH 2CDC504111N0201 | Page 2 2

ABB i-bus® KNX Analogue Input, AE/S 4.1.1.3 Free adjustable signals from sensor Measured value visible as 1 bit [0/1], 1 byte [0...+255], [-128...+127], 2 byte [0...+65,535], [-32,768...+32,767], 2 byte [floating point], 4 byte [IEEE floating point] Filtering within 4, 16 or 64 measurements Threshold value: 2 for each input with upper and lower limit / threshold values, can be modified via the bus Comparator / arithmetic function / mean value © ABB STOTZ-KONTAKT GmbH 2CDC504111N0201 | Page 3 3

ABB i-bus® KNX Analogue Input, AE/S 4.1.1.3 Minimum duration of underflow and overrange adjustable (If the sending condition reverts during the minimum duration, no telegrams are sent) Offset temperature +/- 5°C Line fault compensation at PT100/PT1000 resistance via cable length or via cable resistance Auxiliary voltage for sensor supply Integrated in the i-bus Tool © ABB STOTZ-KONTAKT GmbH 2CDC504111N0201 | Page 4 4

© ABB STOTZ-KONTAKT GmbH 2CDC 505 143 N0101 | Seite 5