Michela Powell-Hernandez Senior Environmental Scientist, EcoChem, Inc.

Slides:



Advertisements
Similar presentations
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
Advertisements

Office of Water PittCon 2001 Status of EPA Method 1631 for the Determination of Low-Level Mercury Maria Gomez-Taylor Analytical Methods Staff U.S.
1 ASSESSMENT OF FIVE TECHNOLOGIES FOR MITIGATING ARSENIC IN BANGLADESH WELL WATER ETV-AM Environmental Technology Verification – Arsenic Mitigation Based.
Module 6 Effluent Monitoring and Receiving Water Monitoring.
427 PHC. Direct-Current Plasma  A direct-current plasma (DCP) is created by an electrical discharge between two electrodes. A plasma support gas is necessary,
Analytical Chemistry.
IDDepth δ 13 CCarbonNitrogenδ 13 C Depth: (cm)(‰)(%) (‰)(cm) Gr. 3-5A %0.17% Gr %0.12% Gr %0.09%
Christopher Guerrero, Steven Pacenka, Tammo Steenhuis Department of Biological and Environmental Engineering, Cornell University (Summer 2011) Acknowledgments.
Detection of Copper in Wastewater Seth Holm Chem4101 December 2009.
Introduction: We will start with an overview of treatment processes 1) Why do we treat water and wastewater? The main objectives of the conventional wastewater.
Verifying the Use of Specific Conductance as a Surrogate for Chloride in Seawater Matrices Rob Mooney Technical Marketing Manager In-Situ ® Inc.
Chemometrics Method comparison
1 FDA Survey of Lead in Pharmaceuticals John F. Kauffman, PhD R&D Team Leader CDER, Division of Pharmaceutical Analysis ACPS-CP Meeting July 22,2008.
Materials Characterization Lab Elemental Analyses by ICP-AES Henry Gong, Senior Analytical Chemist September 10, 2008.
Marcellus Shale Wastewaters Management by Resource Recovery Shale Gas Innovation Contest Ben Franklin Technology Partners April 13, 2012 Timothy Keister,
FGD MONITORING PROJECT ORSANCO Technical Committee Meeting June 4, 2013 Item 8a.
Perchlorate Analysis by Ion Chromatography The CA DHS Protocol H.S. Okamoto, D.K. Rishi and S.K. Perera.
Sulfates Presentation By Douglas Rittmann, Ph.D., P.E. Water/Wastewater Consultant To CE 4153 Lab Course On February 7, 2006.
Quality by Design Application of Pharmaceutical QbD for Enhancement of the Solubility and Dissolution of a Class II BCS Drug using Polymeric Surfactants.
Collection and Preservation of Water and Wastewater Samples
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
1 / 9 ASTM D19 Method Validation Procedures William Lipps Analytical & Measuring Instrument Division July, 2015.
Copyright 2008 © Silliker, All Rights Reserved Collection of Samples for Chemical Analysis.
Acids… Learning objectives: Know that salts are formed from reactions with acids. Know how to write correct word equations. Know what salts are formed.
: Heavy Metal Contamination in Highway Marking Glass Beads NJDOT Research Study: Heavy Metal Contamination in Highway Marking Glass Beads Conducted by:
EPA REGION VI MINIMUM QUANTIFICATION LEVELS (MQLs) WHAT THE “L” IS GOING ON? 25 th EPA Annual Pretreatment Workshop Addison, TX 8/5/09 Allen Gilliam ADEQ.
Representative Sampling. Samples vs. Populations The population is the total or all of the possible answers we might get by sampling. All of the individuals.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
The Islamic University of Gaza- Environmental Engineering Department
ACWA – RECYCLE RESEARCH Presentation to the ACWA National Convention August 2009.
Preliminary Scoping Effort. Presentation Objectives Identify need for additional sources of future funding Provide background on how elements were identified.
Providing comprehensive scientific resources to environmental clients worldwide. Dissolved Gas Analysis: A Review and Comparison.
1 Chapter 2 Steps in a chemical analysis Plan of analysis Before doing any quantitative analysis, the following questions should be answered: 1-
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Chapter 1: The Nature of Analytical Chemistry
Fundamentals of Analytical Chemistry Eighth Edition.
On-site, laboratory-grade, rapid-response testing
Determinations and Interpretations of FTIR Detection Limits
The Method Update Rule Does this affect me? HOW?
Environmental Analytical Laboratory Sierra Nevada Research Institute
Serpil KILIÇ, Murat KILIÇ
Clean Water Act Regulations affecting Electric Utilities
Status of EPA Method 1631 for the Determination of Low-Level Mercury
Overview of EPA Method 1631, Revision E By Roy W
ACWA – RECYCLE RESEARCH
Characterization of Dissolved Solids in the Ohio River
Major stages in making chemicals
* Metal in pickling waste (mg/L)
This is the default title slide for Thermo Fisher Scientific
Discussion and Conclusions
Performance Analysis of Textile Industry Wastewater Treatment Plant with Physicochemical Characterizations Tadele Assefa Aragaw Faculty of Chemical and.
EPA Method Equivalency
CITY OF MARSHALL CHLORIDE ISSUES September 26, 2017
Technical Sales & Support Chemist
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Technical Support Chemist
Practical clinical chemistry
The Analysis of Soils and Waters in Accordance with U. S
Ultimate Clean Digestion Cups and Clean Lab Testing
EPA Method Equivalency
What it Means, Why it Works, and How to Comply
Concentration.
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Choice of Methods and Instruments
Chapter 1: The Nature of Analytical Chemistry
Quantifying the Efficiency of Different Solid Sample Digestion Methods: A Comparison of Time, Cost, and Accuracy Connie Hayes.
A Holding Time Evaluation Study for the Analysis of PFAS in Aqueous Samples Charles Neslund, Scientific Officer, Eurofins Lancaster Laboratories Environmental,
CITY OF MARSHALL CHLORIDE ISSUES NOVEMBER 22, 2016
Chlor-Alkali Industry
Introduction To Medical Technology
Presentation transcript:

Multi-Laboratory Study of ICP-MS for Analysis of Selenium and Arsenic in FGD Wastewater Michela Powell-Hernandez Senior Environmental Scientist, EcoChem, Inc. Naomi Goodman Senior Technical Leader, EPRI National Environmental Monitoring Conference August 9th, 2018

Presentation Overview Project Background & Approach FGD Wastewater Sample Characterization Study Multi-laboratory Study Method Variability Evaluation Conclusions & Recommendations Acknowledgements

Project Background Effluent Limitations Guidelines (ELG) for U.S. coal-fired power plants set stringent limits for flue gas desulfurization (FGD) wastewaters Arsenic (As) and selenium (Se) quantification in FGD wastewater below the ELG limits will be highly challenging Interferences from dissolved salts Instrument limits on total suspended solids Potential interferences from rare earth elements (REE) Parameter Long-term Average Maximum Daily Limit Monthly Average Limit Total arsenic, µg/L 5.98 11 8 Total selenium, µg/L 7.5 23 12

Characteristics of Typical FGD Wastewaters FGD wastewaters contain high concentrations of sodium, magnesium, calcium, strontium, silicon, boron, chloride and sulfate at parts-per-million to percent levels Parameter Low (mg/L) High Calcium 680 5,700 Chloride 1,100 23,000 Magnesium 210 5,800 Sodium 50 1,900 Sulfate 1,200 13,000 Total Dissolved Solids (TDS) 3,000 42,000 Total Suspended Solids (TSS) 6.0 65

ICP-MS with Interference Reduction Technology Inductively Coupled Plasma Mass Spectrometry (ICP-MS) – EPA Methods 200.8/1638 Collision reaction cell (CRC) Dynamic reaction cell (DRC) Triple quadrupole (QQQ)

Examples of Interferences for Arsenic and Selenium Biases due to: Spectral interferences Physical interferences Ionization enhancement Memory effects High total dissolved solids Other chemical additives Bromine used in mercury control Reduced sulfur additives Element Mass Interferences As 75 59Co16O+, 36Ar38Ar1H+, 36Ar39K+, 40Ar35Cl+,38Ar37Cl+ 43Ca16O2+, 23Na12C40Ar+, 12C31P16O2+, 40Ca37Cl+, 150Nd++, 150Sm++ Se 78 40Ar38Ar+, 38Ar40Ca+, 41K37Cl+, 156Gd++, 156Dy++

Help laboratories improve ICP-MS techniques Project Objectives Help laboratories improve ICP-MS techniques Use appropriate sample preservation Achieve the necessary sensitivity Overcome analytical interferences Develop good quality control procedures Expand the pool of qualified laboratories Communicate best practices Provide samples for self-evaluation Educate power plant environmental staff Selecting a commercial laboratory Evaluating ICP-MS data

Select 4 wastewaters for multi-lab study Project Approach Prescreen candidate biologically treated FGD wastewaters (Se, As < ELG limits) Select 4 wastewaters for multi-lab study Obtain bulk samples Prepare and distribute homogenized samples to participating laboratories Prepare and distribute one synthetic FGD wastewater Collect, review and summarize laboratory data, recommend enhanced techniques

FGD Wastewater Sample Characterization Study

Sample Characterization Study Objective: Identify appropriate samples for study Study effects of container type, preservative, and digestion method Measure total recoverable Se, As, sample stability over 1 month Measure rare earth element (REE) interferences Neodymium, samarium interference on As Verify stability of Se, As for one month from collection REE: Neodymium

Analytical instrument Study Variables Sample bottles HDPE bottles Glass bottles Sample preservation Unpreserved 1% nitric 1% nitric, 1% hydrogen peroxide Sample digestion EPA 200.8 hot block digestion EPA 200.8 modified with closed-vessel, oven bomb digestion Analytical instrument ICP-QQQ-MS ICP-CRC-MS (subset of samples)

Closed Vessel Digestion A sample aliquot was placed into a PFA closed-vessel oven bomb Samples preserved to a final 2% (v/v) nitric acid and 1% (v/v) hydrogen peroxide concentration Heated to a minimum of 85°C for at least 4 hours to ensure complete metal dissolution

Sample Stability Study Samples were stable over 1 month When stored in HDPE or borosilicate glass When preserved with 1% nitric 1% nitric : 1% peroxide Unpreserved

Selenium Digestion and Preservative Effect Low bias seen with open digestion, but effect not seen when samples were preserved with 1% nitric : 1% peroxide.

Arsenic Instrumentation Effect Potential high bias for some waters when analyzed by ICP-CRC-MS vs. ICP-QQQ-MS.

Multi-laboratory Study

16 participating laboratories Multi-Lab Study Scope 16 participating laboratories 10 utility labs 6 commercial labs 4 biologically treated FGD wastewaters (3 blinded replicates) Only one site from the prescreening study was available for use in the multi-lab study Fortified with selenium and arsenic to ~ 8 ppb (target) Preserved with 1% nitric, 1% hydrogen peroxide 1 synthetic FGD samples (3 blinded replicates) Short-term stability study Analysis by within 48 hours of receipt, at 1 week from receipt, and again at 1 month from receipt

Selenium Stability Study

Arsenic Stability Study

Multi-Laboratory Study Evaluation

Multi-Laboratory Study Evaluation Most laboratory results were within +/- 20% Difference of the consensus mean value. Potential laboratory bias was estimated if results fell outside this window.

Multi-Laboratory Study Evaluation The Synthetic FGD results were highly variable. Arsenic (8.2 µg/L to 310 µg/L) Selenium (7.1 µg/L to 210 µg/L)

Interference Reduction Type Variability - Selenium Outlier Results

Interference Reduction Type Variability - Arsenic

Cell Gas Type Variability - Selenium Outlier Results

Cell Gas Type Variability - Arsenic

Digestion Type Variability - Selenium Outlier Results

Digestion Type Variability - Arsenic

Reported Detection Limits - Selenium

Reported Detection Limits - Arsenic

Method Variability Conclusions No statistically significant impact on mean selenium or arsenic concentration for any instrument/method variant CRC vs DRC vs QQQ Cell gas type Digestion type Outlier lab for Se – high bias EPA 3015A microwave digestion with dual mode CRC/DRC ICP-MS Reason for high bias under investigation Wide range of reported detection limits Arsenic (0.05 to 5.0 µg/L) Selenium (0.05 to 5.0 µg/L)

Study Conclusions & Recommendations

Study Conclusions Bottle type (HDPE vs. borosilicate glass) -- no significant differences for the study samples. Selenocyanate (SeCN), adsorbs strongly to HDPE container walls. Where SeCN is known or suspected to be present, borosilicate glass should be used to minimize selenium loss to bottle walls. Preservation with nitric acid and peroxide and closed- vessel digestion minimizes negative selenium bias for some biologically treated FGD wastewaters. Reported detection limits from some non-specialty commercial labs are not adequate to measure accurately below ELG limits.

Study Recommendations Use a closed vessel digestion approach to reduce loss of volatile selenium. Significantly lower concentrations of selenium and low MS/MSD recoveries were observed for some samples using open vessel digestion. Consider using ICP-QQQ-MS if arsenic is near regulatory limits. EPA has not evaluated a triple quadrupole instrument for use in CWA compliance monitoring; thus, acceptability as a modification to EPA Method 200.8 has not been determined for NPDES monitoring. Further evaluation of selenium digestion methods and arsenic instrumental methods is in progress.

Brooks Applied Labs, Bothell WA Acknowledgements Brooks Applied Labs, Bothell WA