EXPERIMENTAL DETERMINATION OF MINIMUM IGNITION CURRENT (MIC) FOR HYDROGEN /METHANE MIXTURES FOR THE DETERMINATION OF THE EXPLOSION GROUP CORRESPONDING.

Slides:



Advertisements
Similar presentations
VSD AND SS DRIVING ATEX MOTORS February Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions.
Advertisements

CHEMICAL AND PHASE EQUILIBRIUM (1)
Technological foresight methodology applied to forecast the future of hydrogen and fuel cells (EurEnDel project) Anna Oniszk-Popławska EC Baltic Renewable.
Workshop June, 19 th, 2006 – DLR, Paffenwaldring 38 – 40, Stuttgart ( parallel application of Blends Of Natural Gas and HYdrogen in internal combustion.
Fires and Explosions.
Proposal for a harmonized Battery Definition
Volkmar Schröder BAM, D Berlin Folie 1 International Conference on Hydrogen Safety, Pisa, September 8-10, 2005 Explosion Characteristics of Hydrogen-Air.
AZ HOD, LLC. Arizona Hydrogen on Demand Will Powe Jr.
On the Application of Artificial Intelligence Techniques to the Quality Improvement of Industrial Processes P. Georgilakis N. Hatziargyriou Schneider ElectricNational.
Laboratory Safety-Flammable Liquids Flammable Liquids and Fire Codes for Laboratories.
Funded by FCH JU (Grant agreement No ) 1 © HyFacts Project 2012/13 CONFIDENTIAL – NOT FOR PUBLIC USE 1.
Copyright © Flammable & Combustible Liquids.
Patrick Thornton, SNS/FPE June 9, 2008
HYDROGEN AND FUEL CELLS. WHAT IS HYDROGEN? Hydrogen is the simplest element. An atom of hydrogen consists of only one proton and one electron.
Industrial Prospective for Hydrogen Utilization - Safety Aspect - 10 September 2005 K.Takeno Mitsubishi Heavy Industries, Ltd. 添付 -2.
HOW TO DETERMINE EXPLOSIVE ATMOSPHERES Author: Mihai Magyari, Ph.D.Eng. INSEMEX PETROSANI ROMANIA G-ral. Vasile Milea Street, Petrosani, Hunedoara.
GHS CLASSIFICATION ONLINE. Registration: Click on “Register”
1 Hydrogen Economy Ryan Morrison ChE /20/2006 Methanol Economy vs.
Page 1 SIMULATIONS OF HYDROGEN RELEASES FROM STORAGE TANKS: DISPERSION AND CONSEQUENCES OF IGNITION By Benjamin Angers 1, Ahmed Hourri 1 and Pierre Bénard.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
Reproduction interdite © ALMA EUROPEAN CONSORTIUM Reproduction forbidden Design, Manufacture, Transport and Integration in Chile of ALMA Antennas Page.
Industrial Organization- Matilde Machado The Hotelling Model Hotelling Model Matilde Machado.
FLAMMABLES. 1. PROPERTIES OF FLAMMABLES Combustion (redox) reactions Solids, gases, most commonly liquids Fire Tetrahedron Ignition sources External-
CLP Up-date (The classification, labelling and packaging of chemical substances and mixtures) (DIRECTIVE 2008/112/EC OF THE EUROPEAN PARLIAMENT AND OF.
ADVANCE IN AUTOMOBILES HYDROGEN FUELLED ENGINES BY C.SUBRAMANIAN, 10MECH50, III-MECH, VCET,MADURAI.
In the 1970’s, scientists discovered the dangerous impact that CFC’s have in the Earth’s atmosphere. They were destroying the ozone layer which protects.
Automation and Drives A&D SD SM1, Hr. Mölter /62 Explosionsschutz_En_02_2004.ppt Standard Drives 3.2Classification of gases and vapors in explosion.
Fuel cells An electrochemical conversion device Chemical reactions cause electrons (current) to flow Requires a fuel, an oxidant and an electrolyte ( a.
12 V SoC – Monitoring - Assessment of Tolerances Audi AG WLTP-DTP-LabProcICE-105.
Power Plant Engineering
Proposal to introduce Grouping Criteria for the approval of replacement brake lining assemblies for L-category vehicles in UN Regulation No. 90 submitted.
Informations and comments on ECE-TRANS-WP.29-GRB e 1 Louis-Ferdinand PARDO (France) Transmitted by the expert from France Informal document GRB
Assessment of the Economic Impact of Greening Vehicular Transport in Barbados Winston Moore (PhD) and Stacia Howard Antilles Economics November 2015.
Bi-Weekly Safety Meeting November 29, The days of using canaries in mines as primitive gas detectors are long gone..they've been replaced by fixed.
Standards Certification Education & Training Publishing Conferences & Exhibits ISA SP12 Standards Related to Equipment in Hazardous Locations.
Atmospheric Monitoring. ATMOSPHERIC MONITORING INSTRUCTIONAL GOAL The participant will understand the need for atmospheric monitoring and the types, uses,
Innovation Energy Storage E.ON Innovation Center Energy Storage.
“Hydrogen detection apparatus” Dr. Ichiro Matsubara, convener
1 ATEX classification air motors, Dagmar Dübbelde ATEX CLASSIFICATION AIR MOTORS.
Development of Electrolysis System Powered by Solar-Cell Array to Supply Hydrogen Gas for Fuel-Cell Energy Resource Systems Priambodo, P; Yusivar, F; Subiantoro,
NONINCENDIVE INSTALLATIONS FOR CLASS I DIV 2 AREAS
Welding, Cutting and Brazing
Chapter 27 – Cells and Batteries
Dominik Franjo Dominković. , I. Bačeković, D. Sveinbjörnsson, A. S
Paper Review By Longxiang Liu Apr. 9, 2015
VAPOUR CLOUD EXPLOSIONS FROM THE IGNITION OF METHANE/HYDROGEN/AIR MIXTURES IN A CONGESTED REGION Mark Royle(1) Les Shirvill(2) and Terry Roberts(1) (1)
INTERNAL ENVIRONMENT ANALYSIS
Prediction of the Lift-off, Blow-out and Blow-off Stability Limits of Pure Hydrogen and Hydrogen/Hydrocarbon Mixture Jet Flames Wu, Y., Al-Rahbi, I. S.,
System Control based Renewable Energy Resources in Smart Grid Consumer
ME 475/675 Introduction to Combustion
THUM Adapter Impact on Hazardous Area Classification
Decree of the Ministry of Interior 3rd August 2015 The “so called” Italian Fire Prevention Code - IFC: S6 – Fire Control and Suppression provisions.
H2-O2 FUEL CELL By Mrs. Anuja Kamthe.
Dragon Breath Summary Paragraph Activity
ATEX fans st ATEX.
Achieving California's Renewable Energy Goals
A Safety Assessment of Hydrogen Supply Piping System by Use of FDS
CONSTRUCTION BS (BS 4533) K.F. Chan (Mr.) MEBS 6002.
Electrical Safety Standards
Principles of Natural Gas
Non-compatible chemicals
SUBMITTED BY : KAVINKUMAR.K KALAI SELVAN.U VIGNESHWARAN.G VINOTHKUMAR.M HYDROGEN FC VEHICLE GUIDED BY : Dr.B.VINOTH (ASS.PROF)/MECH.
Electrolysis Pass an electrical current through water and obtain H
M. Vanuzzo, M. Carcassi. Università di Pisa
Industrial Prospective for Hydrogen Utilization - Safety Aspect -
Flammable & Combustible Liquids
Advanced Air Pollution Engineering
Hazardous Area Classification
Fossil fuels Section 1.
Two Minute Drill – Residential 3
Presentation transcript:

EXPERIMENTAL DETERMINATION OF MINIMUM IGNITION CURRENT (MIC) FOR HYDROGEN /METHANE MIXTURES FOR THE DETERMINATION OF THE EXPLOSION GROUP CORRESPONDING TO IEC 60079-20-1 STANDARD Agnès JANÈS, Jérôme LESAGE, Benno WEINBERGER, Douglas CARSON, Bruno DEBRAY

Intermittent electricity Electrolysis & storage « Power to Gas » – one flexible solution Value of green electricity as chemicals, H2 or CH4 Mobility Take advantage of low price of electricity on the markets, caused by overproduction of intermittent electricity at low marginal cost, to produce add value gas fuels (hydrogen or methane synthesis) which can be easily stored and transported in the existing natural gas infrastructures. Residential Intermittent electricity Electrolysis & storage Admix NG or Methnation Distribution & Transport network NG H2 NG+H2 CO2 H2 CH4 Industry NG grid stakeholders expect that blends up to 20% seem to be a realistic scenario.

Choice of equipment - ATEX regulation => The knowledge of the gas group for these hydrogen/NG (H2NG) mixtures is a necessary information for the choice of equipment and protective systems intended for the use in potentially explosive atmospheres

IEC 60079-20-1 standard propose two methods to classify in a gas group 1st Method: determination of maximum experimental safe gap (MESG) The MESG of flammable gases and vapors is the lowest value of the safe gap measured according to IEC 60079-20-1 The MESG is measured in mm Gas

2nd method: determination of minimum ignition current (MIC) ratio The experimental device consists of a spark test apparatus and an explosion chamber that is filled continuously with the gas to be tested The MIC ratio results are dimensionless, obtained by dividing the MIC of gas tested by the value of MIC of pure methane Electrode holder Cadmium disc Used spark test apparatus compliant to Annex B of IEC 60079-11 standard

(1) Criteria used for classification of gases in gas groups according to IEC 60079-20-1 Classification based on MESG Group IIA: MESG ≥ 0.9 mm Group IIB: 0.5 mm < MESG < 0.9 mm Group IIC: MESG ≤ 0.5 mm Classification based on MIC Group IIA: MIC ratio > 0.8 Group IIB: 0.45 ≤ MIC ratio ≤ 0.8 Group IIC: MIC ratio < 0.45 Cases for which the determination both MESG and MIC values is required Group IIA: 0.8 ≤ MIC ratio ≤ 0.9 Group IIB: 0.45 ≤ MIC ratio ≤ 0.5 Group IIC: 0.5 mm ≤ MESG < 0.55 mm

(2) Criteria used for classification of gases in gas groups according to IEC 60079-20-1 => These criteria indicate that exclusively MIC ratio values are sufficient to assign a gas mixture into a gas group for the following cases: Group IIA: MIC ratio > 0.9 Group IIB: 0.5 ≤ MIC ratio ≤ 0.8 Group IIC: MIC ratio < 0.45 Concerning the case of methane/hydrogen mixtures, the IEC 60079-20-1 standard gives the following statement to determine the gas group: Natural gas is classified as Group IIA, for less than 25 vol.% of hydrogen The threshold of 25 vol.% hydrogen is validated by several MESG measurements in literature, but no so with the MIC ratio. Therefore the main aim of this work was the experimental determination of MIC and MIC ratios, with respect to the MIC of pure methane, of methane/hydrogen mixtures up to 20 vol.% of hydrogen.

MIC ranges obtained on methane/hydrogen mixtures tested The MIC measurements were performed on each of the 10 methane/hydrogen mixtures containing from 2 to 20 vol.% of hydrogen.

MIC ratio, as a function of hydrogen content in the methane/hydrogen mixtures The linear least squares regression shows a very good correlation between the MIC ratio and the hydrogen content in the methane/hydrogen mixture

Conclusion The application of gas classification criteria in terms of MIC ratio from IEC 60079-20-1 standard leads to the following classification: Methane/hydrogen mixtures containing 2, 4 and 6 vol.% of hydrogen: Group IIA, as MIC ratio is greater than 0.9, Methane/hydrogen mixtures containing 8, 10, 12 and 14 vol.% of hydrogen: the determination of MESG is necessary to conclude if these mixtures are classified in Group IIA or IIB, as MIC ratio is comprised between 0.8 and 0.9 Methane/hydrogen mixtures containing 16, 18 and 20 vol.% of hydrogen: Group IIB, as MIC ratio is lower than 0.8. => The last result appears in contradiction with the statement of IEC 60079-20-1, providing a classification in Group IIA up to 25 vol.% of hydrogen. Therefore the IEC TC 31 decided a campaign of MIC ratio in different labs to adapt the future standard IEC 80079-20-1 replacing the IEC 60079-20-1