Earthing of MV and LV Distribution Systems: A multi-faceted problem.

Slides:



Advertisements
Similar presentations
Bonding and Grounding What? Why? How?
Advertisements

SITOP select Automation and Drives SITOP select Electronic Diagnosis Module Fault diagnosis – rapid and reliable.
Speaker Scott Whaley - EIT Protecting & Ice Melting Westmans Distribution Lines.
Mobile Radiographic Equipment. Introduction In-patients who could not leave their beds In-patients who could not leave their beds Surgeons who required.
Electrical Installation
Programme Tx / Dx Demarcation Feb 08. Programme Topics cover in this presentation Back Ground Existing and future MTS substations Lines.
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
Chapter 12 Transformers. Chapter 12 Transformers.
Electricity & Electronics
Committed to connecting the world Ninth ITU Symposium on ICTs, the Environment and Climate Change Kochi, India, 15 December 2014 Damage prevention and.
Bonding Requirements For Gas Piping Systems Bob Torbin October 2007
EE4503 Electrical Systems Design
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
Chapter : 7 : Mains Electricity
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
Electrical Systems Electrical Engineering in Railways –Rolling Stock –Communications & Control –Signalling –LV Installations in Stations and Buildings.
Bonding, Grounding and the NEC  Presented by The National Association of Certified Home Inspectors
Electrical Earthing D.K.Pathirana. Applications of earthing Protect human against lightning and earth fault condition Protect the premises against lightning.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
By Carlin Bright. Electricity The flow of electrons in a conductor.
Calculating Separation Distance and Surge Current
Generating and Using Electricity
Pole Mounted Switch Disconnector NPS
PSerc Lightning Protection: A Stroke of Luck? Theory and Application: Customer Side Low Voltage Systems Ward Jewell Wichita State University APPA 2005.
Mains electricity Revise the following Direct and alternating current 3-pin plugs and electrical cable Safety – fuses and earth wire Period and frequency.
IEEE Wind Farm Collector System Grounding for Personal Safety Summary of Topics.
What makes substation work?
Grounding, bonding, and ground fault currents
SWER New Zealand & Australian Experience
MAINS ELECTRICITY. Specification Electricity Mains electricity understand and identify the hazards of electricity including frayed cables, long cables,
MONFILS Pierre-André (BE) Barcelona May 2003 One phase rural distribution installation with direct connection to HV trunk line P.A. MONFILS, Jean-Louis.
“Zip Zap”. Electrical Safety Charges What is a Circuit? An electric circuit consists of: –A source of electrical energy (battery or cell) –A user.
Typical Telecommunications Network
ELECTRICITY IN THE HOME. Parallel Connections of Domestic Appliances Electricity boards distribute power to separate households using a pair of thick,
Utility Engineers, PC.  Generation  Transmission  Distribution.
POWER HOUSE.
Submitted to: Submitted by:
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
Submitted to: Submitted by:
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
ON 400 KV GSS RAISER JAIPUR ROAD ,BIKANER
132KV GSS PIPAR CITY JODHPUR
Submitted To:- Submitted By:- Mr.
Testing of Low Voltage Installations
A PRESENTATION On 400KV GSS SURPURA JODHPUR
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
ITU Symposium on ICTs, the Environment and Climate Change Kuala Lumpur, Malaysia 21 April 2016 Session2: Damage prevention and safety Resistibility of.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
ELECTRICAL INSTRUMENTS ( service and utilization )
FUSES explaining how fuses work fuses and earthing choosing the
P2 - Physics Mains Electricity
AUTOMATIC CIRCUIT RECLOSER
6 Week industrial Training Presentation
Protection of Power Systems
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
PROTECTION AGAINST INDIRECT CONTACT
Circuit Protection Unit 9.
EE6501 POWER SYSTEM ANALYSIS
Basics of electrical engineering
BY Presenter Name: G.V,Reddy DESIGNATION: Sr. General Manager
Engineering Project Cable Management.
EHV Transmission Equipments
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
EET 323 – Electrical System Design Lecture 9: Grounding
MAINS ELECTRICITY.
P2 - Physics Mains Electricity.
Electrical components and systems
Grounding Myths.
Presentation transcript:

Earthing of MV and LV Distribution Systems: A multi-faceted problem. Hendri Geldenhuys Gareth Stanford Industry Association Resource Centre (IARC) Eskom

Considerations related to: Public , Customer (end user?) And Line’s man safety considerations Merged with System “protection” and performance considerations

MV Line LV Feeder Distribution transformer LV Earth MV Earth Service Box Service connection Communication line Artwork: A Dickson

Design Philosophy Consider the Bonding and Earthing of the structure: There are no single solution that fits all applications and environmental conditions All solutions has risk, some less than others,

Design Philosophy Wood, LV Feeder MV Feeder Telephone Wood, Concrete or Steel MV Feeder Wood, Concrete LV Feeder or Steel Telephone

Design Philosophy BIL wires on all shared structures (no gap no insulation of BIL wire.) BIL wires only on suspension structures with no stays (no gap no insulation of BIL wire.) No BIL wire BIL wire on all shared structures- insulate bottom 2m of down wire No BIL wire- Double arresters on transformers on MV side BIL wires on all – Move gap down below LV BIL wires on all – Split air gap above & below LV to prevent LV Faults

BIL wire on all shared structures (no gap no insulation of BIL wire.) LV Feeder MV Feeder Telephone Wood, Concrete or Steel MV Feeder LV Feeder Telephone

(no gap no insulation of BIL wire.) BIL wires only on suspension structures with no stays (no gap no insulation of BIL wire.) LV Feeder MV Feeder Telephone Wood, Concrete or Steel MV Feeder LV Feeder Telephone

No BIL wire LV Feeder MV Feeder Telephone Wood, Concrete or Steel

BIL wire on all shared structures- insulate bottom 2m of down wire LV Feeder MV Feeder Telephone Wood, Concrete or Steel MV Feeder LV Feeder Telephone

Double arresters on transformers on MV side No BIL wire- Double arresters on transformers on MV side LV Feeder MV Feeder Telephone Wood, Concrete or Steel MV Feeder LV Feeder Telephone

BIL wires on all – Move gap down below LV LV Feeder MV Feeder Telephone Wood, Concrete or Steel MV Feeder LV Feeder Telephone

BIL wires on all – Split air gap above & below LV to prevent LV Faults LV Feeder MV Feeder Telephone Wood, Concrete or Steel MV Feeder LV Feeder Telephone

Safety Risks That occurs in MV LV Distribution Systems

Separate MV and LV Earths FEEDER LINE ( 3Ph , Ph-Ph or SWER ) TANK fuses SURGE ARRESTOR + 242 V - 242 V N HV TO LV NEUTRAL ARRESTOR L N E MV EARTH LV EARTH

MV Voltage Transferred to LV Earth FEEDER LINE ( 3Ph , Ph-Ph or SWER ) TANK fuses SURGE ARRESTOR + 242 V - 242 V N > 5 kV HV TO LV NEUTRAL ARRESTOR > 5 kV L N E MV EARTH LV EARTH

MV-LV Supply System L N E N L N E

MV-LV Supply System L N E N 2.5 kW 10A 20A -100V 100V LV Neutral Break

LV MV 161 V [ =230 x (70/100) ] I = 2.3 A 69 V [ =230 x (30/100) ] Neutral SA ☻The ratio between the MV and LV earth electrode resistance determine the voltage on the LV neutral- earth 70 Ω 30 Ω Step potential

Equipment Damage

5 x Iph

Earthing and Bonding in different Environments Pollution Low Pollution High Lighting Low No BIL down wire or bonding of hardware Bonding of hardware (no BIL down wire) Lighting High BIL wire and co-ordinated gap Bonding of total structure, no gap, high insulator BIL.

MV Line LV Feeder Distribution transformer LV Earth MV Earth Service Box Service connection Communication line Artwork: A Dickson

AC power system related risk Design Philosophy MV Conductor drop onto LV system MV conductor contact to BIL down wire only LV contact to BIL down wire BIL wires on all shared structures (no gap no insulation of BIL wire.) Fast clearing of MV fault (1sec). Auto Reclose repeat to lock out. High GPR on LV Protective Earth. Exposure to all LV installations and BIL wire locations Med risk Slow clearing of fault (10 sec) even a small risk of not clearing fault. Very High GPR on BIL wire. Fault not cleared BIL wire stay live High risk BIL wires only on suspension structures with no stays (no gap no insulation of BIL wire.) Fewer BIL wires stay live No BIL wire Exposure to all LV installations No risk BIL wire on all shared structures- insulate bottom 2m of down wire BIL wire not accessible No BIL wire- Double arresters on transformers on MV side BIL wires on all – Move gap down below LV BIL wire will remain live until it flashes to LV protective earth. If Fault to LV occurs-clearing of the fault is the same as column to the left. Low risk BIL wires on all – Split air gap above & below LV to prevent LV Faults

Public&Consumer lightning risk Design Philosophy Effective earth Public&Consumer lightning risk Equipment Damage BIL wires on all shared structures (no gap no insulation of BIL wire.) MV earth + LV earth +BIL wire earths. Best practice (not totally safe) Best Practice BIL wires only on suspension structures with no stays (no gap no insulation of BIL wire.) MV earth + LV earth +fewer BIL wires No BIL wire MV earth+ LV earth only High risk BIL wire on all shared structures- insulate bottom 2m of down wire MV earth + LV earth only No BIL wire- Double arresters on transformers on MV side MV earth + LV earth +BIL earths Medium risk BIL wires on all – Move gap down below LV MV earth + LV earth + BIL earths BIL wires on all – Split air gap above & below LV to prevent LV Faults

Overall Risk 2 MED 3 MED 1 MED AC power risk Lightning Risk Design Philosophy MV Conductor drop onto LV system MV conductor contact to BIL down wire only LV contact to BIL down wire BIL wires on all shared structures (no gap no insulation of BIL wire.) MED HIGH LOW BIL wires only on suspension structures with no stays (no gap no insulation of BIL wire.) No BIL wire BIL wire on all shared structures- insulate bottom 2m of down wire 2 MED No BIL wire- Double arresters on transformers on MV side BIL wires on all – Move gap down below LV 3 MED BIL wires on all – Split air gap above & below LV to prevent LV Faults 1 MED

LV Feeder MV Feeder Telephone MV Feeder LV Feeder Telephone 50 mm LV gap 500 mm BIL wood MV Feeder 500 mm BIL wood gap LV Feeder 50 mm LV gap Telephone

Designs can be optimised for specific areas and applications A (simple) Wood Pole Structure has complex safety and performance considerations Designs can be optimised for specific areas and applications No Power System is ever 100% safe

Safe and Reliable