Comments on Linear Collider Calorimetry Case for Precision ECAL?

Slides:



Advertisements
Similar presentations
Peter Schleper, Hamburg University SUSY07 Non-SUSY Searches at HERA 1 Non-SUSY Searches at HERA Peter Schleper Hamburg University SUSY07 July 27, 2007.
Advertisements

Lauri A. Wendland: Hadronic tau jet reconstruction with particle flow algorithm at CMS, cHarged08, Hadronic tau jet reconstruction with particle.
PFA-Enhanced Dual Readout Crystal Calorimetry Stephen Magill - ANL Hans Wenzel - FNAL Outline : Motivation Detector Parameters Use of a PFA in Dual Readout.
Jet and Jet Shapes in CMS
Testbeam Requirements for LC Calorimetry S. R. Magill for the Calorimetry Working Group Physics/Detector Goals for LC Calorimetry E-flow implications for.
Recent Electroweak Results from the Tevatron Weak Interactions and Neutrinos Workshop Delphi, Greece, 6-11 June, 2005 Dhiman Chakraborty Northern Illinois.
1 Measurement of f D + via D +   + Sheldon Stone, Syracuse University  D o D o, D o  K -  + K-K- K+K+ ++  K-K- K+K+ “I charm you, by my once-commended.
1 Hadronic In-Situ Calibration of the ATLAS Detector N. Davidson The University of Melbourne.
PFA Development – Definitions and Preparation 0) Generate some events w/G4 in proper format 1)Check Sampling Fractions ECAL, HCAL separately How? Photons,
Energy Flow Studies Steve Kuhlmann Argonne National Laboratory for Steve Magill, U.S. LC Calorimeter Group.
Energy Flow Studies Steve Kuhlmann Argonne National Laboratory for Steve Magill, Brian Musgrave, Norman Graf, U.S. LC Calorimeter Group.
Application of Neural Networks for Energy Reconstruction J. Damgov and L. Litov University of Sofia.
Click to edit Master title style IEEE short course on: Calorimetry Calorimeter systems at collider experiments Erika Garutti (DESY)
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Study of a Compensating Calorimeter for a e + e - Linear Collider at Very High Energy 30 Aprile 2007 Vito Di Benedetto.
PPARC forum on developments in scintillator technology R M Brown - RAL 1 Scintillating Crystals for Particle Physics Outline  Performance considerations.
Progress with the Development of Energy Flow Algorithms at Argonne José Repond for Steve Kuhlmann and Steve Magill Argonne National Laboratory Linear Collider.
W properties AT CDF J. E. Garcia INFN Pisa. Outline Corfu Summer Institute Corfu Summer Institute September 10 th 2 1.CDF detector 2.W cross section measurements.
Heavy Scintillating Crystal Fibers for calorimetry
Valery Dormenev Institute for Nuclear Problems, Minsk
Jet Energy Scale at CMS Anwar A Bhatti June 8, 2006 XII International Conference on Calorimetry Chicago IL, USA.
Event Reconstruction in SiD02 with a Dual Readout Calorimeter Detector Geometry EM Calibration Cerenkov/Scintillator Correction Jet Reconstruction Performance.
1 Energy loss correction for a crystal calorimeter He Miao Institute of High Energy Physics Beijing, P.R.China.
María Cepeda (CIEMAT, Madrid) Valencia, II CPAN days 1.
P ARTICLE D ETECTORS Mojtaba Mohammadi IPM-CMPP- February
Development of a Particle Flow Algorithms (PFA) at Argonne Presented by Lei Xia ANL - HEP.
25 sep Reconstruction and Identification of Hadronic Decays of Taus using the CMS Detector Michele Pioppi – CERN On behalf.
May 1-3, LHC 2003V. Daniel Elvira1 CMS: Hadronic Calorimetry & Jet/ Performance V. Daniel Elvira Fermilab.
Pandora calorimetry and leakage correction Peter Speckmayer 2010/09/011Peter Speckmayer, WG2 meeting.
Coil and HCAL Parameters for CLIC Solenoid and Hadron-calorimetry for a high energy LC Detector 15. December LAPP Christian Grefe CERN.
Positional and Angular Resolution of the CALICE Pre-Prototype ECAL Hakan Yilmaz.
PFAs – A Critical Look Where Does (my) SiD PFA go Wrong? S. R. Magill ANL ALCPG 10/04/07.
1 D.Chakraborty – VLCW'06 – 2006/07/21 PFA reconstruction with directed tree clustering Dhiman Chakraborty for the NICADD/NIU software group Vancouver.
1 1 - To test the performance 2 - To optimise the detector 3 – To use the relevant variable Software and jet energy measurement On the importance to understand.
Search for Extra Dimensions in diphotons at CMS Duong Nguyen Brown University USLOU Meeting Fermilab, Oct , 2010.
24/08/2009 LOMONOSOV09, MSU, Moscow 1 Study of jet transverse structure with CMS experiment at 10 TeV Natalia Ilina (ITEP, Moscow) for the CMS collaboration.
Abstract Several models of elementary particle physics beyond the Standard Model, predict the existence of neutral particles that can decay in jets of.
Jet Studies at CDF Anwar Ahmad Bhatti The Rockefeller University CDF Collaboration DIS03 St. Petersburg Russia April 24,2003 Inclusive Jet Cross Section.
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
Dijet Mass and Calibration1 H C A L Z(700) Data and Calibration Dan Green Fermilab June, 2001.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
LHC Symposium 2003 Fermilab 01/05/2003 Ph. Schwemling, LPNHE-Paris for the ATLAS collaboration Electromagnetic Calorimetry and Electron/Photon performance.
First Measurement of Jets and Missing Transverse Energy with the ATLAS Calorimeter at and David W. Miller on behalf of the ATLAS Collaboration 13 May 2010.
PbWO 4 crystals Calorimeter Liping Gan University of North Carolina Wilmington.
David Hitlin Frascati SuperB Workshop March 16/17, 2006 An EMC for Super B  With the likely time structure of SuperB, backgrounds and radiation damage.
International Workshop on Linear Collider, Jeju, Korea, Ren-yuan Zhu, Caltech Aug. 27, Comments on Linear Collider Calorimetry Case for Precision.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
On behalf of the Acfa-Sim-J Group
Lecture 8 – Detectors - II
Lecture 18 - Detectors Detector systems
Electroweak physics at CEPC
Particle detection and reconstruction at the LHC (IV)
SuperB R&D Meeting David Hitlin February 14, 2008
Studies with PandoraPFA
Study of Gamma+Jets production
Mickey Chiu University of Illinois at Urbana-Champaign
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Status of ECAL Optimization Study
A New Measurement of |Vus| from KTeV
EFA/DHCal development at NIU
LSO/LYSO Crystals for Future High Energy Physics Experiments
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Top Quark Production at the Large Hadron Collider
Plans for checking hadronic energy
Argonne National Laboratory
Detector Optimization using Particle Flow Algorithm
Status of CEPC HCAL Optimization Study in Simulation LIU Bing On behalf the CEPC Calorimeter working group.
Installation, Commissioning and Startup of ATLAS & CMS Experiments
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
Measurement of b-jet Shapes at CDF
Presentation transcript:

Comments on Linear Collider Calorimetry Case for Precision ECAL? Ren-yuan Zhu California Institute of Technology Jun 28, 2002

Introduction While all recent built HEP detectors have precision ECAL, LC calorimetry community pursues precision jet calorimetry. A sexy solution is the energy flow, which requires “particle reconstruction in jets” and thus calorimeter with fine segmentations. Jet and jet-jet mass measurements suffer from systematic uncertainties from physics (QCD and fragmentation), algorithm (jet definition) and detector (resolution and leakage). While the limit to the precision ECAL is well understood the limit to the jet measurement at LC is yet to be fully investigated. Jun 28, 2002

What is Energy Flow Jet energy is not well measured by calorimeter. At LC energies, energy of isolated charged calorimeter cluster may be replaced by better measured matching tracker momentum. For overlapping clusters, classical energy flow subtracts average response: 30% improvement. Modern energy flow tries to subtract exact deposition. Jun 28, 2002

Energy Flow at L3: Z Mass at LEP I Proceedings of Sitges Workshop, p.1058, 1999 Classical energy flow improves Z mass resolution from 10 to 7%: 30% improvement Similar improvement observed in all 4 LEP experiments. See presentations in Calor2002. Jun 28, 2002

CDF Energy Flow: Jet Energy Photon + Jets by CDF, using shower maximum (particle ID) and tracker: 24% improvement. U. Baur et al., Fermilab-Pub-001297, 2000. Jun 28, 2002

CMS Energy Flow: Jet Energy S. Kunori, Talk in Calor2002 Res.: 24 to 14% @ 20 GeV, 12 to 8% @ 100 GeV ET Scale: < 2% in 20 — 120 GeV Calo: no corrections; 1: simple average; 2: shower library; 3: library, track-cluster match, out cone track; 4: out cone track only. Jun 28, 2002

Best Jet Mass Resolution at LEP II W Mass with 2 jets by L3: 3% Higgs with 2 jets at LEP: 3% 4C Fit using Jet direction: calorimetry resolution irrelevant. Jun 28, 2002

Comparison of Stochastic Term a L3 CDF CMS Calorimeter 97% 83% 107-120% Energy Flow 65% 64% 63-80% 4C Fit 26% Jun 28, 2002

“Theoretical Limit” of Energy Flow V. Morgunov, Talk in Calor2002 100% charged track replacement is impossible because of shower overlap. Additional uncertainty due to physics and jet definition. Optimization of detector design must be done after full investigation of all contributions. Jun 28, 2002

Solution for Shower Overlap? V. Morgunov, Talk in Calor2002 R. Wigmans: Shower overlap is unavoidable, and fine segmentation does not help. Attempt by CDF and CMS indicates that shower library and particle ID with shower maximum detector for overlap shower do not help. Jun 28, 2002

Jet Mass Resolution in Hadron Collider D. Green, Talk in Calor2002 Monte Carlo studies identify the elements contributing to the mass error. Quote low PT, Z -> JJ. dM/M ~ 13% without FSR. FSR is the biggest effect. The underlying event is the second largest error (if cone R ~ 0.7). Calorimeter resolution is a minor effect. Algorithm HCAL Resolution Physics Jun 28, 2002

Energy Flow Summary Classical energy flow improves jet energy resolution by 30%, to 60% stochastic term. Any further improvement must also address the physics limitations. The energy flow is less effective at high energies: tracker resolution & shower overlap. Jet direction is better measured. Less than 30% stochastic term is already achieved by using 4C fit, which is also available free at LC. Before spending tax payer’s money in calorimeter segmentation, full simulation and verification with test beam are required to understand limitations to the jet measurement. Jun 28, 2002

Why Precision ECAL at LC Photons and electrons are fundamental particles for SM and new physics. Performance of precision ECAL, such as crystals, well understood: Good energy, position and photon angular resolution; Good e/photon identification and reconstruction efficiency; Good missing energy resolutions; Good jet energy resolution with energy flow. Jun 28, 2002

SM Physics in Precision ECAL Charmonium System Observed Through Inclusive Photons Charmed Meson in Z Decay Crystal Ball Jun 28, 2002

New Physics in Precision ECAL J. Gunion, in Snowmass SUSY Breaking with Gravitino CMS Jun 28, 2002

New Physics in Precision ECAL (Cont.) The CDF event: 2 e + 2 γ + ETmiss SM expectation (WWγγ) ~ 10-6 (PR D59 1999) Possible SUSY explanation L3 should be able to observe Another possible channel Jun 28, 2002

BaBar CsI(Tl) Resolution Crystal Calorimetry at Low Energies Good light yield of CsI(Tl) provides excellent energy resolution at B factory energies Jun 28, 2002

“Radiative”+Intrinsic L3 BGO Resolution Contribution “Radiative”+Intrinsic Temperature Calibration Overall Barrel 0.8% 0.5% 1.07% Endcaps 0.6% 0.4% 0.88% Jun 28, 2002

CMS PWO Resolution Crystal Calorimetry at High Energies Beam Test Crystal Calorimetry at High Energies Designed Resolution Jun 28, 2002

KTeV CsI Position Resolution Sub mm position resolution is achievable. L3 BGO & CMS PWO: 0.3 mm at high energies. Jun 28, 2002

Properties of Crystal Scintillators NaI(Tl) CsI(Tl) CsI BaF2 BGO PbWO4 LSO(Ce) GSO(Ce) Density (g/cm3) 3.67 4.51 4.89 7.13 8.3 7.40 6.71 Melting Point (ºC) 651 621 1280 1050 1123 2050 1950 Radiation Length (cm) 2.59 1.85 2.06 1.12 0.9 1.14 1.37 Molière Radius (cm) 4.8 3.5 3.4 2.3 2.0 2.37 Interaction Length (cm) 41.4 37.0 29.9 21.8 18 21 22 Refractive Index a 1.79 1.95 1.50 2.15 2.2 1.82 Hygroscopicity Yes Slight No Luminescence b (nm) (at peak) 410 560 420 310 300 220 480 440 Decay Time b (ns) 230 1300 35 6 630 50 10 40 60 Light Yield b,c (%) 100 45 5.6 2.7 9 0.1 0.6 75 30 d(LY)/dT b (%/ ºC) ~0 0.3 -0.6 -2 -1.6 -1.9 ? Volume Price ($/cm3) 1 to 2 2 2.5 7 - a. at peak of emission; b. up/low row: slow/fast component; c. measured by PMT of bi-alkali cathode. Jun 28, 2002

Summary: Crystal Calorimetry for LC To maximize physics reach, calorimetry for LC should have precision measurement on electrons, photons and jets. The crystal calorimetry provides the best achievable EM resolution, good missing energy and jet resolution. Some heavy crystal scintillators may provide a cost effective precision EM calorimeter solution. Jun 28, 2002