DASD Explorer Training

Slides:



Advertisements
Similar presentations
Chapter 6 Computer Architecture
Advertisements

MVS/ESA Fundamentals of VSAM © Copyright IBM Corp., 2000, All rights reserved.
©HCCS & IBM® 2008 Stephen Linkin1 Mainframe Hardware Systems And High Availability Stephen S. Linkin Houston Community College © HCCS and IBM 2008.
1 Storage Hierarchy Cache Main Memory Virtual Memory File System Tertiary Storage Programs DBMS Capacity & Cost Secondary Storage.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 2: Managing Hardware Devices.
Measuring Performance Chapter 12 CSE807. Performance Measurement To assist in guaranteeing Service Level Agreements For capacity planning For troubleshooting.
Intelligent Storage Systems
Introduction to the new mainframe: Large-Scale Commercial Computing © Copyright IBM Corp., All rights reserved. Chapter 6: Accessing large amount.
6. The CPU and Memory Chapt. 7.
© 2009 EMC Corporation. All rights reserved. Intelligent Storage Systems Module 1.4.
Operating System & Application Files BACS 371 Computer Forensics.
2730/2730T/5730 Performance Comparison 20 May 2008.
OS and Application Files BACS 371 Computer Forensics.
Stephen Linkin Houston Community College January 15, 2007 © Mike Murach & Associates, HCC, IBM 1 Introduction To IBM Mainframe Systems Chapter.
© 2011 IBM Corporation 11 April 2011 IDS Architecture.
Module 10 Configuring and Managing Storage Technologies.
1 File Systems Chapter Files 6.2 Directories 6.3 File system implementation 6.4 Example file systems.
Analysis of Virtual Tape Subsystems Ned Diehl The Information Systems Manager, Inc NCACMG Vienna, Virginia.
Storing Data On Your Computer Chapter 12, Exploring the Digital Domain.
Computers Central Processor Unit. Basic Computer System MAIN MEMORY ALUCNTL..... BUS CONTROLLER Processor I/O moduleInterconnections BUS Memory.
Understanding and Troubleshooting Your PC. Chapter 5: Understanding, Installing, and Troubleshooting Disk Drives2 Chapter Objectives  In this chapter,
To CUP, or Not To CUP? That is the (FICON) Question! Dr. Steve Guendert Global Solutions Architect, System z Techologies CMG Philadelphia Sept 2009.
Disks Chapter 5 Thursday, April 5, Today’s Schedule Input/Output – Disks (Chapter 5.4)  Magnetic vs. Optical Disks  RAID levels and functions.
Introduction to the new mainframe: z/OS basics © Copyright IBM Corp., All rights reserved. Chapter 19 Hardware systems and LPARs.
Components of a Sysplex. A sysplex is not a single product that you install in your data center. Rather, a sysplex is a collection of products, both hardware.
Chapter 8 External Storage. Primary vs. Secondary Storage Primary storage: Main memory (RAM) Secondary Storage: Peripheral devices  Disk drives  Tape.
Introduction to Software Project Estimation I (Condensed) Barry Schrag Software Engineering Consultant MCSD, MCAD, MCDBA Bellevue.
© 2011 IBM Corporation Sizing Guidelines Jana Jamsek ATS Europe.
Disk & File System Management Disk Allocation Free Space Management Directory Structure Naming Disk Scheduling Protection CSE 331 Operating Systems Design.
IO_for System Z Basics: The channel subsystem directs the flow of information between I/O devices and main storage. It relieves CPUs of the task of communicating.
Click to add text Introduction to the new mainframe: Large-Scale Commercial Computing © Copyright IBM Corp., All rights reserved. Chapter 6: Accessing.
Chapter 3: Where are programs and data Stored?. How important is this chapter to understanding how a computer works? 7 (on a scale of 1-10 with 10 being.
Managing Hardware Devices Facilitator: Suleiman Mohammed(mcpn, mncs) Institute of Computing & ICT, Ahmadu Bello University, Zaria.
TS7700 Performance and Capacity Daily and Hourly charts Enter Description, Month & Year in this Text Box.
Click to add text © 2004 IBM Corporation IBM ^ z/VM Basic Structures and Commands Control Program.
File organization Secondary Storage Devices Lec#7 Presenter: Dr Emad Nabil.
System Storage TM © 2007 IBM Corporation IBM System Storage™ DS3000 Series Jüri Joonsaar Tartu.
Monitoring Storage Systems for Oracle Enterprise Manager 12c
TS7700 Virtualization Engine ) Configuration of
Database Management Systems (CS 564)
Direct Attached Storage and Introduction to SCSI
Chapter 3 Top Level View of Computer Function and Interconnection
Direct Attached Storage Overview
Monitoring Storage Systems for Oracle Enterprise Manager 12c
Part V Memory System Design
Chapter 19 Hardware systems and LPARs
Direct Attached Storage and Introduction to SCSI
XtremIO Storage Array Asset Profile
Unity Storage Array Profile
XINFO – Scanner zOS - Space
Device Management Damian Gordon.
Business Office Manager Training The ACH Process in 7 Steps
Assessment Findings System Professional <Insert Consultant Name>
UP-R-APDRP HV – MRI Billing
ECEG-3202 Computer Architecture and Organization
Dataset Explorer Training
Today’s agenda Hardware architecture and runtime system
Chap. 12 Memory Organization
Presentation & Demo August 7, 2018 Bill Shelden.
Overheads for Computers as Components 2nd ed.
Overview: File system implementation (cont)
CPU Explorer Training 2014.
File Storage and Indexing
Database Internals: How Indexes Work
Specialized Cloud Architectures
File System Implementation
Database administration
William Stallings Computer Organization and Architecture 7th Edition
Presentation transcript:

DASD Explorer Training 2014

DASD Explorer “Collect DASD information and save into historical views”

Data Source Record Description RMF 70 CPU Activity RMF 73 Channel – channel path activity RMF 74.1 Device – Front-end response times RMF 74.5 Cache - Activity inside the storage RMF 78.3 LCU – Hyper-PAV and LCU activity DCOLLECT “V” DASD occupation ** DASD configuration discovery

Historical views Target Table name Description CACHE History cacheHist Storage Group and SSID activity: cache hits, response times CACHE Volume History cacheVolumes Volume level cache activity Channel CEC History chpCec CEC totals, zHPF activity Channel Lpar History chpLpar CHPID activity per LPAR Device History devHist Storage Group and SSID: SSCH, response times per LPAR Device Volume History devVolumes Volume level activity LCU History lcuHist Hyper-PAV and LCU activity LCU Config History cfgLcuHist Configuration matrix Volume Config History cfgVolHist Volume configuration matrix Volume History volHist Volume occupation

Cache Activity Activity inside the box (storage array) Fields Storage Array Storage Group SSID Activity inside the box (storage array) The counters accounts the usage per all LPAR’s ¼ of Cache Volumes space

Cache Activity counters Counters available: XRC = Asynchronous replication counters zHPF = Hiper FICON activity

Cache operations Cache operations: %random read hits and %random read misses, %random writes, %sequential reads and %sequential writes

IOPS x Response time IO activity per hour of day: average, minimum, maximum and STDEV And average response time

Device Activity Front-end activity (LPAR view): Fields SID Sysplex SystemName Storage Array Storage Group LCU Tag Unit Cylinders Front-end activity (LPAR view): I/O’s per second (IOPS) Response times: connected, disconnected, pending, CMR Queuing delays PAV activity (not Hyper-PAV)

Device Activity counters Counters available:

Response time components Connect, disconnect and pending time components vs IOPS

Channel Activity (LPAR) Fields SID Sysplex SystemName CHPID CSSID Channel Acron Channel type Measure the activity on the channels: Number of read and writes MB/s transferred

Channel activity Channel activity: MB/s read and MB/s writes

CEC Channel Activity FICON and Hiper-FICON (zHPF) Fields CEC name CHPID CSSID Channel Acron Channel type FICON and Hiper-FICON (zHPF) Total activity per CHPID

LCU Configuration Configuration history matrix: Fields CEC name Sysplex SID System name LCU CHPID CSSID CU number Channel acron Channel type Storage Array Tag SSID Configuration history matrix: Built from RMF 70-78 records

Volume Configuration Volume configuration matrix: Fields Volser SID Sysplex System name Storage Array Storage Group Device number LCU Tag Unit Device type Unit type Cylinders Volume configuration matrix:

Config Explorer Crossing information on RMF 70-78 records, we build explorers for each view:

Volume Allocation History based on DCOLLECT “V” records Fields Volser Storage Group Storage Array Tag Unit Device type Manufacture Cylinders

DASD Discovery Interrogates the z/OS and build a DASD configuration

DASD Discovery Device information: VOLSER Channel paths CDR information Space information DCOLLECT information “Build the DASD infra-structure from this information.”

Volume Identity Volume identity : Identified by the Configuration Data Record (CDR) DEVNUM TAG VOLSER 002107.932.IBM.82.0000000DT971.0100 Type number 002107 Model number 932 Manufacture IBM Plant 82 Serial number 0000000DT971 Tag 0100

Discovery communication The DataLoader utility request the configuration

Discovery Views Logical view Historical MVS perspective: device number, LPAR, work... Physical view DASD device: capacity, space counters. Current view Current Current LPAR’s views “A DASD device (physical DASD) can be connected to many LPAR’s (MVS device)”

Info date and Last update Historical views are builted based on the Info date and Last update fields: Info date Date and time of the information. Last update Last date and time the information was checked and remained unchanged.

Reference date Current view: Represent the current DASD configuration; Just the must up-to-date information is kept; The reference date limit the view.

Logical view LPAR view: MVS perspective; Device history; Online Storage Resident Shared System PAV Private PAV base Public PAV alias Demountable Cataloged Page SMS VOLSER Device type LPAR name Type num Device number Model num SMS storage group Manufacture Unit type Plant Cylinders Serial number

Physical view Storage view: Represent a DASD device; The device information is shared by all LPAR’s; Installation capacity history; Duplicated volumes (same volser); VOLSER Manufacture Cylinders Plant Type num Serial number Model num Tag

Explorers