Direct Dump Tests Modify

Slides:



Advertisements
Similar presentations
Analog-to-Digital Converter (ADC) And
Advertisements

Digital Fundamentals Tenth Edition Floyd Chapter 12.
LSU 06/04/2007Electronics 71 Analog to Digital Converters Electronics Unit – Lecture 7 Representing a continuously varying physical quantity by a sequence.
Shuvra Das University of Detroit Mercy
Resident Physics Lectures
1 Dr. Un-ki Yang Particle Physics Group or Shuster 5.15 Amplifiers and Feedback: 3.
Analogue to Digital Conversion
29 June 2004Paul Dauncey1 ECAL Readout Tests Paul Dauncey For the CALICE-UK electronics group A. Baird, D. Bowerman, P. Dauncey, C. Fry, R. Halsall, M.
JF 12/04111 BSC Data Acquisition and Control Data Representation Computers use base 2, instead of base 10: Internally, information is represented by binary.
ARA Testbed Efficiency (Rough Cut) November 29 th Ben Rotter.
Beam Loss Analysis Tool for the CTF3 PETS Tank M. Velasco, T. Lefevre, R. Scheidegger, M. Wood, J. Hebden, G. Simpson Northwestern University, Evanston,
© 2012 Pearson Education. Upper Saddle River, NJ, All rights reserved. Electronic Devices, 9th edition Thomas L. Floyd Electronic Devices Ninth.
Ph. Farthouat CERN ELEC 2002 ADC 1 Analog to Digital Conversion  Introduction  Main characteristics –Resolution –Dynamic range –Bandwidth –Conversion.
Vegard Joa Moseng BI - BL Student meeting Reliability analysis summary for the BLEDP.
LECC 2006 Ewald Effinger AB-BI-BL The LHC beam loss monitoring system’s data acquisition card Ewald Effinger AB-BI-BL.
Frequency to Voltage Converter and Voltage to Frequency Converter Where an instrumentation system is based mainly on capturing voltage signals (analogue.
1 ECE 3336 Introduction to Circuits & Electronics Note Set #12 Frequency Response More About Filters Spring 2015, TUE&TH 5:30-7:00 pm Dr. Wanda Wosik.
Electronic Devices Ninth Edition Floyd Chapter 13.
Digital to Analogue Conversion Natural signals tend to be analogue Need to convert to digital.
Over-Sampling and Multi-Rate DSP Systems
DIGITAL VOICE NETWORKS ECE 421E Tuesday, October 02, 2012.
3.1 Figure 3.16 Two digital signals: one with two signal levels and the other with four signal levels.
Part 2 Physical Layer and Media
MIT Lincoln Laboratory XYZ 9/15/2015 APS-2 Chip: W21 R5C6 Has Quartz Support.
Data Acquisition Overview 1 Using LabVIEW to acquire, analyze and record data.
Reports from DESY Satoru Uozumi (Staying at DESY during Nov 11 – 25) Nov-21 GLDCAL Japan-Korea meeting.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
Small Signal Model PNP Transistor Section ,4.6.
PHY 202 (Blum)1 Analog-to-Digital Converter and Multi-vibrators.
PHY 202 (Blum)1 Analog-to-Digital Converter and Multi-vibrators.
University of Kansas 2004 ITTC Summer Lecture Series Network Analyzer Operation John Paden.
SL1Calo Input Signal-Handling Requirements Joint Calorimeter – L1 Trigger Workshop November 2008 Norman Gee.
MPPC Saturation Corection Idea -> how to do. MPPC Gain measurement To apply saturation correction to the beam data, all MPPC are needed to be calibrated.
1 Lab. 3 Digital Modulation  Digital modulation: CoderDAC Transmit filter Up- conversion Channel Down- conversion Receive filter ADC ProcessingDetectionDecoder.
LHC Beam Loss Monitors, B.Dehning 1/15 LHC Beam loss Monitors Loss monitor specifications Radiation tolerant Electronics Ionisation chamber development.
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
Feature Extractor Dima Chirkin, LBNL The future is here.
Filters filters. Filters A filter removes a signal’s unwanted frequency components. Figure 6.18.
Eva Barbara Holzer July 16, LHC MPP Eva Barbara Holzer for the BLM team LHC MPP CERN, July 17, 2010 Proposal on Threshold Corrections for RC Filters.
Predicting the In-System Performance of the CMS Tracker Analog Readout Optical Links Stefanos Dris CERN & Imperial College, London.
DaMon: a resonator to observe bunch charge/length and dark current. > Principle of detecting weakly charged bunches > Setup of resonator and electronics.
SRS Calibration Michael Phipps, Bob Azmoun, Craig Woody 1.
Chapter 3 TRANSMISSION IMPAIRMENT. 3-4 TRANSMISSION IMPAIRMENT Signals travel through transmission media, which are not perfect. The imperfection causes.
Electronics Technology Fundamentals Chapter 15 Frequency Response and Passive Filters.
FUNCTION GENERATOR.
 13 Readout Electronics A First Look 28-Jan-2004.
Discussion on the integrator specifications with comparison of the 3 options Debriefing meeting at LPC, 28 April 2016 François Vazeille  Summary of the.
Results of the 2007 BLM hardware tests in LSS5
Transient Waveform Recording Utilizing TARGET7 ASIC
Electronic Devices Ninth Edition Floyd Chapter 14.
2007 IEEE Nuclear Science Symposium (NSS)
An Automated calibration method from shower data
TOF CALIBRATION DATABASE
Digital Communication
Injection region BLMs – ECR
V. Suntharalingam 5 February 2008
Lock-in amplifiers
LHC BLM system: system overview
A First Look J. Pilcher 12-Mar-2004
Analog to Digital Converters Electronics Unit – Lecture 7
Chem. 133 – 2/2 Lecture.
J. Emery, B. Dehning, E. Effinger, G. Ferioli, C
Agenda 9:00-10:00 Beam Interlock System Changes Following the 2006 Audit Benjamin Todd 10:00-11:00 Beam Dump System follow-up from the 2008 Audit Jan Uythoven.
Naoki Watanabe et al. BTS 2017;2:
Beam Current Monitoring with ICT and BPM Electronics
Warm Magnet Thresholds
ENGR 1 Presentation Thomas Matthews.
Placement of the LHC BLMIs around TI8 TED (Q9)
LMS Data Correction and the Radiation Accident
CAL crosstalk issues and their implications
Presentation transcript:

Direct Dump Tests Modify Direct BLMs installed and corrected, first calibration done. Dump signals now included in Logging DB: http://issues.cern.ch/browse/CALS-112  EDMS ECR document: https://edms.cern.ch/document/1159062/1 The  Dump trigger signal have been enabled and the dump threshold lowered to 20000ADC counts.  A test have been conducted to verify the functioning of the system.  All four channels in the  electronic cards have been pulsed with a battery and dump triggers have been generated (see attached plots) when the signals exceeded the dump thresholds. xxxxx xxxx; B.Dehning

Calculation of direct dump IC monitor thresholds EBH 7.4.2011  The calculation is based on asynchronous dump on 13.3.2011 at 3:11. The thresholds are to be set at 1.5 times the losses at this dump. Uncertainties in the threshold determination are estimated to more than a factor of 5.   Result: Dump thresholds should be put to an IC (without RC filter) signal of 0.034 A. This corresponds to 0.025 Gy in 40 us. The new threshold should be in the upper part of this dynamic range: about 75-80% up from the lower end of the dynamic range. Line of calculation and arguments: BLMEI.04L6.B2I10_TCDQA.B4L6.B2 is the monitor Ruediger pointed out. It has a big RC filter (~11ms time constant) . It sits directly between the two direct dump monitors for beam 2. The integrated loss over 1.3s is 0.025Gy/s in 1.3s. Times 1.5 (the factor from Ruediger) this gives 0.05 Gy as dump threshold. The reason for taking only 0.025 even though there are two equally high peaks in the display for 1.3s integration time is, that the loss must have happened during the overlap between two integration times, and is therefore completely covered in both integrals. (This effect can be seen also at the monitor BLMQI.04L6.B2I10_MQY, which does not have a filter and is not in saturation. Therefore the losses in the two integration times can be compared in the PM display). From the monitors nearby without filter, e.g. BLMQI.04L6.B2I10_MQY, we can see that within 4 x 40us most of the charge is collected and that the dose rate (Gy/s) in the highest 40us is about a factor of 2 higher than the dose rate averaged over 4 x 40us. Therefore, the dose (Gy) in 40us is 2 x 0.05 Gy / 4 = 0.025 Gy. The dump IC monitor has also no filter: 0.05 Gy in 320us corresponds to 0.025 Gy in the highest 40us. This corresponds to 0.034 A. The assumption here is that the IC + cable + input filter of the electronics smoothes out the current peak to about an equivalent of averaging over 40 us. The input filter of the direct dump electronics is currently using a low pass filter with a cutoff frequency of 6kHz (T=26,3us) for noise reduction. Currently, the dump threshold is set to 13kGy/s. Assuming the same smoothing over 40 us, this corresponds to 0.5 Gy. This is a factor 20 higher than what we now calculated. Mariusz thinks that this is not something to worry about, as the last threshold estimate was very rough. The dynamic range of the electronics is about a factor of 65000. It is a 16bit ADC => 65536 => 96dB (theoretical value!) . Saturation effect at 1.36 uC is approximately a factor of 2 (from thesis of M.Stockner). But no correction for that is applied, because this saturation effect is also present in the monitor with the filter which we use to calculate the dose level (at approximately the same size, because the dose is nearly the same). The DD monitors are not at the same location as the reference monitor. One of the DD monitors is directly next to another IC with big filter. It can be seen that for this DD location, the signal is approximately 3 times lower than for the reference monitor. Still, my proposal is not to apply a correction, as: This factor depends on the details of the dump (it is close to 1 on a later dump this day) For the second DD monitor the factor is unknown for the asynchronous beam dump and close to 1 on a later dump that day. I’d propose to keep the thresholds on both monitors the same (not sure they can be set differently). 2010 SEM Converting factor and Threshold of the BLMDD (from Ewald): Threshold: 13kGray/s => 10uA => 5V => 32768 bits Converting factor electronic current/bits: 0.396Gray/s/bit => 305pA/bit => 152.5uV/bit Conversion Factor IC: 1 Gy = 54 uC xxxxx xxxx; B.Dehning

xxxxx xxxx; B.Dehning

xxxxx xxxx; B.Dehning

xxxxx xxxx; B.Dehning