Electrical Safety Standards

Slides:



Advertisements
Similar presentations
Regulations (Standards - 29 CFR) Flammable and Combustible liquids
Advertisements

(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
September 9, Electrical Safety Division Testing and Evaluation of Electrical Equipment Independent Laboratory Part 6 Workshop.
A PPARATUS G AS G ROUPS, T EMPERATURE C LASS AND T YPES OF E XPLOSION P ROTECTION (Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
VSD AND SS DRIVING ATEX MOTORS February Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions.
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Intrinsic Safety Testing by Gail Nicola, Electrical Engineering Technician Ed Vensko, Electrical Engineering Technician.
1 Module 3 Ignition Control. 2 Terminal Objectives Upon the successful completion of this module, participants will be able to explain the work procedures.
Site Planning and Layout  In the design phase of a facility, fire protection requirements are considered in the site layout  Water supply, traffic and.
The Association of Electrical Equipment and Medical Imaging Manufacturers ENCLOSURE TYPES Environmental Conditions : and the Appropriate:
Gas Transmission Pipelines
Electrical Power Systems
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
CURRENT ELECTRICITY The energy of moving charges (flow of electrons)
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
SITE SAFETY HAZARDS AND PROCEDURES. ELECTRICAL HAZARDS  Electricity is a serious workplace hazard.  Employees can be exposed to dangers such as : 
Chapter One Electrical Design and Component Basics.
Flammable and Combustible Liquids Presented by Martina Schmeling Adapted From OSHA.
Circuits and Electronics. Circuits A circuit is a closed path through which a continuous charge can flow. A circuit is a closed path through which a continuous.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Basic Awareness Training for all Staff
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
Unit 4: General Safety Practices
The work of CEN/TC 305 Potentially explosive atmospheres-
MICE Hydrogen Control System MICE Safety Review Meeting 4 th Oct 2011 PJ Warburton - Daresbury Lab.
29 CFR Subpart G Related Terminal Operations and Equipment.
Bi-Weekly Safety Meeting November 29, The days of using canaries in mines as primitive gas detectors are long gone..they've been replaced by fixed.
Flammable Liquids Directorate of Training and Education
Courtesy of Schools Insurance Authority. Title 8, California Code of Regulations, Section 5194 Hazard Communication determines the dangers of the chemicals.
Standards Certification Education & Training Publishing Conferences & Exhibits ISA SP12 Standards Related to Equipment in Hazardous Locations.
Rev. 1 © Chevron 2009 Hot Work Awareness Plus. Rev. 1 © Chevron Training Objectives  To explain the type of work which may constitute Hot Work.
Chapter 18 Direct Current Circuits. Electric Circuits Electric circuits control the flow of electricity and the energy associated with it. Circuits are.
Chapter 18 Direct Current Circuits. Sources of emf The source that maintains the current in a closed circuit is called a source of emf The source that.
1 ATEX classification air motors, Dagmar Dübbelde ATEX CLASSIFICATION AIR MOTORS.
Safe Handling of Flammable and Combustible Liquids.
Hazardous Area Classification 1. Hazard & Its Causes/ Types 2. Hazardous Area Definitions 3. Material Classification 4. Area Classification 5. Prevention.
NCTCOG Electrical Advisory Board
Direct Current Circuits
NONINCENDIVE INSTALLATIONS FOR CLASS I DIV 2 AREAS
Safe Handling of Flammable and Combustible Liquids
Special-Purpose Outlets— Electric Heating, Air Conditioning
Monitor Operations Procedures To Safely Control Work
THUM Adapter Impact on Hazardous Area Classification
Smitty’s Two Minute Drill #9: Special Occupancies
Electrical Junction Boxes in UAE | SPPE
Practical electricity
Personal Protective Equipment
East Carolina University Compressed Gas Safety Training Program
Basic Electricity Notes
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
CONSTRUCTION BS (BS 4533) K.F. Chan (Mr.) MEBS 6002.
Direct Current Circuits
Overcurrent Protection— Fuses and Circuit Breakers
The Safe Use of Electricity
Non-compatible chemicals
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Safe Handling of Flammable and Combustible Liquids
Hazardous Area Classification
Hundreds of people die due to explosions every year!
Parker domnick hunter. Safety of Electrical and
What is Current Electricity?
Two Minute Drill – Residential 3
D.
Gas Transmission Pipelines
Presentation transcript:

Electrical Safety Standards Chapter 44 Electrical Safety Standards National Electrical Codeâ (NECâ) • Hazardous Locations Classifications • Electrical Protections • Electrical Enclosures • Hazardous Area Wiring • Intrinsically Safe Systems

The NEC® divides hazardous locations into classes, divisions, and groups based on the chemicals handled in that area. The classification system evaluates the various types of hazardous substances and groups them according to their type and potential for hazard. Electrical classifications for hazardous locations are identified by class, division, and group. See Figure 44-1. It is the responsibility of knowledgeable personnel at each manufacturing facility to specify the appropriate hazardous zone, location, size, and classifications. Each area has specific wiring requirements.

NEMA classifies electrical enclosures according to intended use. An enclosure is a case or housing for equipment or other apparatus that provides protection for control-lers, motor drives, or other devices. See Figure 44-2. The National Electrical Manufacturers Association (NEMA) classifies enclosures according to their purpose and intended resistance to the ingress of moisture and hazardous materials. In the United States, equipment is tested to the NEMA 250 standard. Some enclosures are designed to include cooling units to remove heat generated by the enclosure contents. The most common types of enclosures are discussed below. There are other, specialized NEMA classifications that are not discussed here.

Purged enclosures are kept at a positive pressure to prevent flammable gases from entering the enclosure. A purged enclosure is a nonhazardous enclosure that is pressurized and purged with air to allow it to be used in hazardous areas. Some enclosures cannot be made explosionproof. This may be because of the required size or because of non-explosionproof instruments that must be mounted in the face of the cabinet. However, such an enclosure must be located in a hazardous area. See Figure 44-3.

Enclosure temperature codes are used to determine which devices are allowed in classified areas. A temperature code is a designation that specifies the maximum surface skin temperature obtained by an enclosure during testing by approval agencies. See Figure 44-4. Any equipment that does not exceed 185°F (65°C) is not required to be marked with the temperature code. The allowed surface temperature limit is determined by the degree of difficulty in igniting a flammable mixture and the amount of heat capacity in the enclosure that prevents a temperature rise and a resulting internal explosion.

Class I, Division 1 wiring requirements include seals to prevent flammable gases from flowing through conduit. All enclosures, even those only containing terminal strips, must be of explosionproof design. All fittings must be explosionproof. Flexible conduit can be used only if it is an explosionproof design. Conduit can become a passageway for explosive gases to move from one area to another. Therefore, seals must be used in every conduit within 18″ of any instrument or junction box, and all conduits must be sealed at the boundary between hazardous and nonhazardous areas. See Figure 44-5.

Class I, Division 2 wiring requirements are slightly less stringent than Division 1 requirements. An EYS seal must be used in every conduit within 18² of any instrument or explosionproof enclosure. All fittings between the instrument and the EYS seal are to be explosionproof. Flexible conduit, if used, can be general-purpose with provision for a continuous ground. All conduits must be sealed at the boundary between hazardous and nonhazardous areas. See Figure 44-6.

Intrinsic barriers prevent electrical hazards from entering a classified area. An intrinsic barrier is a specially designed electronic circuit containing resistors and diodes that is used to prevent any electrical ignition energy from being carried into a hazardous area along power, signal, or control wiring. Intrinsic barriers are available to protect low-level signals such as from thermocouples and RTDs and high-level systems such as 115 VAC power or signals. In addition, barriers are used to send power to transmitters and solenoids. See Figure 44-7.