Neutron Detectors for Materials Research

Slides:



Advertisements
Similar presentations
Neutron Detectors for Materials Research
Advertisements

General Characteristics of Gas Detectors
Dante Nakazawa with Prof. Juan Collar
Neutron detectors and spectrometers 1) Complicated reactions → strong dependency of efficiency on energy 2) Small efficiency → necessity of large volumes.
GM COUNTER.
Geiger-Muller detector and Ionization chamber
Radiation Detectors / Particle Detectors
Scintillators. When radiation interacts with certain types of materials, it produces flashes of light (scintillation) Materials that respond this way.
Scint. Al Internal reflection External reflection ↑ ↑ ↑ Decay Detector Development for Giant Resonance Studies By: Gus Olson Mentor: Dr. D.H.Youngblood.
Detecting Giant Monopole Resonances Peter Nguyen Advisors: Dr. Youngblood, Dr. Lui Texas A&M University Energy Loss Identifying The Particles Discovered.
Main detector types Multi Pixel Photon Counter (MPPC) and Charge Coupled Devices (CCDs) How does it work? 1. Photon hits a pixel producing electron hole.
Detecting Giant Monopole Resonances Peter Nguyen Advisors: Dr. Youngblood, Dr. Lui Texas A&M University.
Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.
Techniques for detecting X-rays and gamma-rays Pair production Creation of elementary particle and its antiparticle from a photon. Occurs only if enough.
Main detector types Scintillation Detector Spectrum.
Instruments for Radiation Detection and Measurement
10 B-based Multi-Grid Detectors as an alternative to 3 He In-beam test on the IN6 ToF spectrometer 10 B-based Multi-Grid Detectors as an alternative to.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
Type of Material: Instrumentation Review
Detectors for Slow Neutrons Tenth National School on Neutron and X-ray Scattering 24 September-11 October 2008 John M. Carpenter IPNS, SNS 26 September.
Photon detection Visible or near-visible wavelengths
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Position-sensitive detectors of thermal neutrons: types, characteristics, applications. A.V. Churakov IX International school-seminar: Actual problems.
Chapter 12 Atomic X-Ray Spectroscopy
Monday, Mar. 7, 2005PHYS 3446, Spring 2005 Jae Yu 1 PHYS 3446 – Lecture #12 Monday, Mar. 7, 2005 Dr. Jae Yu Particle Detection Ionization detectors MWPC.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Advanced semiconductor detectors of neutrons
Ionization Detectors Basic operation
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Electron pick-up. ~1/E What about fission fragments????? Bragg curve stochastic energy.
Wednesday, Oct. 18, 2006PHYS 3446, Fall 2006 Jae Yu 1 PHYS 3446 – Lecture #12 Wednesday, Oct. 18, 2006 Dr. Jae Yu 1.Particle Detection Ionization Detectors.
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY Neutron Detectors for Materials Research T.E. Mason Associate Laboratory Director Spallation.
Chapter V Radiation Detectors.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
Status report FRM2 In-Kind Contribution: a 10 B-based gas detector with macrostructured multilayers Irina Stefanescu, Yasin Abdullahi, Ilario Defendi,
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
(Chapter 7) CHEM–E5225 Electron microscopy
Fast neutron flux measurement in CJPL
Idee per lo sviluppo del Charge Identifier
Laboratory equipment Lecture (3).
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
Triple GEM detectors : measurements of stray neutron.
Gas Detectors for Neutron Dosimetry and Monitoring
Prototype production and test
PHYS 3446 – Lecture #14 Energy Deposition in Media Particle Detection
Neutral Particles.
PAN-2013: Radiation detectors
Lecture 1: Development of the Analog Gamma Camera
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Neutron Detection with MoNA LISA
Alternatives to 3He for Neutron Detection
Ionization detectors ∆
Outside the nucleus, the beta decay {image} will not occur because the neutron and electron have more total mass than the proton. This process can occur.
Background Reduction for Quantitative Gamma-ray Imaging with the Electron-Tracking Compton Camera in High Dose Areas May 26th, PS10A-10 T. Mizumoto,
Scintillation Counter
1. Introduction Secondary Heavy charged particle (fragment) production
C.Octavio Domínguez, Humberto Maury Cuna
When this happens... We see this... 12/6/2018 Steve Wotton.
NUCLEAR RADIATION DETECTORS
Radiation Sensors Radiation is emission if either particles or electromagnetic rays from a source. Particles are usually nuclear particles which can be.
ECE699 – 004 Sensor Device Technology
Radioactivity B. Sc. -III Feb Dr. Wagh G. S. M. Sc. M. Phil. Ph
X-ray detectors single photon detectors
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
Computed Tomography (C.T)
The Development of a Segmented Detector using ZnS:Ag/6Li
Presentation transcript:

Neutron Detectors for Materials Research T.E. Mason Associate Laboratory Director Spallation Neutron Source Acknowledgements: Kent Crawford & Ron Cooper

Neutron Detectors What does it mean to “detect” a neutron? Need to produce some sort of measurable quantitative (countable) electrical signal Can’t directly “detect” slow neutrons Need to use nuclear reactions to “convert” neutrons into charged particles Then we can use one of the many types of charged particle detectors Gas proportional counters and ionization chambers Scintillation detectors Semiconductor detectors

Nuclear Reactions for Neutron Detectors n + 3He  3H + 1H + 0.764 MeV n + 6Li  4He + 3H + 4.79 MeV n + 10B  7Li* + 4He7Li + 4He + 0.48 MeV  +2.3 MeV (93%)  7Li + 4He +2.8 MeV ( 7%) n + 155Gd  Gd*  -ray spectrum  conversion electron spectrum n + 157Gd  Gd*  -ray spectrum  conversion electron spectrum n + 235U  fission fragments + ~160 MeV n + 239Pu  fission fragments + ~160 MeV

Gas Detectors ~25,000 ions and electrons produced per neutron (~410-15 coulomb)

Gas Detectors – cont’d Ionization Mode Proportional Mode electrons drift to anode, producing a charge pulse Proportional Mode if voltage is high enough, electron collisions ionize gas atoms producing even more electrons gas amplification gas gains of up to a few thousand are possible

MAPS Detector Bank

Scintillation Detectors

Some Common Scintillators for Neutron Detectors   Material Density of 6Li atoms (cm-3) Scintillation efficiency Photon wavelength (nm) Photons per neutron           Li glass (Ce) 1.751022 0.45 % 395 nm ~7,000 LiI (Eu) 1.831022 2.8 % 470 ~51,000 9.2 % ~160,000 ZnS (Ag) - LiF 1.181022 450          

GEM Detector Module

Anger camera Prototype scintillator-based area-position-sensitive neutron detector Designed to allow easy expansion into a 7x7 photomultiplier array with a 15x15 cm2 active scintillator area. Resolution is expected to be ~1.5x1.5 mm2 2000-03449/arb

Semiconductor Detectors

Semiconductor Detectors cont’d ~1,500,000 holes and electrons produced per neutron (~2.410-13 coulomb) This can be detected directly without further amplification But . . . standard device semiconductors do not contain enough neutron-absorbing nuclei to give reasonable neutron detection efficiency put neutron absorber on surface of semiconductor? develop boron phosphide semiconductor devices?

Coating with Neutron Absorber Layer must be thin (a few microns) for charged particles to reach detector detection efficiency is low Most of the deposited energy doesn’t reach detector poor pulse height discrimination

Detection Efficiency Full expression: Approximate expression for low efficiency: Where: s = absorption cross-section N = number density of absorber t = thickness N = 2.71019 cm-3  atm-1 for a gas For 1-cm thick 3He at 1 atm and 1.8 Å,  = 0.13

Pulse Height Discrimination

Pulse Height Discrimination cont’d Can set discriminator levels to reject undesired events (fast neutrons, gammas, electronic noise) Pulse-height discrimination can make a large improvement in background Discrimination capabilities are an important criterion in the choice of detectors ( 3He gas detectors are very good)

Position Encoding Discrete - One electrode per position Discrete detectors Multi-wire proportional counters (MWPC) Fiber-optic encoded scintillators (e.g. GEM detectors) Weighted Network (e.g. MAPS LPSDs) Rise-time encoding Charge-division encoding Anger camera Integrating Photographic film TV CCD

Multi-Wire Proportional Counter Array of discrete detectors Remove walls to get multi-wire counter

MWPC cont’d Segment the cathode to get x-y position

Resistive Encoding of a Multi-wire Detector Instead of reading every cathode strip individually, the strips can be resistively coupled (cheaper & slower) Position of the event can be determined from the fraction of the charge reaching each end of the resistive network (charge-division encoding) Used on the GLAD and SAND linear PSDs

Resistive Encoding of a Multi-wire Detector cont’d Position of the event can also be determined from the relative time of arrival of the pulse at the two ends of the resistive network (rise-time encoding) Used on the POSY1, POSY2, SAD, and SAND PSDs There is a pressurized gas mixture around the electrodes

Anger camera detector on SCD Photomultiplier outputs are resistively encoded to give x and y coordinates Entire assembly is in a light-tight box

Micro-Strip Gas Counter Electrodes printed lithgraphically Small features – high spacial resolution, high field gradients – charge localization and fast recovery

Crossed-Fiber Scintillation Detector Design Parameters (ORNL I&C) Size: 25-cm x 25-cm Thickness: 2-mm Number of fibers: 48 for each axis Multi-anode photomultiplier tube: Phillips XP1704 Coincidence tube: Hamamastu 1924 Resolution: < 5-mm Shaping time: 300 nsec Count rate capability: ~ 1 MHz Time-of-Flight Resolution: 1 msec

Neutron Detector Screen Design The scintillator screen for this 2-D detector consists of a mixture of 6LiF and silver-activated ZnS powder in an epoxy binder. Neutrons incident on the screen react with the 6Li to produce a triton and an alpha particle. Collisions with these charged particles cause the ZnS(Ag) to scintillate at a wavelength of approximately 450 nm. The 450 nm photons are absorbed in the wavelength-shifting fibers where they converted to 520 nm photons emitted in modes that propagate out the ends of the fibers. The optimum mass ratio of 6LiF:ZnS(Ag) was determined to be 1:3. The screen is made by mixing the powders with uncured epoxy and pouring the mix into a mold. The powder then settles to the bottom of the mold before the binder cures. After curing the clear epoxy above the settled powder mix is removed by machining. A mixture containing 40 mg/cm2 of 6LiF and 120 mg/cm2 of ZnS(Ag) is used in this screen design. This mixture has a measured neutron conversion efficiency of over 90%.

16-element WAND Prototype Schematic and Results Clear Fiber 2-D tube Coincidence tube Neutron Beam Wavelength-shifting fiber Aluminum wire Scintillator Screen

Principle of Crossed-Fiber Position-Sensitive Scintillation Detector Outputs to multi-anode photomultiplier tube 1-mm Square Wavelength-shifting fibers Outputs to coincidence single-anode photomultiplier tube Scintillator screen

Neutron Scattering from Germanium Crystal Using Crossed-fiber Detector Normalized scattering from 1-cm high germanium crystal En ~ 0.056 eV Detector 50-cm from crystal

All fibers installed and connected to multi-anode photomultiplier mount