Department of Physics and Astronomy,

Slides:



Advertisements
Similar presentations
INSTITUT MAX VON LAUE - PAUL LANGEVIN Fast Real-time SANS Detectors Charge Division in Individual, 1-D Position- sensitive Gas Detectors Patrick Van Esch.
Advertisements

Jan 2009 U. Katz: Astroparticle Physics 1 What is KM3NeT – the Vision  Future cubic-kilometre sized neutrino telescope in the Mediterranean Sea  Exceeds.
Test Results on the Photomultiplier Tubes for the ANTARES Neutrino Telescope Juan-de-Dios Zornoza IFIC (CSIC–Valencia University, Spain) On behalf of the.
Calibration of the 10inch PMT for IceCube Experiment 03UM1106 Kazuhiro Fujimoto A thesis submitted in partial fulfillment of the requirements of the degree.
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
Measurement of the absolute efficiency,
Latest developments in Hamamatsu Large Format PMTs
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
1 Performance of multi-anode PMT employing an ultra bi-alkali photo-cathode and rugged dynodes Takahiro Toizumi Tokyo Institute of Technology S. Inagwa.
1 S. E. Tzamarias Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Readout Electronics DAQ & Calibration.
Catania Assembly and Design of the Optical Modules for the NEMO Phase-2 E. Leonora, S. Aiello INFN, sez. Catania.
1 Max-Planck-Institut fuer Physik, Muenchen, Germany, 2 Humboldt-Universituet Berlin, Germany, 3 Univ. Complutense, Madrid, Spain, 4 ETH, Zurich, Switzerland,
Piera Sapienza – VLVNT Workshop, 5-8 october 2003, Amsterdam Introduction and framework Simulation of atmospheric  (HEMAS and MUSIC) Response of a km.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
July 29, 2004 American Linear Collider Physics Group Victoria Linear Collider Workshop Muon Detector MAPMT Tests - Calibration R&D Scintillator Based Muon.
Improved PMTs for the Cherenkov Telescope Array project Razmik Mirzoyan for the Focal Plane Instrumentation WG Max-Planck-Institute for Physics Munich,
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
Detectors and Cross Talk Presented below are cross talk measurements carried out on 2 Burle and 1 Hamamatsu MCP PMTs and 1 Hamamatsu MultiAnode PMT (MAPMT).
MPPC update including plastic connector T2K experiment collaboration meeting 2007/4/18 (Wed) S.Gomi T.Nakaya M.Yokoyama ( Kyoto University ) T.Nakadaira.
U. Akgun, HCAL Fall Meeting, 11/11/2004, Fermilab, IL HF PMT ISSUES By Ugur Akgun The University of Iowa.
Developments in hemispherical tubes for underwater Neutrinos detection. Bruno Combettes PHOTONIS Group Product Manager PHOTONIS-Brive, France CPPM Meeting.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
LOGO The VSiPMT Project Progress in the realization of a larger prototype Felicia Barbato – University of Naples “Federico II” – Italy.
Status of the Genova activity on a direction-sensitive optical module toward the KM3 detector M.Taiuti WP3 PYLOS 16/4/2007.
Possible calibration methods for the final LXe calorimeter A. Papa 01/20/2004.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
1 MPPC update S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira (KEK) Nov KEK.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Catania Study on large area photomultipliers with superbialkali photocathode E. Leonora 1, S. Aiello 1, D. Lo Presti 2, V. Giordano 1 1 INFN, section of.
LENA Photosensor R&D Marc Tippmann Lothar Oberauer, Michael Wurm, Gyorgy Korga, Quirin Meindl, Michael Nöbauer, Thurid Mannel, Martin Zeitlmair, German.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
Cold PM test at Indiana final measurements, September 9 – 24, 2007 PM under test: Hamamatsu R7725 serial # ZK3692 (tube with Pt underlayer) Hans-Otto Meyer.
Time and amplitude calibration of the Baikal-GVD neutrino telescope Vladimir Aynutdinov, Bair Shaybonov for Baikal collaboration S Vladimir Aynutdinov,
Photo-detection EDIT EDIT 2011Single photon counting measurements with an HPD – T. GysSlide 1 Single photon counting measurements with a hybrid photon.
PMT measurements in Antares Oleg Kalekin on behalf of Antares collaboration VLVnT 2011 Erlangen
Calibration of Under Water Neutrino Telescope ANTARES Garabed HALLADJIAN October 15 th, 2008 GDR Neutrino, CPPM, Marseille.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Characterization of Hamamatsu R12199 PMTs Oleg Kalekin KM3NeT Meeting CPPM, Marseille
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
1 SuperB-PID, LNF 4/4/2011 MAPMTsSilvia DALLA TORRE COMPASS experience with HAMAMATSU MAPMTs S. Dalla Torre.
Status procurement of PMTs Oleg Kalekin KM3NeT WPF/L General Meeting Amsterdam
Development of Multi-Pixel Photon Counters (1)
The dynamic range extension system for the LHAASO-WCDA experiment
Our goal: increase the SiPM surface
PreShower Characterisations
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Characterization of the ETEL and HZC 3+ inch PMTs
PMT characterisation for the KM3NeT Project
CTA-LST meeting February 2015
IMAGE ORTHICON.
Systematic uncertainties in MonteCarlo simulations of the atmospheric muon flux in the 5-lines ANTARES detector VLVnT08 - Toulon April 2008 Annarita.
ANTARES time calibration
Instrumentation for Colliding Beam Physics 2017
Timing Counter Sept CSN I, Assisi 2004 Giorgio Cecchet.
The Pixel Hybrid Photon Detectors of the LHCb RICH
on behalf of the NEMO Collaboration
Directional Optical Module Integration
Multianode Photo Multipliers for Ring Imaging Cherenkov Detectors
Времяпролетный детектор PANDA
Recent Progress in Large Format PMTs
New developments in photodetection
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Development of hybrid photomultiplier for Hyper-Kamiokande
Photomultiplier (PMT) Tubes
Nanobeacon: A low cost calibration instrument for KM3NeT
Presentation transcript:

Department of Physics and Astronomy, International Workshop on a Very Large Volume Neutrino Telescope for the Mediterranean Sea Department of Physics and Astronomy, Catania VLVnT08 - Toulon, Var, France, 22-24 April 2008 Characterization of a prototype of a new multianodic large area photomultiplier Leonora Emanuele INFN Catania on benhalf of NEMO collaboration Toulon, April 23 emanuele.leonora@ct.infn.it

The multianodic photomultiplier Two prototypes were tested : ZF0021; ZF0025 same shape of Hamamatsu R7081 (10’’) 4 anodic ouputs 4 separate amplification chains (10 dynode stages) Each anode is sensitive to one fourth of the photocathode area  PMT is a position sensitive photo-detector Drawing taken from Hamamatsu data sheets Picture of PMT Anodes identification (front view) For testing it was used a resistive voltage divider realized according to Hamamatsu Toulon, April 23 emanuele.leonora@ct.infn.it

The Testing Facility Measurements conditions: Dark box (2 x 1.7 x 1.5) m 410 nm Laser Source pulsed: width 60 ps, frequency range 0÷40 MHz PMT for test (naked or with μ-metal cage) Monitor PMT, to check stability of the light source during measurements Light source movement system, for scanning photocathode surface Dedicated code (LabView), to control movement and data acquisition Measurements conditions: PMT with μ-metal cage -room temperature and atmospheric pressure Picture of Dark box Drawn of source movement system. θ: vertical ; φ=orizzontal semicircular guide θ φ optical fibre carriage View of the Software Picture of PMT and light source movement system Toulon, April 23 emanuele.leonora@ct.infn.it

The prototype performances: Gain Gain has been measured studying for each anode the position of the single-photon electron peak as a function of HV value. Typical charge spectrum in single pe Experimental points for sample ZF0021 Similar behaviour for anode 1, 2, 3 The anode 4 presents a smaller gain: about - 25 % @ 1500 V for ZF0021 about - 20 % @ 1500 V for ZF0025 The dependence from the High Voltage is the same for all the anodes Different behaviour for Anode 4 could be related to dynods’ geometry Toulon, April 23 emanuele.leonora@ct.infn.it

The overall response. Linearity Response of the photomultiplier when the entirely photocatode is illuminated with a plane-wave pulsed beam, measured for each anode separately Voltage supply = 1550 Volt  Gain ≈ 5E7 Linearity Anode 1 of ZF0025 Picture of the pmt positioned to illuminate the whole photocathode Every anodes presents good linearity up to 100 photoelectrons The loss of linearity over the 100 photoelectrons was already measured in the standard R7081 PMTs Toulon, April 23 emanuele.leonora@ct.infn.it

The overall response. Charge and Timing Single photon charge spectrum Transit Time distribution in spe Discriminator threshold = 20 mV  1/ 3 spe Anode2 Anode A1 A2 A3 A4 P/V ratio 3.03 3.09 2.95 2.75 Gain [x 107] at 1550 V 5.0 5.4 3.9 σE / E % 33.62 30.62 37.34 35.15 TTS [ns] (FWHM) 4.62 3.95 3.54 4.16 Dark count rate (1/3 spe) ≈ 1Khz for each anode Summary of the ZF0025 properties Performances are comparable, except for gain of anode 4 Toulon, April 23 emanuele.leonora@ct.infn.it

Definition of Secondary Pulses According to Hamamatsu Toulon, April 23 emanuele.leonora@ct.infn.it

The overall response. Spurious pulses Typical Afterpulse 1 distribution Typical Afterpulse 2 distribution Pre pulses Delayed pulses Single pe typical Timing Distribution Anode A1 A2 A3 A4 Pre pulse [%] 0.05 0.18 0.24 Delayed pulse [%] 7.74 7.96 7.14 6.50 After Pulse 1 [%] 1.57 1.91 1.68 1.22 After Pulse 2 [%] 10.87 12.53 13.49 10.41 Summary of spurious pulses for ZF0025 Values are comparable ! Toulon, April 23 emanuele.leonora@ct.infn.it

The local response Response of each anode during the scan of the photocatode surface, with a single photoelectron pulsed beam ( spot’s diameter = 5 mm ) Used MAP: 324 local measurements with equal angular step Picture of the light source movement system to scan the photocathode Toulon, April 23 emanuele.leonora@ct.infn.it

The local response measured Area of the single photon peak for each anode. Are included events with charge more to 1/3 pe A1 A2 A4 A3 Reference system adopted Identification of the emission point from photocathode Each anode corresponds to one fourth The photocathode local response to single photoelectron for ZF0025. Color scale: in red the largest value; in blue the value less than 2 % of the largest Toulon, April 23 emanuele.leonora@ct.infn.it

The cross talk Measures of the 4 anodic signals when the center of sector 1 was illuminated with a spot Illuminated point 5 mm diam. laser intensity= 15 pe At any intensity light, in coincidence with main unipolar signal from A1, capacitive coupling between dynod chains generates bipolar parasitic signal in anodes A2, A3, A4 Parasitic signal amplitude 16 % of the main Parasitic signal charge 3% of the main Similar results were obtained illuminating the center of sectors A2, A3, A4 Pulse shape analysis in dedicated electronic board could improve the identification of the main signal Toulon, April 23 emanuele.leonora@ct.infn.it

Conclusions Two prototypes of the 4 anodes large area PMT were tested for each anode separately. The measurements present: good linearity up to 100 pe gain around 5E7 at voltage of 1550 volt similar time and charge characteristics at different anodes; only one anode (A4) presents smaller gain ( - 20 % @ 1500 V ) good identification of the emission points from photocathode presence of cross-talk: bipolar parasitic pulses with amplitudes about 16% of the main signal and a negligible charge, around 3% of the main Toulon, April 23 emanuele.leonora@ct.infn.it

… end. Thank you Toulon, April 23 emanuele.leonora@ct.infn.it

additional slides Toulon, April 23 emanuele.leonora@ct.infn.it

Typical spe pulse shape distribution Toulon, April 23 emanuele.leonora@ct.infn.it

Light Source Calibration Using a Hybrid Photo Diode (HPD) for the single-photoelectrons conditions light spectra for different laser power Using a bolometer for the range from 10 to 100 photoelectrons Toulon, April 23 emanuele.leonora@ct.infn.it

Amplitude of Cross – Talk signals is around 16 % respect to the main Amplitude of cross-talk signals (15 pe) C1 = anode1 ( trigger) ; C2 = anode2 ; C3 = anode3 ; C4 = anode 4 A1 A2 A3 A4 Amplitude of Cross – Talk signals is around 16 % respect to the main Toulon, April 23 emanuele.leonora@ct.infn.it

Negligible charge. Less than 3 % respect to main Charge of cross-talk signals (15 pe) C1 = anode1 ( trigger) ; C2 = anode2 ; C3 = anode3 ; C4 = anode 4 A1 A2 A3 A4 Negligible charge. Less than 3 % respect to main Toulon, April 23 emanuele.leonora@ct.infn.it

LabView code to control scanning Toulon, April 23 emanuele.leonora@ct.infn.it