NEW PART B Design Impacts Peter Chilvers - May 2007.

Slides:



Advertisements
Similar presentations
BS 9999 – The LFB Experience Fire Engineering Group
Advertisements

Fire-fighting & Rescue in Buildings with Engineered Solutions Roy Wilsher Director Community Protection & Chief Fire Officer.
NFPA-101, LIFE SAFETY CODE, 2003 EDITION Chapter 15 Existing Schools
Loft Conversions - The building regulations Chris Wigley MD London Building Control Ltd
THE HIGHLAND COUNCIL BUILDING STANDARDS SERVICE
7 | Means of Egress (Life Safety Code)
Typical Plumbing System
Regulatory Reform (Fire Safety) Order 2005 Fire Safety Order What is the Fire Safety Order? The order was made, under the Regulatory Reform Act 2001.
Fire-Resistive Construction (2nd part)
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Summary of NFPA 101 Interior Finish Requirements
Welcome to Energy efficiency for gas-fired and oil-fired domestic heating and hot water systems Session A: Course introduction.
Staying Safe: Disability, Fire and the Law Colin Todd, Managing Director C. S. Todd & Associates Ltd C.S. TODD & ASSOCIATES LTD C S T A.
Guidelines and Required Codes That Affect Building Design
Fire Precautionary Arrangements Presented by Mick Leadbetter Fire Safety Adviser.
1 Lincolnshire Fire & Rescue Training Centre FIXED INSTALLATIONS DRY AND WET RISERS COMPETENCE STATEMENT 373.
Air & Smoke Movement in and around High Rise buildings (Air Tracks) Mark Fishlock 2011.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
Smoke shafts vs pressurisation
Part B – Fire Safety Technical Seminar by Sussex Building Control West Sussex Fire & Rescue Service.
Hotels and Guest Houses the way forward. New ways of thinking for changing times.
High-Rise Hotels New Codes General Fire Safety Information Ted Erb Fire Prevention Officer Bellevue Fire Department April
IBC 2006 Chapter 5 Building Height and Areas After determining occupancies, the code analysis determines what height and areas are allowable for the occupancy.
Pre-qualification Structural Learning – Brief Introduction to MOE, FRC & MOA 29 March 2003 Aims  Recall your memory : how to review your scheme according.
Buildings and Structures 2 Natural and Mechanical Ventilation.
UNIT III BUILDING TYPES Syllabus: Residential, institutional, commercial and Industrial – Application of anthropometry and space standards-Inter relationships.
“People feel better in Colt conditions” | “People feel better in Colt conditions” | Colt International Ltd Smoke curtains.
Colt International Ltd
Copyright © International Fire Consultants Ltd Sprinklers – An essential tool in fire engineering design Jon Pagan MA(Cantab) CEng MIFireE Director of.
“People feel better in Colt conditions” | “People feel better in Colt conditions” | Colt International Ltd Smoke and.
Registration no: Fire Engineering Design Consultants – treating your fire safety concerns Designing residential fire safety & the challenging area.
Building Codes and Interior Design
Atrium Fire Protection
Means of Egress Chapter 4.
Improving smoke control and protecting lives Air Sealing Industrial, Commercial, Institutional and Multi-Family Buildings to Improve Smoke Control.
Building Codes Intended to protect the public by establishing minimum standards of building safety.
Prof. Kyriakos Papaioannou ARISTOTLE UNIVERSITY GREECE 7th Intern. Sprinkler Conference-Copenhagen 24-25/6/
Neil Cooper Fire Safety Residential Implementing the Changes.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
“People feel better in Colt conditions” | feel better in Colt conditions” | Colt International Ltd Smoke control.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Sprinkler Loads on Trusses
Managing Fire Safety In Common Parts of Flats and Mixed Use Buildings Simon Gibbins Merseyside Fire and Rescue Service.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
FIRE SAFETY IN MULTI-RESIDENTIAL HOUSING (Assisted Living & Extra Care) Presented by Roger Standish & Andrew Crooks.
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
Using existing lifts in existing buildings to evacuate disabled persons Derek Smith Technical Director UK Lift and Escalator Industry Association.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
INFORMATION ABOUT: EUROPEAN FIRE CLASSIFICATION..
CITY OF HARARE EMERGENCY SERVICES
BOMBA BRIEFING QUESTIONAIRE FOR 30 AUGUST 2017
Code of Practice for Fire Safety in New and Existing Community Dwelling Houses Eamon O’ Boyle.
SAFETY | TRAINING | CONSULTANCY| STAFFING SOLUTIONS
FIRE SAFETY IN HOTEL (BIS )
Safety and Prevention of Typical Fire Plan
Colt International Ltd
AR-315 BUILDING CODES & BYE LAWS
Wilson Hall Fire Protection Features
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Decree of the Ministry of Interior 3rd August 2015 The “so called” Italian Fire Prevention Code - IFC: S6 – Fire Control and Suppression provisions.
Total Fitness Gym By Student Architect Jhonatan Rubio
Design of Evacuation System for High-Rise Building Danqing Yu
INFORMATION ABOUT: EUROPEAN FIRE CLASSIFICATION.
February 2019.
Interactive Source: Fire Statistics Great Britain,
Smokes extraction principle
Building standards Mr. Da Silva.
RiverView Condominiums II Chicago, IL
Presentation transcript:

NEW PART B Design Impacts Peter Chilvers - May 2007

Architectural Practice INTRODUCTION Peter Chilvers FRICS MBEng PRP ARCHITECTS 020 8339 3093 Surrey ~ Smithfield Milton Keynes ~ Manchester Winners Architectural Practice of the Year 2007 PRP recently declared as “The world’s largest residential design practice”

AIMS OF PRESENTATION PREVENT To look at the new factors that stand to influence the design of houses and apartments Note any issues or trends Discuss possible design solutions PREVENT

NEW ADB ~ CORE DESIGN IMPACTS sprinklers Smoke Control Fire Fighting Means of Escape layouts Management issues Inclusive access considerations Relationship with Fire Engineering

ADB 2006 ~ HOW DO WE FIND IT ? OR

HOUSES

HOUSES ~ DIAGRAM 1 ADB1 Dwellinghouse with upper floors below 4.5m Single storey dwellinghouse Escape via stair and egress windows. (Alternatively provide a protected stair) Escape via entrance hall. Inner Rooms provided with egress windows/doors. 4.5m Escape via entrance hall. Inner Rooms provided with egress windows/doors. Dwellinghouse with more than one floor above 4.5m Escape via protected stair. Alternative escape route, or sprinkler coverage.No Inner Rooms. Dwellinghouse with one floor above 4.5m Escape via protected stair. No Inner Rooms allowed. Escape via protected stair. No Inner Rooms. 7.5m Escape via protected stair. Inner Rooms provided with egress windows Escape via protected stair. Inner Rooms provided with egress windows. 4.5m Escape via entrance hall. Inner Rooms provided with egress windows. Escape via entrance hall. Inner Rooms provided with egress windows.

TALLER HOUSES ~ 4 STOREYS AND MORE Protected Stair + AFD + fire separation over 7.5m + ALTERNATIVE ESCAPE OR Protected Stair + AFD SPRINKLER COVERAGE (THROUGHOUT)

OPEN SPATIAL PLANNING IN HOUSES Allowed in two storey housing Not permitted for higher housing, even with sprinkler protection and the fact that enclosure now allows non closing FD ! Recent approval for open plan GF in three storey housing on the following basis: Escape via stairs and GF if tenable FR cut off screen to stairs @ FFL with held open FD Bedroom Bedroom Sprinkler coverage First Floor Escape via egress windows @FFL (if GF untenable) Ground Floor (open plan Kitchen, Lounge / Diner)

“SENSITIVE” HOUSES Smoke Exhaust Can provide: ~ Early warning Can we create a fire safe sensitive house ? Sprinklers (fast response) AFD Smoke Control (Passive or Systems) ? Can provide: ~ Early warning ~ Fire suppression ~ Tenable escape routes ~ Time to escape or “safely stay in place” = Flexibility of Layout

within 45m of all points within the dwellinghouse FIRE FIGHTING ~ HOUSES Access to: within 45m of all points within the dwellinghouse + all access standards 20m max reversing limit open for discussion (Diagram 24 ADB1)

APARTMENTS

APARTMENT LAYOUTS Standard existing flat layouts (as previous ADB) Max 9m travel distance if open plan, or 9m max within protected entrance hall MULTI STOREY APARTMENTS either provide protected stairway, AFD, and alternative exits from levels above or below entrance level (as per existing ADB) OR protected stairway + L2 AFD (all rooms and circulation areas) (subject to any floor level being max 7.5m ± entrance level) protected stairway + AFD (circulation areas, etc) + sprinkler coverage throughout (no height limitation)

OPEN PLAN / SPATIAL APARTMENTS ADB does not recognise (over 9m travel distance) Many duplexes seek open spatial upper level Any solutions? Arup Fire - have Type Approval based on strategic AFD and layout Use of sprinklers, AFD, smoke control and layout being developed Seems to be OK Stateside !

MEANS OF ESCAPE FROM FLATS # 1 ADB2 principles and travel distances remain the same TRAVEL DISTANCE: Single direction = 7.5m max Alternative routes = 30m max (Flat door to entry to Protected Stair or Stair Lobby) SMALL BUILDING CATEGORY: Basics the same, i.e. – max 11m Fl above GL – only 3 storeys above Ground Storey BUT now allows ancillary accommodation at any level if lobby approach BUT prohibits stair connecting to any covered car park (these buildings are allowed modified standards)

MEANS OF ESCAPE FROM FLATS # 2 AOV 7.5m max Vented Corridor or Lobby 4.5m max in unvented Small Buildings OR

MEANS OF ESCAPE FROM FLATS # 3 Protected stairway 7.5m max Unvented corridors STAIR LOBBY Sterile Vented No accommodation to enter directly Unlimited size Options of sizing and layout Central lobby zone – one vent (AOV or shaft) = SPACE GAINS

NATURAL SMOKE VENTING OF COMMON AREAS Venting required to zone (corridor, lobby, stair lobby) immediately proceeding entry to protected stair AOV to single stair OV to multi stair (including any dead end leg) OV to protected stair (AOV where single stair) AOV and OV (to corridors etc) 1.5m² OV (stairs) 1.0m² Or BS12101 test data for Equivalent area air flow

NATURAL VENTING ~ SMOKE SHAFTS ADB2 (Section 2.26) now contains detailed criteria for smoke shafts: Outline = vertical max 4m length offset (@ max 30°) closed base 1.5m² area (min 0.85m l) head 2.5m above top ceiling level discharge @ least 0.5m above roof FR construction and E30S vents AFD activation on fire floor and head 2.5m Smoke Vents @ high level 1.5m²

SMOKE CONTROL VIA MECHANICAL VENTILATION ADB2 Section 2.27 allows for mechanical ventilation to BS EN 12101-6:2005 (which covers ± pressure systems) Travel Distance guidance remains the same This approach is very effective, but does not seem to be overly popular with designers or clients

EXTENDED CORRIDOR SYSTEM # 1 Means of Escape Phase Powered Inlet Air 15 – 20m in any one zone Powered Smoke Exhaust Smoke exhaust ensures reasonably tenable conditions to escape route (much better than ADB base standards) AFD activated – typically 2m³/s exhaust rate – shafts approx. 0.6m² area - system needs maintenance (regular) – sensor selected and reversible fan operation

EXTENDED CORRIDOR SYSTEM # 2 Fire Fighting Phase Powered Smoke Exhaust Powered Smoke Exhaust Fans purge smoke from corridor and staircase (Fire Brigade switch both fans to extract and leave stair doors open) Natural Air Inlet

No travel distance limitations BALCONY APPROACH # 1 BS5588-1: 1990 Worth a revisit – How open? Traditionally single aspect How close can blocks be without creating smoke logging? Can there be some enclosure and still provide equivalent smoke/fire venting ? No travel distance limitations but 60m for fire fighting

BALCONY APPROACH # 2 Open Balconies Enclosed Balconies ? Smoke Curtains / Downstands AO Louvres equiv. H x L H x L Enclosed Balconies ?

SPRINKLERS IN TALLER APARTMENT BLOCKS Apartment blocks with any floor more than 30m above GL must have sprinkler coverage to all dwelling accommodation areas at all levels ADB2, Section 8.14 Installations can be to BS9251:2005 (despite integral 20m ht limit) Also watch for high fire load and 180m² room size limitations Riser duct sizes Space for tanks/pumps Ceiling service zone depths

COMPENSATORY ALLOWANCES NOT FULLY RECOGNISED BY ADB SPRINKLERS COMPENSATORY ALLOWANCES NOT FULLY RECOGNISED BY ADB Increased travel distances – alternative ventilation – openings to atria – decreased fire ratings – open spatial duplexes ! ! ! LEFT TO FIRE ENGINEERING SOLUTIONS

and project specifically VERY TALL BLOCKS Design Holistically and project specifically Issues: “Defend in Place” – Safe to Stay – realistic emergency procedures Evacuation  Fire Fighting – Single Staircases – Lift redundancy Identify and consider all risks (including extreme)

FIRE FIGHTING ~ APARTMENTS Fire Brigade access to within 45m of all points within each dwelling

45m RULE ~ APARTMENTS 45m from fire appliance to all points of all flats ( +10% tolerance ?) Consider fire fighting technique – hose runs from fire appliance into building – along corridors – up stair flights – along landings – along corridors/lobbies on fire floor – into flat Say min 13m within flat Say min 7.5m travel distance + landings = 22m Depending upon storey height and pitch = 5-6m per storey + landing lengths Depending on fire park position outside building ALWAYS needs measuring but highly likely that 3+ stories will now need FIRE MAINS !

(and visible position) FIRE MAINS To be on face of building Fire access to within 18m (and visible position) Wet risers if over 50m height

FIRE FIGHTING SHAFTS ~ APARTMENTS Greater clarity of Fire Fighting Shaft provisions for Apartments ( required if >18m above approach level) Wet Risers if over 50m (was 60m) If sprinklered all accommodation to be within 60m of riser outlet If not sprinklered then 45m max hose run from riser in ordinary protected stairway but 60m if from riser in a FFS 120 mins FR FR as required for building (max 60 mins for flat compartment walls ADB2 Table A1) Flat entrance doors FD30S + all other relevant requirements of BS5588-5:2004

FIRE FIGHTING ~ HYDRANTS New Requirement: applies to new building with a compartment > 280m² Sited > 100m from an existing fire hydrant See ADB2, Section 15.7/8 If building fitted with fire mains Hydrant within 90m of inlet No fire mains Then hydrant within 90m of entrance, and @ 90m centres If no water mains then SWS supply

DISABLED PEOPLE IN FLATS “Inclusive escape “ required in an overall sense by ADB1 and 2 ADB guidance does not require provisions for ordinary apartments ( Because of : - compartmentation – “defend in place” – simultaneous evacuation possible, but not often needed – no history of problems) Specific designs including Wheelchair Disabled Units might generate a need for consideration of Refuge provision (in staircore or lobby) Refuge numbers do not necessarily need to equal disabled population Consider Risk Assessment and management needs Lifetime Homes?

FIRE SAFETY MANAGEMENT ADB – Volume 2 – Section 0.13: “Building Regulations do not impose any requirements on the management of a building. However, in developing an appropriate fire safety design for a building it may be necessary to consider the way in which it will be managed. A design which relies on an unrealistic or unsustainable management regime cannot be considered to have met the requirements of the Regulations. Once the building is in use the management regime should be maintained and any variation in that regime should be the subject of a suitable risk assessment. Failure to take proper management responsibility may result in the prosecution of an employer, building owner or occupier under legislation such as the Regulatory Reform (Fire Safety) Order 2005.” Consultation and Compatibility required across DESIGN  MANAGEMENT  FIRE AND EVACUATION PLANS

Thank You CONCLUSIONS Centred around traditional layouts Better Guidance Easier to use for standard layouts But not ground breaking Centred around traditional layouts Poised to be overtaken by Fire Engineering ? Thank You