ISO-13485:2003 by: Aaron Lupo.

Slides:



Advertisements
Similar presentations
ISO 9001:2000 Documentation Requirements
Advertisements

Transition from Q1- 8th to Q1- 9th edition
Exercise 1 TDT 4235 Tor Stålhane IDI / NTNU. Intro The strength of ISO9001 and many other standards is that they focus on “What shall be done” and leave.
DOCUMENTATION REQUIREMENTS Based on ISO 9001:2008
Welcome to ISO 9000 for Managers
Understanding the Requirements Qimpro Standards Organization
ISO 9001 : 2000.
EPSON STAMPING ISO REV 1 2/10/2000.
SAE AS9100 Quality Systems - Aerospace Model for Quality Assurance
1 Quality Management Standards. 2 THE ISO 9000 FAMILY ISO 9000: 2005 Identifies the fundamentals and vocabulary for Quality Management Systems (QMS) ISO.
The ISO 9002 Quality Assurance Management System
Quality Management System
ISO 9001 Interpretation : Exclusions
Prepared by Long Island Quality Associates, Inc. ISO 9001:2000 Documentation Requirements Based on ISO/TC 176/SC 2 March 2001.
Implementing a Quality Management System
ISO 9001:2000 Intro Presented By: Brad D. Agenda Overview of QMS Fundamentals ISO 9001:2000 Overview & Requirements.
ISO 9000 Certification ISO 9001 and ISO
5.2 Personnel Use competent staff Supervise as necessary
4. Quality Management System (QMS)
4. Quality Management System (QMS)
Allison Kotchman Victoria Gilbride Raechel Huebner.
Welcome ISO9001:2000 Foundation Workshop.
JENN SHAFNER BRIAN KROUSE CLINT KEHRES. Pre ISO 9000  The BS 5750 standard required factories to document manufacturing procedures.  BS 5750 was known.
Medicare Certification Systems Thilak Wickremasinghe, Director/CEO Sri Lanka Accreditation Board.
QUALITY MANAGEMENT SYSTEM ACCORDING TO ISO
Annex 1 – Changes in the detail
13th &14th July 2010 Gaelle Rousseau-Lamour
Quality Management System
WHAT IS ISO 9000.
Quality Management Systems P.Suriya Prakash Final Mech Vcet
ISO STANDARDS TRAINING & CONSULTING
ISO 9000 and Public Awareness and Information Session 22 February 2006 Owen Glave, MBA-TQM.
ISO 9001:2000 QUALITY MANAGEMENT SYSTEM REQUIREMENTS
Software Quality Assurance Lecture 4. Lecture Outline ISO ISO 9000 Series of Standards ISO 9001: 2000 Overview ISO 9001: 2008 ISO 9003: 2004 Overview.
Introduction to ISO 9001:2000.
ISO 9000 & TOTAL QUALITY ISO 9000 refers to a group of quality assurance standards established by the International Organization for Standardization.This.
Visit us at E mail: Tele:
ISO 9001:2008 to ISO 9001:2015 Summary of Changes
AET0012PPT by Dr. Anwar El-Tawil Dr. Anwar El-Tawil Director ISO Programme for Developing Countries QUALITY MANAGEMENT SYSTEM ACCORDING TO.
ISO 9001:2000 The 5 Phase Plan to Implementation Sterling, VA Terry & Associates Quality.
ANWAAR SPENCE BRAD BAGLIA NATHAN COOK TIMOTHY CARTER.
It was found in 1946 in Geneva, Switzerland. its main purpose is to promote the development of international standards to facilitate the exchange of goods.
The common structure and ISO 9001:2015 additions
The Second Annual Medical Device Regulatory, Reimbursement and Compliance Congress Presented by J. Glenn George Thursday, March 29, 2007 Day II – Track.
QUALITY MANAGEMENT SYSTEM
ISO 9001:2015 Subject: Quality Management System Clause 8 - Operation
WORKSHOP ON ACCREDITATION OF BODIES CERTIFYING MEDICAL DEVICES INT MARKET TOPIC 9 CH 8 ISO MEASUREMENT, ANALYSIS AND IMPROVEMENT INTERNAL AUDITS.
Workshop on Accreditation of Bodies Certifying Medical Devices Kiev, November 2014.
10 June 2016 | Proprietary and confidential information. © Mphasis 2013 Overview of ISO 9001:2008 Mar Internal Auditor Training.
WORKSHOP ON ACCREDITATION OF BODIES CERTIFYING MEDICAL DEVICES INT MARKET TOPIC 6 CH 5 ISO MANAGEMENT RESPONSIBILITY Philippe Bauwin Medical.
External Provider Control
UNDERSTANDING ISO 9001:2008.
Quality Management Systems: Elements, implementation of documentation
External Validation of Quality Programs
Prepared by Rand E Winters, Jr. ASR Senior Auditor October 2014
UNIT V QUALITY SYSTEMS.
Quality Management Systems – Requirements
HIGHLIGHTING THE KEY CHANGES
Transition ISO 9001:2008 to ISO 9001:2015
QUALITY MATTERS - OVERVIEW OF ISO QUALITY MANAGEMENT SYSTEM
ISO 9000 Dr. S. Thomas Foster, Jr..
Medical Device Design and Development
ISO-13485: by: Aaron Lupo.
ISO 9001:2008 Quality Management Systems
TS Training Presented by: Internal Auditor Training.
ISO-13485: by: Aaron Lupo.
ISO-9001:2000 Quality Management Systems
External Validation of Quality Programs
ISO-13485: by: Aaron Lupo.
Presentation transcript:

ISO-13485:2003 by: Aaron Lupo

Objectives Overview of ISO 13485:2003 Background / History of the new standard Structure Permissible exclusions from the standards Regulatory/Industry/International acceptance

Why did they have to change it? Current ISO 13485:96 standard is based on ISO 9001:94. As of December 15, 2003 ISO 9001:94 will be obsolete Not recognized by oversight bodies ISO 13485:96 would be modeled after an antiquated approach. It was time. ISO standards are reviewed every 5 years

Why not adopt ISO 9001:2000 ? The Medical Device Industry did not agree with all the changes to ISO 9001:2000 Harmonizing with the QSR (GMP) requirements ISO 9001:2000 places an emphasis on Continual Improvement and Customer Satisfaction Harmonizing EN 4600X Standards with ISO 1348X Not user friendly Lacked Process orientation Could not tailor ISO to scope of registration (service)

What they wanted to accomplish in the new revision Useable by organizations of all sizes Specific to the Medical Device Community Easily Understood Compatible with “other” management systems 9001:2000, ISO 14001 Direct relationship with the activities involved in running the business

ISO 13485 Series Standards - QMS ISO 9000: Quality management system fundamentals and vocabulary Except as noted in section 3 of 13485 ISO 13485: Quality Management System Requirements combines ISO 13485 and 13488 limitations will be indicated on certificate ISO/TS 14969: Quality Management Systems-Medical Devices-Guidance on the Application of ISO 13485

What has Changed? · ISO 13485 now has a totally new structure, ‘20 elements’ is too linear, Adopted ‘process’ approach Emphasis is now on regulatory requirements for a quality management system rather than a quality assurance system. Increased attention to production of a conforming product and delivery of a conforming service is included in and is part of the quality management system. There is now only one management system requirement standard, i.e. ISO 13485, where previously there were two requirement standards: ISO 13485 and ISO 13488.

2003 Changes Continued Went from 20 elements to 8 Elements 4-8 contain all the requirements Emphasis on Consistency through Documentation Does Allow for permissible exclusions Exclusions need justification! Organization replaces supplier to refer to the company implementing the standard Supplier replaces subcontractor when referring to companies that your company purchases goods and services from

2003 Changes - Continued Top Management must be involved in establishing and communicating the purpose and direction of the organization The management system begins and ends with objectives established by Top management Top management – responsibility for profit or loss* Top Management needs to create an atmosphere in which people are not afraid to become involved, and desire to help the company meet its goals and objectives

Why Can’t the FDA change Part 820 to harmonize it with 9000:2000 The FDA and medical device regulators take issue with following ISO 9001:2000 philosophies: Customer Satisfaction- goes above and beyond the safety and efficacy of medical devices. Evaluating customer satisfaction beyond safety is not FDA’s purpose Continuous Improvement- done simply for the sake of operating more efficiently is outside the scope of medical device regulatory agencies. Documentation- documentation is needed to know what a company intends to do and what they actually did- ISO 9001:2000 requires less documentation than does 13485:2003 Process Approach- FDA does not feel its necessary for companies to change the structure of their documentation. FDA is assuming the purpose of the change in ISO is a change in documentation and that companies do not already use the process approach.

FDA/QSR harmonization with the ISO Standards The FDA is planning on some level of harmonization with ISO 13485 in late 2002 – early 2003. Provided that ISO 13485 will remain more true to the medical device/regulatory viewpoint Many other countries rely on ISO standards in regulating medical devices. Promotes International Consistency. FDA and device regulatory agencies from other countries can more readily rely on one another's inspections and exchange inspection reports if the quality system requirements are similar. Very important for establishing MRAs and MOUs between countries.

Why Would Medical Device Manufacturers want to maintain ISO 9001:2000 Certification as well as 13485:200X Customers (Doctor’s, Hospitals, OEM’s) perceive a level of security in knowing they are buying from a manufacturer that has an ISO 9001 certified system. Helps companies obtain product certification CE mark, Companies do not have to be ISO certified to get CE Mark Depending on the product or service companies could opt for ISO 17025

Permissible Exclusions - Allowable (7.5.3) Identification and traceability - only partially applicable where there is no specific traceability requirement for the organization’s product (7.5.2) Customer property - Nothing is provided from the customer to the supplier in the realization of its products or processes (7.6) The organizations needs no measuring and test equipment to provide evidence of conformity

Differences:

Guidance: ISO 14969:200X will be the guidance document for implementation to 13485:2003 Section 3 of ISO 13485 has additional Terms and Definitions not included in ISO 9000:2000 ISO 9000:2000 and ISO 9004:2000 used as “consistent pair” IAF Guidance documents www.iaf.nu

Differences: Section 4.1 13485: "Maintain the Effectiveness of these processes" Records that you are meeting requirements and stated objectives 9001:2000: “Continual Improvement of these Processes“

Differences: Section 4.2.3 Organization must define the period for retention of obsolete documents Duration must be for the life of the device or as specified by relevant regulatory requirements (GMP/GLP) 9001:2000 Does not specify retention times

Differences: Section 4.2.4 Additional Requirement in Section 4.2.4 13485:2003 that are not in 9001:2000 "Records shall be established and maintained to provide evidence of conformity to requirements and of the effective operation of the quality management system. records shall remain legible, readily identifiable and retrievable. A documented procedure shall be established to define the controls needed for the identification, storage, protection, retrieval, retention time and disposition of records. Records from suppliers which demonstrate conformance to specified requirements and the effective operation of the quality management system shall be maintained. The organization shall retain the records for a period of time at least equivalent to the lifetime of the medical device as defined by the organization, but not less than 2 years from the date of last shipment from the organization. NOTE National or regional regulations may require a period longer than 2 years. The organization shall establish and maintain a record for each batch of medical devices that provides traceability to the extent specified in 7.5.3 and identifies the quantity manufactured and quantity approved for distribution. The batch record shall be verified and approved. NOTE A batch may be a single medical device."

Differences: Section 5 Section 5.1 of 13485:2003 does not require "Continually Improving its effectiveness" ISO 9001:2000 does. Section 5.2 of 13485:2003 focus is on meeting the customers needs 9001:2000 is focused on meeting and exceeding the customers needs. Section 5.3 of 13485:2003 emphasizes maintaining the system 9001:2000 talks about continual improvement

Differences: Section 5 Section 6.2.2 of 13485:2003 Requires a procedure for training where as ISO 9001:2000 does not. Section 6.4 Work Environment of 13485:2003 is more detailed (i.e. health records, cleanliness of clothing and personnel, environmental monitoring) than the same section in 9001:2000

Differences: Section 7 Section 7.3 Design and Development of 13485:2003 references ISO 14971 (Risk Analysis) 9001:2000 does not. Section 7.5.1 of 13485:2003 has added sub-clause G, which talks about packaging and labeling. Section 7.5.1.1 Cleanliness of Product and contamination control (Cleaning of product) is added for 13485:2003 Section 7.5.1.2 Installation (Installing the Device) is added for 13485:2003 Section 7.5.1.3 Servicing (After the Device is installed) is added for 13485:2003

Differences: Section 7 - cont’d Section 7.5.2 Validation of processes for production and service provision- additional requirements for 13485: “The organization shall establish and maintain documented procedures for the validation of the application of computer software (and changes to such software and/or its application) for production and service operations and measuring and monitoring operations (see 8.2) that affect the ability of the product to conform to specified requirements. Such software applications shall be validated prior to initial use. The results of validation shall be recorded (see 4.2.4).” Particular requirement for sterile medical devices: “The organization shall subject the medical device to a validated sterilization process and record all the process parameters of the sterilization process (see 4.2.4).”

Differences: Section 7 - cont’d Section 7.5.3 Identification and Traceability- additional requirements for 13485: Particular requirements for active implantable medical devices and implantable medical devices: a) “When defining the extent of traceability, the organization shall include all components and materials used, and records of the environmental conditions when these could cause the medical device not to satisfy its specified requirements.” b) “The organization shall require that its agents or distributors maintain records of the distribution of medical devices with regard to traceability and that such records are available for inspection.” c) “The organization shall ensure that the name and address of the shipping package consignee is recorded (see 4.2.4).”

Differences: Section 7 - cont’d Section 7.5.5 Preservation of product- additional requirements for 13485:  ”The organization shall establish and maintain documented procedures for the control of product with a limited shelf-life or requiring special storage conditions. Such special storage conditions shall be controlled and recorded.” (FIFO)

Differences: Section 8 Section 8.1 Measurement, analysis and Improvement- additional Requirements for 13485: If statistical techniques are used, organization shall establish and maintain documented procedures to implement and control their application.

Differences: Section 8 - cont’d Section 8.2.1 Customer Feedback- Additional Requirements for 13485: “The organization shall establish and maintain a documented feedback system to provide early warning of quality problems and for input into the corrective and preventive action system [see 7.2.3c)].” “If regulations require the organization to gain experience from the post-production phase, the review of this experience shall form part of the feedback system (see 8.5.1).”

Differences: Section 8 - cont’d Section 8.2.4 Monitoring and measurement of Product- additional requirements for 13485: Particular requirement for active implantable devices and implantable devices: “The organization shall record (see 4.2.4) the identity of personnel performing any inspection or testing.” Section 8.3 Control of nonconforming product- additional requirements for 13485: “If product needs to be reworked (one or more times), the organization shall document the rework in a work instruction that has undergone the same authorization and approval procedure as the original work instruction. Prior to authorization and approval, a determination of any adverse effect of the rework upon product shall be made and documented.”

Requirements for Documents – 92K ISO 9001:2000 requires a minimum of 6 procedures. Quality Manual 4.2.3 Control of Documents 4.2.4 Control of Records 8.2.2 Internal Audit 8.5.2 Corrective Action 8.5.3 Preventive Action

Requirements for documents 13485 ISO 13485:2003 requires a minimum of 19 procedures! Quality Manual 4.2.3 Control of Documents 4.2.4 Control of Records 6.2.2 Competence, awareness and training 7.3 Design and Development 7.4.1 Purchasing Process 7.5.1.2 Installation activities (if applicable) 7.5.1.3 Servicing activities (when required) 7.5.3.1 Identification 7.5.3.2 Traceability 7.5.5 Preservation of Product 7.6 Control of Measuring and Monitoring Devices 8.1 Statistical Techniques (if used) 8.2.2 Internal Audits 8.3 Control of nonconforming product 8.4 Analysis of Data 8.5 Improvement 8.5.2 Corrective Action 8.5.3 Preventive Action

13485:2003 Certification = certification to ISO 9000:2000 ISO 13485 is a stand alone standard It is based on ISO 9001:2000. Primary objective of ISO13485 is to facilitate harmonized medical device regulatory requirements. Includes some particular requirements for medical devices and excludes some of the ISO 9001:2000 requirements These exclusions prevent users from claiming conformity with ISO9001:2000!

13485:2003 Registration Oversight bodies include SCC and UKAS Companies do not have to re-structure their documentation to meet 13485:2003 format it would make for more efficient audits if a company did or at least provided a cross-reference of documents from the old standard to the new Certified companies will have 9 months from the release date of ISO 13485:2003 to update to the new revision Companies can be certified to ISO 13485:96 until 12/15/03. Oversight bodies include SCC and UKAS ANSI/RAB developing accreditation scheme second quarter 2002

Certification Options ISO 13485 (8):96 becomes ISO 13485:2003 EN 4600X:94 will be replaced by ISO 13485:2003 There is no such thing as ISO 13488:2003!